Method Article

Finger-stick Blood Sampling Methodology for the Determination of Exercise-induced Lymphocyte Apoptosis

11.4K views

DOI:

10.3791/2595

February 24th, 2011

* These authors contributed equally

In This Article

Summary

Exercise is capable of inducing apoptosis in immune cells. There are various measurement limitations, particularly relating to the amount of time required to isolate and treat a blood sample prior to the assessment. Demonstrated is a rapid and minimally invasive procedure for the analysis of exercise-induced lymphocyte apoptosis.

Abstract

Exercise is a physiological stimulus capable of inducing apoptosis in immune cells. To date, various limitations have been identified with the measurement of this phenomenon, particularly relating to the amount of time required to isolate and treat a blood sample prior to the assessment of cell death. Because of this, it is difficult to determine whether reported increases in immune cell apoptosis can be contributed to the actual effect of exercise on the system, or are a reflection of the time and processing necessary to eventually obtain this measurement. In this article we demonstrate a rapid and minimally invasive procedure for the analysis of exercise-induced lymphocyte apoptosis. Unlike other techniques, whole blood is added to an antibody panel immediately upon obtaining a sample. Following the incubation period, red blood cells are lysed and samples are ready to be analyzed. The use of a finger-stick sampling procedure reduces the volume of blood required, and minimizes the discomfort to subjects.

Protocol

1. Finger-Stick Blood Sampling

  1. Collection of whole blood is typically taken at rest for a baseline measurement (usually following 10-15 min seated rest), during or immediately following an exercise bout, and throughout the post-exercise period (generally from 1-3 hours following cessation of the exercise).
  2. Using Universal Precautions, first sterilize the fingertip with 70% isopropyl alcohol.
  3. Next, puncture the site using an automated lancet or similar device. Although we use a 30-gauge lancet to provide for subject comfort, a larger gauge needle could be utilized.
  4. Wipe away the first drop of blood, and then collect blood int....

Access restricted. Please log in or start a trial to view this content.

Discussion

A minimally invasive sample collection procedure and subsequent analysis is demonstrated for the analysis of both early and late phases of exercise-induced lymphocyte apoptosis. It is also possible to clearly exclude those cells, which are necrotic, and not apoptotic. This procedure overcomes the drawbacks and discomfort associated with invasive venipuncture from the antecubital region at multiple time points prior to, during, and immediately after exercise, or securing a catheter for the duration of the exercise bout. I.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Acknowledgements

This research was supported by a New Faculty Grant from the Faculty Scholarship Council at Western Kentucky University.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Flow Cytometry Binding BuffereBioscience00-4222-26
RBC Lysis BuffereBioscience00-4333-57
Lancet DeviceAccu Check Soft TouchRoche Group
Capillary tubesHeparinized Capillary TubesChase Scientific Glass, Inc.501
CentrifugeGmC LabGilson, Inc.PMS-880
Annexin V-FITC ConjugatedBiovision Inc.K201-400-1
CD4-PE ConjugatedAnti-human, clone RPA-T4eBioscience12-0049-42
CD8-PE ConjugatedAnti-human, clone OKT8eBioscience12-0086-73
CD19-PE ConjugatedAnti-human, clone HIB19eBioscience12-0199-42
7-AAD Viability Staining SolutioneBioscience00-6993-50
CD45RA-APC ConjugatedAnti-human, clone HI100eBioscience17-0458-42
Flow cytometerC6Accuri

References

  1. Simpson, R. J., Florida-James, G. D., Whyte, G. P., Black, J. R., Ross, J. A., Guy, K. Apoptosis does not contribute to the blood lymphocytopenia observed after intensive and downhill treadmill running in humans. Res. Sports Med. 15, 157-174 (2007).
  2. Steensberg, A., Morrow, J., Toft, A. D., Bruunsgaard, H., Pedersen, B. K.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Flow CytometryRed Blood Cell LysisAnnexin V StainingExercise induced ApoptosisWhole Blood AnalysisLymphocyte SubfractionsCapillary Tube SamplingAntibody Panel Incubation

Related Articles