A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Applying Noise Currents to Medial Vestibular Nucleus Neurons Using Whole-Cell Patch-Clamp Technique

666 views

July 8th, 2025

In This Article

Abstract

Source: Stefani, S. P., et al. Stochastic Noise Application for the Assessment of Medial Vestibular Nucleus Neuron Sensitivity In Vitro. J. Vis. Exp. (2019).

This video demonstrates a protocol involving the application of subthreshold noise currents to medial vestibular nucleus neurons using the whole-cell patch-clamp technique to study the impact of the noise currents on neuronal sensitivity to electrical stimuli.

Protocol

All procedures involving sample collection have been performed in accordance with the institute's IRB guidelines.

1. Animals

NOTE: Mice were obtained from the Australian Rodent Centre (ARC; Perth, Australia) and held at the Medical Foundation Building Animal Facility at the University of Sydney.

  1. Maintain the mice on a standard 12 h light/dark cycle with environmental enrichment.
  2. Use male and female C57BL/6 mice (3–5 weeks old) for all experiments.

2. Preparation of Solutions

  1. Prepare 1 L of....

Access restricted. Please log in or start a trial to view this content.

Results

Average firing rate bar graph; statistical analysis of neuronal activity, spikes/s, error bars.
Figure 1: Objective determination of 12 pA threshold. Firing rates for less than 12 pA (3 and 6 pA) and more than 12 pA (18 and 24 pA) were pooled and averaged. These averages were then analyzed using an ANOVA and statistical significance between sham and &#.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
CaCl2ScharlauCA01951000Used for ACSF and sACSF
D-(+)-GlucoseSigmaG8270Used for ACSF and sACSF
EGTASigmaE0396-25GUsed for K-based intracellular solution
HEPESSigmaH3375-25GUsed for K-based intracellular solution
KClChem-supplyPA054-500GUsed for ACSF, sACSF and intracellular solution
K-gluconateSigmaP1847-100GUsed for K-based intracellular solution
Mg-ATPSigmaA9187-500MGUsed for K-based intracellular solution
MgClChem-supplyMA00360500Used for ACSF and sACSF
Na3-GTPSigmaG8877-100MGUsed for K-based intracellular solution
NaClChem-supplySO02270500Use for ACSF and intracellular solution
NaH2PO4.2H2OAjaxAJA471-500GUsed for ACSF and sACSF
NaHCO3SigmaS5761-1KGUsed for ACSF and sACSF
SucroseChem-supplySA030-500GUsed for sACSF
IsofluraneHenry Schein1169567762Used for anaesthetising mice
EQUIPMENT
Borosilicate glass capillariesWarner instrumentsGC150T-7.51.5mm OD, 1.16mm ID, 7.5cm
length
Data acquisition softwareAxographUsed for electrophysiology and analysis
Friedmen-Pearson RongeursWorld precision instruments14089Used for dissection
Micropipette pullerNarishigePP-830Used for micropipette
Multiclamp amplifierAxon instruments700BUsed for electrophysiology
pH meterSper scientific860033Used for internal solution
Standard pattern scissorsFST14028-10Used for dissection
Sutter micromanipulatorSutterMP-225/MUsed for electrophysiology
Upright microscopeOlympusBX51WIUsed for electrophysiology
VibratomeLeicaVT1200Used for slicing brain tissue

Tags

Noise Current ApplicationNeuronal Sensitivity AnalysisElectrophysiology RecordingMicropipette TechniqueMembrane Seal FormationCurrent Clamp RecordingsFiring Rate MeasurementLinear Regression Analysis