Method Article

Bacterial Co-Incubation Assay: A Fluorescence Microscopy-Based Technique to Visualize Intraspecific Bacterial Competition at the Single-Cell Level

July 8th, 2025

In This Article

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Source: Smith, S., et al., Quantification of Interbacterial Competition using Single-Cell Fluorescence Imaging. J. Vis. Exp. (2021).

This video demonstrates a fluorescence microscopy-based method to study bacterial competition at the single-cell level. This method provides insights into the structure and function of bacterial communities.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

1. Coincubate bacterial strains

  1. Choose two bacterial strains for single-cell bacterial competition assays. Here, two strains of V. fischeri are used: a target strain (ES11424) and an inhibitor strain (MJ1125) that is known to kill the target strain using the type VI secretion system on chromosome II (T6SS2)1, which is a contact-dependent killing mechanism.
  2. Transform strains with stable plasmids encoding genes for different fluorescent proteins (e.g., GFP or RFP) to visually distinguish strain types on the microscope. Here, the inhibitor strain is tagged with a GFP-encoding plasmid (pVSV102), and the target strain is tagged with a dsRed-encoding plasmid (pVSV208).
  3. Start with mid-log cultures for both strains, measure and record the optical density at 600 nm (OD600) for all samples.
  4. Normalize each sample to an OD600 = 1.0, which corresponds to approximately 109 CFU/mL for V. fischeri, by diluting the culture with LBS medium.
  5. Mix the two competing strains together at a 1:1 ratio based on volume by adding 30 µL of each normalized strain to a labeled 1.5 mL tube. Vortex the mixed-strain culture for 1-2 s.
    NOTE: In some cases, it may be appropriate to mix cocultures in different ratios. For example, when one strain grows much faster than the other, it may be necessary to start the slower-growing strain at a numerical advantage in order to observe the competition. Optimization may also be required if OD600 does not correspond to similar CFU/mL for both strains.
  6. Repeat step 1.5 for each biological replicate and treatment. In the example shown here, this will result in a total of four mixed-strain tubes: two biological replicates with the wild-type inhibitor strain mixed with the target strain and two biological replicates with the type VI secretion system mutant strain mixed with the target strain.
  7. To ensure competing cells are sufficiently dense for contact-dependent killing in the coincubation on the agar pad, concentrate each mixed culture 3-fold by centrifuging the mixed culture in a standard 1.5 mL centrifuge tube for 1 min at 21,130 x g, discarding the supernatant, and resuspending each pellet in 20 µL LBS medium. Repeat for each sample.
    NOTE: Some bacterial cells are sensitive to damage by centrifugation at high rcf; in such cases, the mixed culture can be centrifuged for 3 min at 4600 x g. Additionally, when quantifying contact-dependent competition, it is important to ensure sufficient cell density on the slide to observe killing. In this article, "crowded" treatments, where killing is observed, had approximately 10 cells/20 µm2.

2. Slide setup

  1. When using an upright microscope, place a ~5 mm2 agarose pad onto a standard 1 mm glass slide. Spot 2 µL of a mixed culture onto the agarose pad and place a #1.5 coverslip (25 mm2) over the spot. See Figure 1B.
  2. When using an inverted microscope, spot 2 µL of a mixed culture onto the #1.5 coverslip bottom of a 35 mm Petri dish and place a ~5 mm2 agarose pad over the coincubation spot. Place a 12 mm circular glass coverslip over the agarose pad. See Figure 1C for an example.
  3. Repeat steps 2.1 or 2.2, depending on the microscope setup used, for the remaining three mixed cultures, resulting in four slides or dishes to be imaged.
  4. Allow slides to sit on the benchtop for approximately 5 min before proceeding. This allows cells to settle on the agar pad and eliminate movement during the imaging process.

