| 27G1/2" needles | BD biosciences | 305109 | |
| 30G1/2" needles | BD biosciences | 305106 | |
| 5 mL polystyrene round-bottom tube 12 x 75 mm style | Corning | 352054 | |
| BD 1 mL Tuberculin Syringe Without Needle | BD biosciences | 309659 | |
| BD FACS array bioanalyzer | BD Biosciences | | For purity check of eluted CD34+ cells |
| BD FACS array software | BD Biosciences | | Software to analysis acquired CD34+ cell on FACS array |
| BD FACS lysing solution | BD Biosciences | 349202 | To lyse red blood cells |
| BD LSR II | BD Biosciences | | Instrument for acquisiton of flow cytometry samples |
| BD Vacutainer Plastic Blood Collection Tube | BD biosciences | BD 367874 | To collect Cord blood |
| Bovine Serum Albumin | Sigma-aldrich | A9576 | |
| CD34 MicroBead Kit, human | Miltenyi Biotec | 130-046-702 | For isoation of CD34+ HSPC |
| CD34-PE, human | Miltenyi Biotec | 130-081-002 | Antibody used for purity check of eluted CD34+ cells |
| Cell counting slides | Bio-rad | 1450015 | |
| ChargeSwitch gDNA Mini Tissue Kit | Thermofisher scientific | CS11204 | For extraction of genomic DNA from ear piece |
| Cotton-tipped applicators | McKesson | 24-106-2S | |
| DMSO (Dimethyl sulfoxide) | Sigma-aldrich | D2650-5X5ML | |
| Extension set Microbore Slide Clamp(s) Fixed Male Luer Lock. L: 60 in L: 152 cm PV: 0.55 mL Fluid Path Sterile | BD biosciences | 30914 | Attached to dispensing pippet and to load with HSPC and HEP suspesion |
| FACS Diva version 6 | BD Biosciences | | Flow cytometer software required for acqusition of sample |
| Fetal Bovine Serum (FBS) | Gibco | 10438026 | |
| FLOWJO analysis software v10.2 | FLOWJO, LLC | | Flow cytometry analysis software |
| Ganciclovir | APP Pharmaceuticals, Inc. | 315110 | Prescripition drug |
| Greiner MiniCollect EDTA Tubes | Greiner bio-one | 450475 | |
| Hepatocytes thawing medium | Triangle Research Labs | MCHT50 | |
| Horizon Open Ligating Clip Appliers | Teleflex | 537061 | To hold the ligating clips |
| Human hepatocyte | Triangle Research Labs | HUCP1 | Cryopreserved human hepatocytes, induction qualified |
| Iris Scissors, Straight | Ted Pella, Inc. | 13295 | |
| Lancet | MEDIpoint | Goldenrod 5 mm | |
| LS columns | Miltenyi Biotec | 130-042-401 | Used to entrap CD34+ microbeads (positive selection) |
| Lymphocyte Separation Medium (LSM) | MP Biomedicals | 50494 | For isoation of lymphocytes from peripheral blood |
| MACS MultiStand | Miltenyi Biotec | 130-042-303 | Holds Qudro MACS seperator and LS columns |
| McPherson-Vannas Micro Dissecting Spring Scissors | Roboz Surgical Instrument Co. | RS-5605 | Used to make an incision on skin to expose spleen |
| Micro Dissecting Forceps | Roboz Surgical Instrument Co. | RS-5157 | To hold and pull out spleen from peritoneal cavity |
| Mouse CD45-FITC | BD Biosciences | 553080 | Mouse-specific |
| PBS (Phosphate Buffered Saline) | Hyclone | SH30256.02 | |
| Qudro MACS separator | Miltenyi Biotec | 130-090-976 | holds four LS columns |
| RPMI 1640 medium | Gibco | 11875093 | |
| StepOne Plus Real Time PCR | Applied Biosystems | | Instrument used to genotype |
| Stepper Series Repetitive Dispensing Pipette 1ml | DYMAX CORP | T15469 | Used to dispense HSPC and HEP supension in controlled manner |
| TaqMan Gene Expression Master Mix | Thermofisher scientific | 4369016 | |
| TC20 automated cell counter | Bio-rad | 1450102 | |
| TK-NOG mice | | | Provided by the Central Institute for Experimental Animals (CIEA, Japan; Drs. Mamoru Ito and Hiroshi Suemizu) |
| Treosulfan | Medac GmbH | | Provided by Dr. Joachim Baumgart (medac GmbH) |
| Trypan Blue | Bio-rad | 1450022 | |
| Vannas-type Micro Scissors, Straight, 80mm L | Ted Pella, Inc. | 1346 | Used to make an incision on skin to expose spleen |
| Weck hemoclip traditional titanium ligating clips | Esutures | 523700 | To ligate the spleen post-injection |