1. Nuclear extraction and cell fixation
- Prepare stock solutions: 0.2 M PIPES (pH 6.8), 5 M NaCl, 2 M sucrose, 1 M MgCl2, 0.1 M EGTA (pH 8.0).
- Prepare nuclear extraction buffer (NEB): dissolve 10 mM PIPES (pH 6.8), 100 mM NaCl, 300 mM sucrose, 3 mM MgCl2, 1 mM EGTA (pH 8.0) and 0.5% (v/v) Triton X-100 in ddH2O. Mix until dissolved completely.
- Prepare 4% (v/v) paraformaldehyde (PFA): dissolve 10 mL of 16% PFA aqueous solution in 30 mL PBS. Mix until dissolved completely.
- At appropriate time point (t=0, 1, 2, 4, 16 h), wash cells twice with 1 mL of PBS. Remove PBS completely.
- Add 200 μL of NEB to each well for cell nuclei extraction (cytoplasm is degraded, only nucleus remains) (Figure 1). Incubate for 2 minutes at room temperature and remove completely.
NOTE: Do not exceed 2 minutes.
- Wash cells with 1 mL of PBS. Remove PBS completely. Add PBS carefully, cells are very fragile at this step.
- Add 200 μL of 4% (v/v) PFA to each well for cell fixation. Incubate for 10 minutes at 4 °C. Remove PFA completely.
- Add 1 mL of PBS.
NOTE: Cells can be stored in PBS at 4 °C.
2. Immunofluorescence staining
- Prepare blocking solution: dissolve 5% BSA (w/v) in PBS and add 0.3% (v/v) Triton X-100. Mix until completely dissolved.
- Prepare dilution buffer: dissolve 1% BSA (w/v) in PBS and add 0.3% (v/v) Triton X-100. Mix until completely dissolved.
- For blocking, add 200 μL of blocking solution to each well. Incubate for 2 hours at room temperature or 16-18 hours at 4 °C.
NOTE: If goat antibody will be used, add 5% goat serum to blocking solution.
- Dilute primary antibody in dilution buffer (1:500; see Table 1 for antibodies list) and vortex until well mixed.
NOTE: If goat antibody is used, add 1% goat serum to dilution buffer.
- In a humidity/incubation box, adhere a piece of parafilm. Add 10 μL of primary antibody (in a single drop). Align one edge of the coverslip with the drop and slowly lower onto the parafilm, for the liquid to spread throughout (avoid bubbles if possible). Incubate for 2 hours at room temperature.
- Wash coverslips three times in PBS for 1 minute.
- Dilute secondary antibody in dilution buffer (final concentration: 2 μg/mL) and vortex until well mixed.
- Apply 10 μL of secondary antibody as described for the primary antibodies. Incubate for 2 hours at room temperature.
NOTE: Protect from light.
Table 1: Antibodies used. List of antibodies used in this study.
| Antibody | Company | Reference | Source |
| 53BP1 | Cell Signaling | 4937 | Rabbit |
| Anti-Mouse IgG H&L (Alexa Fluor 647) | Abcam | ab150103 | Donkey |
| Anti-phospho-Histone H2A.X (Ser139), clone JBW301 | Millipore | 05-636 | Mouse |
| Anti-Rabbit IgG H&L (Alexa Fluor 488) | Abcam | ab150081 | Goat |
- Wash coverslips three times in PBS for 1 minute.
- Wash coverslips with H2O for 1 minute.
- Counterstain DNA with DAPI: apply 10 μL of 300 nM DAPI (as described for antibodies), incubate for 30 minutes at room temperature and then mount onto glass slide with a glycerol based mounting media. Alternatively, add one drop (10 μL) of commercial antifade mounting media containing DAPI onto a slide and apply a coverslip. Gently press the coverslip and remove excess fluid around it with a paper towel.
- Seal coverslips with transparent nail polish and let them dry for 20 minutes.
- Store slides at 4 °C.
3. Image acquisition
- Place a drop of immersion oil onto the 60x objective lens. Use DAPI to locate the nuclei through eye piece.
- For XYZ image acquisition, open acquisition software and select parameters: Scanner type: Galvano; Scanner mode: Roundtrip; Image size: 512×512; PMT mode: VBF; PMT average: frame (4 times); PMT sequential scan: line.
- Select the dye and the detectors:
Channel (CH1), Dye (DAPI), Detector (SD1)
Channel (CH2), Dye (Alexa Fluor 488), Detector (HSD3)
Channel (CH3), Dye (Alexa Fluor 647), Detector (HSD4)
- Select ON in "Z".
- Adjust the live image. Press the Live button on the Live window.
- Adjust the focus and set laser intensity (%), sensitivity (HV), gain and offset on "PMT" tool window.
- Adjust the laser intensity (%): for brightness and bleaching. The higher the laser intensity, the stronger the signal, but the specimen will photobleach.
- Adjust the sensitivity (HV): noise level. The higher the HV, the stronger the signal, but image will be noisy if too high.
NOTE: Always keep voltage constant.
- Adjust the offset: background level.
- Select Start/End (15 slices), for Z stacks.
- Start the acquisition.
- Select the folder to save images. Press the LSM Start button to start acquiring the image. Press the Series Done button to complete the image acquisition.