Variations of the testing protocol
Modulation of startle responses have been studied for many decades in both humans and animals. A huge variety of different protocols have been used in the past. The current protocol is a relatively short and easy to perform test that works well in rodents, however, depending on the focus of interest and previous work on the respective questions, it might be useful to vary this protocol in order to obtain data that is comparable to previous relevant studies. A common variation includes the addition of more prepulse intensities ranging from 3 db above background noise to 20 db above noise. Also, the habituation block can be split into a short block of 5-10 stimuli before the PPI block, plus a third block of 5-10 stimuli after the PPI block18-20. A thorough study of the existing literature before designing a testing protocol is therefore essential.
Differences between species and strains
Startle response amplitudes and the amount of habituation differ considerably between single animals of the same specie and strain, whereas PPI seems to be relatively consistent. Mice do generally move more (voluntarily) during testing, which might be one reason why their data generally has a higher variability than rat data. Mice do also not habituate as well as rats. Differences between individual mouse or rat strains can be huge21-24, and it might be necessary to adapt stimulus parameter to the startle behavior of a specific strain in order to get optimal results. It should be avoided to use the same equipment to test both mice and rats. If it is inevitable, equipment should be thoroughly cleaned with ethanol.
Gain factors
Sometimes there are huge differences in individual startle responses within a group. In order to measure PPI and habituation, the baseline or first startle responses should be ideally covering the most part of the dynamic range of the measuring system. Overshoots are detrimental, since they lead to a systemic error, typically underestimating the amount of habituation or PPI. If startle responses are too small, however, modulations may be occluded by noise. Startle systems allow for the adjustment of a gain factor that amplifies the platform signal. Gain factors can be adjusted by displaying two or three startle stimuli during the last acclimation session (gain =1), however, one should keep in mind that they change the absolute startle response amplitude and therefore do not allow for a comparison of absolute startle amplitudes anymore. In order to avoid this drawback, the three startle responses that are used for gain factor adjustments could be used for determining the baseline startle magnitude. Alternatively, gain factors could be adjusted only after block I, so that the block II startle responses cover most of the dynamic range, while block I can be used for determining the baseline startle response.
Habituation versus sensitization
Habituation decreases the startle response amplitudes. This is opposed by a sensitization, which leads to an increase of startle responses upon repeated presentation25. Habituation and sensitization are two independent processes affecting the same behavior26. In order to measure habituation, sensitization should be minimized. Animals sensitize if a stimulus is aversive, thus too loud startle stimuli should be avoided for habituation measurements, for review see27. Stress, anxiety and fear do also increase startle responses28,oppose habituation and affect PPI18. Animals should therefore be well handled and acclimatized to the startle testing apparatus. Also, animal holders that are too small and physically restrain the animals are counterproductive, since they induce stress in the animals29.
Fixed versus randomized ITI
Common startle protocols use either a fixed inter-trial interval (ITI) typically of 20 or 30 sec or a variable interval that pseudorandomizes on values between 15 and 30 sec. The advantage of a randomized ITI lies in the fact that the animal cannot predict the time point of the next stimulation. It has been shown that e.g. attention to the prepulse augments its efficacy in suppressing startle responses13, 30. Measuring PPI with a fixed ITI may therefore also probe for attention processes. ITIs below 15 sec should be avoided in order to prevent effects caused by muscle fatigue and refractory periods of muscle responses.
Intensity and duration of prepulse
We use a very short prepulse of 4 ms duration in this protocol. Many other studies use a 20 ms prepulse. In order to be able to vary the interstimulus intervals (ISIs) and to measure also very short intervals, this short prepulse was introduced. The efficacy of the prepulse seems to be attenuated by its short duration as compared to a 20 ms prepulse of the same volume. We therefore use relatively loud prepulses of 75 and 85 dB. Whereas a 85 dB startle stimulus (20 ms) can be above threshold, a 85 dB prepulse (4ms) does normally not elicit startle responses. However, it is important to evaluate whether there are no startle responses elicited by the prepulse itself that would cause muscle fatigue and refractory states during the startle stimulus. Some treatments that disrupt PPI have shown to enhance prepulse sensivity31 (indicating the PPI disruption is not due to a loss of acoustic sensitivity), however, this could not be found in schizophrenic patients32Evaluations of the prepulse sensitivity can be done either by analyzing the platform data in the period between prepulse or startle pulse or by including prepulse alone trials in block II.
Different ISI versus different prepulse intensities
PPI in humans was originally measured at an ISI of 100 ms, where its effect is at its maximum7. In rats and mice PPI is at its maximum at 30-50 ms ISI, probably due to the smaller size of the brains33. In recent years it has become apparent that different transmitter and transmitter receptors are engaged in a serial manner in order to exert the fast but long-lasting inhibition of startle3, 34. Depending on the system affected, drugs or genetic manipulations might therefore affect PPI only at specific ISIs. We therefore recommend varying the ISI between 30 ms and 100 ms. This also allows recent studies to be compared to former studies that used 100 ms ISI only. The 85dB prepulse leads to a very robust maximum PPI of around 90%. Please be aware that this PPI cannot necessarily be augmented without running into a ceiling effect. PPI induced this way also seems to be rather robust, however, it is significantly disrupted e.g. by 1 mg/kg amphetamine. We recommend using a second prepulse of 75 dB which leads to 50-60% PPI only. This PPI can be augmented (e.g. by 1 mg/kg s.c. nicotine), and seems to be more vulnerable to genetic and pharmacological manipulation in general, however, it also seems to be more variable and inconsistent even within a subject. Former studies have used a huge variety of prepulse intensities and have often shown effects of treatments on PPI with specific prepulse intensities and no affect on PPI with other prepulse intensities. Thorough studies of the existing literature is therefore essential before choosing prepulse intensities and interstimulus intervals.
Combination with injections systemic/stereotaxic
Habituation and PPI testing is often performed in combination with systemic or stereotaxic injections. It is evident that in these experiments animals of a control group receive control vehicle injections. The injection procedure itself, however, might be very stressful for an animal, leading to a higher anxiety level and a potentiation and/or sensitization of the startle response (see above). It is therefore recommended to control for the effect of the injection procedure itself as well. If habituation is studied, prior injections might be a major obstacle. In order to alleviate the animal's anxiety, animals should be returned to their home cage for as long as possible before tested (without the drug wearing off). Injections should also be administered by an experienced person, in order to minimize the impact of the procedure on the animal. If stereotaxic injections are made through chronically implanted cannulae, the surgeon who implants the cannulae should avoid rupturing the rats' eardrums with the pointed ear bars. This might lead to hearing deficits. Blunt ear bars or ear cuffs that do not rupture eardrums are available for all stereotaxic devices. When rats are handled after surgery, the dust caps or dummies should be manipulated each time, so that the animals get used to it.
Acoustic startle as a hearing test
Finally it should be noted that i/o functions of acoustic startle and PPI can serve as a simple hearing test for rats and mice 35-37. Hearing deficits shift an i/o function to the right. Once PPI is established for a rat or mouse strain, animals can also be tested with variable prepulse intensities. If an animal is deaf or cannot hear the prepulse as loud as a control animal, it will display no or less PPI than control animals. On the other hand, an observed PPI deficit could always be caused by a hearing deficit, thus an i/o startle test or comparisons of baseline startle responses are crucial controls.