$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Generation of the proximal colon loop (pcLoop)
- Skin preparation: Scrub fur of the abdominal midline with alcohol swabs or gauze sponge soaked with 70% Ethanol. Do not wet a wide area of fur with alcohol to prevent hypothermia.
- Using scissors, perform a midline laparotomy. Make a vertical incision in the middle of the abdomen (about 2 cm in length) and expose the peritoneum. Be careful to not injure intra-abdominal organs.
- Place pre-cut wet cotton gauze over the exposed intra-abdominal cavity.
- Use wet cotton swabs to mobilize and exteriorize the caecum. Carefully place the caecum on the wet cotton gauze.
NOTE: Caecum is localized in the left caudal quadrant of the abdominal cavity in a majority of mice independent of the sex of the animal.
- Using wet cotton swabs, exteriorize the entire ileum and place it on the top of a wet cotton gauze. Identify the proximal colon and the blood supply located in the mesocolon. Mobilize the proximal colon and by using fine tip forceps create the first ligature in an area free of vessels in the mesocolon at about 0.5 cm distal from the caecum (Figure 1B).
- Measure 2 cm from the first ligature and create a second ligature at an area free of blood supply in the mesocolon (Figure 1C).
- Using fine scissors carefully cut next to each ligation to isolate a 2 cm long pcLoop.
NOTE: With fine scissors carefully cut next to each ligation to isolate the 4 cm ileal loop, keeping intact blood supply and mesenteric membrane., it is important to cut off both ends to isolate a pcLoop that is gently cleaned of luminal contents. Carefully cut through the colonic tissue and mesocolon to prevent small vessels from bleeding into the intestinal lumen. If necessary, use thermal cautery to limit bleeding at the incision site.
- Gently flush the pcLoop with warm HBSS to remove feces using a flexible yellow feeding tube attached to 10 mL syringe (Prepare 10 mL syringe filled with warm HBSS and attach to a yellow feeding tube. This syringe will be used for moisturizing exposed tissues during surgery).
- Ligate the two cut ends of the flushed pcLoop using silk suture.
- Use a 1 mL syringe with 30G needle to slowly inject 200 μL of reagent such as FITC-dextrans (1 mg / mL in HBSS). Keep the unused FITC-dextran solution protected from light to prepare the standard curve after serum collection). The pcLoop will inflate causing a moderate distension of the mucosa (Figure 1D).
NOTE: Inject the reagent into the pcLoop lumen on the opposite side of the mesenteric artery. Ensure consistency between animals and create a 2 cm long pcLoop to ensure equal distension of the mucosa.
- Utilize wet cotton swabs to gently place back the ligated pcLoop, ileum and caecum into the abdominal cavity.
- Use a needle holder, anatomical forceps and 3.0 non-absorbable silk sutures with reverse cutting needle to close the abdominal wall.
- Place the animal in a temperature-regulated anesthesia chamber for the incubation period.