3. Fluorescence microscopy

  1. Begin by focusing on cells using white light (phase contrast or DIC) to minimize the effects of photo-bleaching. Based on the average size of a single bacterial cell, use a 60x or 100x oil objective.
  2. Adjust the exposure time and acquisition settings for each channel so that cells are visible in the appropriate channel with minimal background detection.
    NOTE: It is appropriate to use different exposure times for different channels, but the same exposure time should be used across all biological replicates and treatments for a given channel.
  3. For each sample, select at least five fields of view (FOV) and acquire images in each appropriate channel using the acquisition settings (See examples in Figure 2). Save the XY points from each FOV so that the same FOV can be imaged during the final time point. Imaging the same FOV at each time point is necessary to determine the proportion of area occupied by target or inhibitor cells during the analysis steps.
    NOTE: In this example, the fluorescence of GFP is detected using a filter with an excitation wavelength of 467 - 498 nm and an emission filter of 513 - 556 nm and is false-colored green. The Fluorescence of dsRed is detected using a filter with an excitation wavelength of 542 - 582 nm and an emission filter of 603 - 678 nm and is false-colored magenta.
  4. After 2 h, repeat the above step for each sample using the previously saved XY points (Figure 2).
    NOTE: The timing of subsequent images may need to be optimized for organisms with different growth rates or competitive mechanisms.

Access restricted. Please log in or start a trial to view this content.

Results

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Agarose pad setup diagram for microbial culture under cover slip: lab tape, mixed culture.
Figure 1: Agarose pad preparation and slide setup for coincubation assays. (A) Setup for making 2% agarose pads. Five layers of lab tape (green) are wrapped around a cover slip at two points approximately 20 mm apart. Next, warm 2% agarose in mar...

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
1.5 mL Microcentrifuge tubeFisher05-408-129
10 uL single channel pipette
1000 uL single channel pipette
20 uL single channel pipette
200 uL single channel pipette
AgaroseFisherBP165-25Low melting agarose
Cellvis 35 mm DishFisherNC0409658#1.5 cover glass bottom
ChloramphenicolSigmaC0378stock (20 mg/mL in Ethanol); final concentration in media (2 μg /mL LBS)
FIJI image analysis sofwareImageJhttps://imagej.net/Fiji/Downloadsopen-source software
Fisherbrand Cover Glasses: CirclesFisher12-545-81P#1.5 cover glass; 12 mm diameter
Kanamycin SulfateFisherBP906-5stock (100 mg/mL in water, filter sterilize); final concentration in media (1 μg/mL LBS)
Lens Cleaning Tissue PaperFisherS24530
Petri PlatesFisherFB0875713sterile with lid
Razor BladesFisherS65921
Semi-micro CuvettesVWR97000-586
Spectrophotometer
Thermo Scientific Gold Seal Plain Microscope SlidesFisher12-518-100B
Thermo Scientific Richard-Allan Scientific Cover GlassFisher22-050-235#1.5 cover glass, 25 mm2
Type F Immersion OilFisherNC0297589
Upright or inverted fluorescence microscope with camera and imaging softwareImages in this article were acquired on a Nikon TI-2 inverted fluorescent microscope outfitted with an ORCA-Fusion Digital CMOS camera using NIS-Elements software.
Vortex
Water bathUsed to keep agarose warm prior to pipetting
<strong>LBS media</strong>
1M Tris Buffer (pH ~7.5)50 mL 1 M stock buffer (62 mL HCl, 938 mL DI water, 121 g Trizma Base)
Agar TechnicalFisherDF0812-17-915 g (Add only for plates)
DI water950 mL
Sodium ChlorideFisherS640-320 g
TryptoneFisherBP9726510 g
Yeast ExtractFisherBP9727-25 g
<strong>mPBS (marine PBS)</strong>Phosphate buffered saline with marine salts added; used for making agarose pad
10X PBSFisherICN1960454
Instant Ocean Sea SaltInstant OceanSS1-160PAdjust concentration to appropriate salinity; 20 psu used here
Sterile Vacuum Filter UnitsFisherSCGVU01REUsed to filter-sterilize mPBS
Vacuum pumpUsed to filter-sterilize mPBS

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Type Six Secretion SystemSingle Cell ImagingFluorescent ProteinsOptical DensityAgarose PadCoverslip PreparationDIC Imaging