A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Whole-Cell Patch Clamp Recordings on Intact Rat Dorsal Root Ganglia

1.3K views

⸱

July 8th, 2025

In This Article

Abstract

Source: Gong, K.,et al. Patch Clamp Recordings on Intact Dorsal Root Ganglia from Adult Rats. J. Vis. Exp. (2016)

This video demonstrates the examination of sensory neuron excitability in the dorsal root ganglia using the patch clamp technique to measure the rheobase and membrane potential, analyzing the neurons' responses to incremental current injections.

Protocol

All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.  

1. Patch Clamp Recordings

  1. Place the electrode solution (see Table 1) on ice to prevent degradation. Fill the glass patch pipette with filtered intracellular solution (syringe filter, pore size: 0.2 µm) and place the pipette in the head stage pipette holder. Apply gentle, positive pressure to the pipette through a 5 ml syringe by displacing the plunger about 1 ml before lowering the pipette into the bath solution.
    Note: Th....

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Glass pipetteSutterBF150-110-7.5
AnchorHavard apparatus64-0250stabilize the DRG to avoid drift.
Peristaltic pumpWPI
Pipette pullerSutterP97
AmplifierMolecular devicesAxopatch 200B
DigitizerMolecular devices1440D
MicroscopeNIKONFN600
Micro-manipulatorSutterMPC200
Carbogen (95% O2, 5% CO2)Local Medical Gas supplier