Investigating therapeutic approaches to a clinical model of illness necessitates the ability to accurately perform hemodynamic monitoring, thus requiring vascular access. In our model of sepsis, arterial catheterization provides systemic pressure monitoring and venous catheterization allows for the application of standard clinical therapy. Standard therapy for sepsis includes the infusion of antibiotics to treat bacterial infection and the infusion of fluids and vasopressors to maintain arterial pressure within the desired range. Both catheters are used for blood sampling. In this design, the application of programmable infusion pumps with automatic triggering of the vasopressor infusion rate based on real-time mean arterial pressures is an advance over the clinical setting which requires manual titration by the medical staff and in the pre-clinical setting makes the use of this treatment modality possible for studying large numbers of animals.
Some complications were experienced early in the development of the model. These included partial occlusion of both arterial and venous catheters from over tightening, ties on PU2 and PU3 components, (1-2%); misplacement of jugular venous catheter into a small branch, (<1%); unexplained sudden death after recovery (no pulmonary thrombus or other organ damage evident), (1-2%) resolved by keeping isoflurane concentration 2-3.5% with O2 flow rate of 2 L/min. Other common surgical complications of hemorrhage, local infection and self-inflicted damage were not observed. Once surgical proficiency is attained, each procedure should be able to be completed in no more than 15 min. The rate of success measured as a healthy recovery and patent catheters, can be expected to exceed 90% once fully trained. An additional animal is included in each study to minimize the loss of data and the total number of animals needed and account for a failed catheter that may be “infusion only” or mortality due to complications.
The most critical step in this procedure is the design and placement of the catheters. The materials need to be soft at the tip so as not to pierce the vessel wall without crimping too easily. The body of the catheter has to be stiffer (than the tip) to be able to advance into the vessel sufficiently and be secured in place. Figure 1 shows the 3 diameters of tubing that are connected for the arterial catheter and 2 different diameter tubing connected for the venous catheters. These components are slid within each other to reduce catheter diameter at the tip and are glued together with anchors added to ensure placement of the catheter in the vessel or heart is maintained.
Once recovered and connected to the swivel and tether, the MAP and CVP waveforms should appear similar to the data represented in Figure 2. To maintain arterial catheter patency during monitoring, an hourly heparin saline flush (0.05 ml) should be performed. Continuous infusion maintains the venous catheter patency. During line connection and flush, close attention must be paid to insure there are no air bubbles in the line. An air bubble of ≥0.1ml can result in an embolism in the lung, brain or other organs. Hemodynamic waveforms are recorded and analyzed over the course of the study. When compressing time in the x axis, Figure 3 shows the changes in MAP and CVP over the course of 1 hr as well as the changes in rate and effect of vasopressor infusion.
The procedure has several potential limitations. In our studies, the catheters remain patent for up to 11 days. It is unknown how long the catheters would remain patent beyond this period. To fit the catheters as described, there is a minimum vascular size, which roughly correlates with rodent weight, requiring animals enrolled in this study to be greater than 200 g. The use of a smaller catheter diameter would result in increasing resistances to flow reducing patency. Attaining central venous pressure measures requires precise catheter placement in the atrium sufficient to account for size and growth during the study period and can be a challenge.
Once mastered, arterial and vascular catheterization can provide the basis for a wide variety of rodent models requiring hemodynamic monitoring, blood sampling, and infusion of fluids or therapies while minimizing any pain and distress during instrumentation or handling once recovered. In fact, in conjunction with a previous JOVE publication10 describing catheterization of the femoral vein, we have successfully performed this model with 3 implanted catheters.