Chemical synaptic transmission between neurons is a major mechanism of communication in the nervous system. It relies on the release of neurotransmitters through a dynamic cycle of vesicle fusion and retrieval at the presynaptic site. Many of the proteins involved in vesicle dynamics have been identified; however, their specific contribution to the phenomenon remains to be clarified1.
Our understanding is partly limited by the fact that the most widely used assays for exo/endocytosis are not always the most appropriate. Several studies related to vesicle fusion and dynamics rely on electrophysiological techniques. This technique provides an optimal temporal resolution and is excellent for investigating the initial fusion of vesicles to the plasma membrane but is unable to detect many of the underlying molecular events that support presynaptic function. Electron microscopy, on the other side, provides the finest morphological description of each singular step, but the dynamic aspect of the event cannot be captured, because samples must be fixed in order to be analyzed.
The advent of new optical recording techniques2,3, in combination with advances in fluorescent molecular probes development4-6, enables the visualization of exocytic processes in live cells, thus providing new levels of information about the synaptic structure and function.
Initial studies exploited activity-dependent styryl dyes (FM1–43 and related organic dyes)7,8. State-of-the-art imaging techniques employ pH-sensitive variants of the Green Fluorescent Protein (GFP) (pHluorin) tethered to luminal vesicles proteins9. These probes are normally switched off when present in the vesicles because of the low luminal pH. After fusion with the plasma membrane, the vesicle interior is exposed to the neutral extracellular space, the pH abruptly increases, relieves the proton-dependent quenching of pHluorin and the fluorescent signal rapidly appears. As the change in pHluorin is faster than the fusion event, by monitoring fluorescence increases, vesicle fusion with the membrane can be measured and analyzed. Because surface pHluorin-tagged molecules are endocytosed, the fluorescence signal subsequently returns to basal level, therefore the same construct may be used also to monitor vesicle recycling9.
While the vesicle-tagged pH-sensor ensures the visualization only of those vesicles that really fuse with the plasma membrane, imaging at high spatial and temporal resolution is required to describe in details the steps involved in the exo/endocytic processes. The optical technique that provides the necessary spatio-temporal resolution is total internal reflection fluorescence microscopy (TIRFM), an application of fluorescence microscopy10.
Total internal reflection occurs at the interface between the glass cover-slip and the sample. When the light path reaches the glass cover-slip with an incident angle larger than the critical angle, the excitation light is not transmitted into the sample but is completely reflected back. Under these conditions, an evanescent light wave forms at the interface and propagates in the medium with less optical density (the sample). As the intensity of the evanescent field decays exponentially with distance from the interface (with a penetration depth of about 100 nm) only the fluorophores in closest proximity to the cover-slip can be excited while those further away from the boundary are not. In cells transfected with GFP-constructs, this depth corresponds to proteins expressed on the plasma membrane or in vesicular structures approaching it. As fluorophores in the cell interior cannot be excited, the background fluorescence is minimized, and an image with a very high signal/background ratio is formed11.
Several characteristics make TIRFM the technique of choice for monitoring vesicles dynamics. The perfect contrast and the high signal-to-noise-ratio allow the detection of very low signals deriving from single vesicles. Chip-based image acquisition in each frame provides the temporal resolution necessary to detect highly dynamic processes. Finally, the minimal exposure of cells to light at any other plane in the sample strongly reduces phototoxicity and enables long lasting time-lapse recording12.
Data analysis remains the most challenging and crucial aspect of this technique. The simplest way to monitor vesicle fusion is to measure the accumulation of reporter fluorescent proteins at the cell surface, over time13. As fusion increases, net fluorescence signal increases as well. However, this method may underestimate the process, particularly in large cells and in resting conditions, because endocytosis and photobleaching processes offset the increase in fluorescence intensity due to vesicle exocytosis. An alternative method is to follow each single fusion event14. This latter method is very sensitive and can reveal important details about the fusion mechanisms. However, it requires the manual selection of single events, because completely automated procedures to follow vesicles and to register the fluctuation of their fluorescent signals are not always available. Observation of vesicle dynamics requires sampling cells at high frequency. This generates a large amount of data that can hardly be analyzed manually.
The proposal of this paper is to optimize the TIRFM imaging technique for monitoring the basal and stimulated neurotransmitter release in the SH-5YSY neuroblastoma cell line, and to describe, step-by-step, a procedure developed in the laboratory to analyze data, both at whole-cell and single-vesicle levels.