Method Article

Monitoring the Brain Cortex with a Multi-Electrode Array in Response to Seizure-Inducing Agents

July 8th, 2025

In This Article

Abstract

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Source: Lu, H. C., et al. Direct-current stimulation and multi-electrode array recording of seizure-like activity in mice brain slice preparation. J. Vis. Exp. (2016).

In this video, the effects of transcranial direct-current stimulation (tDCS) on brain slices containing the anterior cingulate cortex (ACC) and thalamus regions are investigated, using a multi-electrode array (MEA) to measure electric signals. By delivering electric pulses and infusing seizure-inducing drugs, the study investigates the ACC response to seizures.

Protocol

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.

1. Preparing Experimental Solution and Equipment for MEA (Multielectrode Array) Recording

  1. Prepare artificial cerebral spinal fluid (aCSF; 124 mM NaCl, 4.4 mM KCl, 1 mM NaH2PO3, 2 mM MgSO4, 2 mM CaCl2, 25 mM NaHCO3, and 10 mM glucose, bubbled with 95% O2 and 5% CO2).
  2. Use two types of MEA probes: 6 x 10 planar MEA and 8 x 8 MEA. The former probe covers the region that comprises the cortex, striatum, and tha....

Access restricted. Please log in or start a trial to view this content.

Results

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Thalamus stimulation setup with MEA circuit diagram, brain slice, perfusion for neural recording.
Figure 1: Preparation of the Thalamocingulate Slice and MEA Recording System Setup. (A) MT-ACC slice procedure (a) Remove the brain and (b) transfer to cool oxygenated aCSF. (c) Make two parasagittal cuts from the midline. (d) Side view of the medial part .......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,
No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
IsofluraneHalocarbon Products CorporationNDC 12164-002-254%
aCSF (total:1 L):
D(+)-GlucoseMERCK1.08337.100010 mM
Sodium hydrogen carbonateMERCK1.06329.050025 mM
Sodium chlorideMERCK1.06404.1000124 mM
(+)-Sodium L-ascorbate, >=98%SIGMAA4034-100G0.15 g/2 c.c
Magnesium sulfate, anhydrous, ReagentPlusSIGMAM7506-500G2 mM
Calcium chloride dihydrateMERCK1.02382.10002 mM
Sodium dihydrogen phosphate monohydrateMERCK1.06346.10001 mM
Potassium chlorideMay & Baker LTD Dagenham EnglandMS 76164.4 mM
(+)-BicucullineTOCRIS1305 µM in aCSF
4-AminopyridineTOCRIS940250 µM in aCSF
VibratomeVibratomeSeries 1000Block slicing into 500 µm thick slices
Multielectrode array (MEA) probes: 6 x 10 planar MEAMulti Channel Systems60MEA500/30iR-Ti-pr MEAS 6x10electrode diameter, 30 µm; electrode spacing, 500 µm; impedance, 50 kΩ at 200 Hz
Multielectrode array (MEA) probes: 8 x 8 MEAAyanda Biosystems60MEA200/10iR-Ti-pr MEAS 8x8pyramidal-shaped electrode; diameter, 40 µm; tip height, 50 µm; electrode spacing, 200 µm; impedance, 1,000 kΩ at 200 Hz
A 60-channel amplifier was used with a band-pass filter set between 0.1 Hz and 3 KHz at 1,200X amplificationMulti-Channel SystemsMEA-1060-BC
MC Rack software at a 10 KHz sampling rateMulti-Channel SystemsSoftware for data collect and recordings
control of a pulse generatorMulti-Channel SystemsSTG 1002
slice anchor kits and hold-downsWarner InstrumentsSHD-26H/10; WI64-0250
Peristaltic Pump-minipuls3GilsomMINIPULS3perfusion rate : 8 ml/min
Isolated stimulatorA-M SystemsModel 2100intensity of ±350 μA , duration of 200 μsec
Tungsten electrodeA-M Systems575300placed in thalamus

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Tags

Multi Electrode ArrayBrain Slice PreparationTranscranial Direct Current StimulationSeizure Inducing AgentsAnterior Cingulate CortexThalamus RegionElectric Signal RecordingDrug Perfusion MethodStimulating Electrode PlacementArtificial Cerebrospinal Fluid

Related Articles