A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Diffuse Correlation Spectroscopy to Assess Cerebral Blood Flow in a Mouse Model

1K views

July 8th, 2025

In This Article

Abstract

Source: Brothers, R. O., et al. Systems Analysis of the Neuroinflammatory and Hemodynamic Response to Traumatic Brain Injury. J. Vis. Exp. (2022)

In this video, we demonstrate the diffuse correlation spectroscopy technique to measure cerebral blood flow in a mouse model of mild traumatic brain injury.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board

1. Assessment of cerebral blood flow with diffuse correlation spectroscopy

  1. DCS data acquisition
    1. Remove hair on the scalp. Because DCS works best in the absence of hair, it is necessary to remove fur on the head prior to the start of experiments. Typically, hair removal is done 1-3 days prior to the start of the study.
      1. Induce mice with 4.5% isoflurane in 100% oxygen for 45 seconds and maintain with 1-2% isoflurane in 100% oxygen.....

Access restricted. Please log in or start a trial to view this content.

Results

Optical sensor and anesthesia setup; mouse imaging, source-detector pattern; diagram.
Figure 1: Measurement of cerebral blood flow by Diffuse Correlation Spectroscopy. (A) An optical sensor is gently manually held over the right hemisphere to measure blood flow in an anesthetized mouse. (B) Representative sensor placement on the right .......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Depilatory creamAmazonNair
DiH<sub>2</sub>OVWRVWRL0200-1000
Hardware Autocorrelator Boardwww.correlator.comFlex05-8ch
Isoflurane 250 mLMED-VET INTERNATIONALRXISO-250
Kimwipe (11.2 x 21.3 cm)VWR21905-026
Laboratory vortex mixerVWR10153-838
LabViewNational InstrumentsLabVIEW
Luminex 200, HTS, FLEXMAP 3D, or MAGPIX with xPONENT softwareLuminex Corporation
R Programming Language
RStudiowww.rstudio.com
Sonicator
1 m acrylic guide tubeMcMaster-Carr49035K85
4 photon counting avalanche photodiodePerkin-ElmerSPCM-AQ4C-IO
400 um multimode source fiberThorlabs Inc.FT-400-EMT
54 g boltAce Hardware0.95 cm basic body diameter, 2 cm head diameter, 10.2 cm length
780 nm single mode detector fiberThorlabs Inc.780HP
852 nm long-coherence length laserTOPTICA PhotonicsiBeam smart

Tags

Traumatic Brain InjuryNear-Infrared LightAvalanche PhotodiodeAutocorrelatorCerebral Blood Flow IndexOptical Sensor PlacementData Acquisition