Mouse pneumonectomy is a commonly employed model of compensatory lung growth. This procedure can be used in conjunction with lineage tracing or transgenic mouse models to elucidate underlying mechanisms.
In humans, disrupted repair and remodeling of injured lung contributes to a host of acute and chronic lung disorders which may ultimately lead to disability or death. Injury-based animal models of lung repair and regeneration are limited by injury-specific responses making it difficult to differentiate changes related to the injury response and injury resolution from changes related to lung repair and lung regeneration. However, use of animal models to identify these repair and regeneration signaling pathways is critical to the development of new therapies aimed at improving pulmonary function following lung injury. The mouse pneumonectomy model utilizes compensatory lung growth to isolate those repair and regeneration signals in order to more clearly define mechanisms of alveolar re-septation. Here, we describe our technique for performing mouse pneumonectomy and sham pneumonectomy. This technique may be utilized in conjunction with lineage tracing or other transgenic mouse models to define molecular and cellular mechanism of lung repair and regeneration.
Den huvudsakliga funktionen av lungan är att tillhandahålla syre och koldioxidutbytet mellan en organism och atmosfären. Hos människor, en värd av medfödda och förvärvade förhållanden leder till minskad lung ytarea som resulterar i försämrad lungfunktion. Även en mängd terapier såsom inhalerade kortikosteroider, bronkdilaterare, extra syrgas och kronisk mekanisk ventilation används för att lindra konsekvenserna av nedsatt lungfunktion 1-3, skulle den ideala terapin för dessa förhållanden främjar återväxt av funktionell lungvävnad – dvs, lunga regeneration.
Däggdjursvävnadsregenerering är väl dokumenterade. Den afrikanska Spiny Mouse kan regenerera stora hudområden utan ärrbildning 4. Den distala falangen hos människa kan regenerera efter skada eller amputation 5-7. Efter Pneumonectomy (PNX), förekommer kompensationslungtillväxt hos möss 8, råttor 9, görgs 10, och människor 11. Per definition innebär kompensatorisk lungtillväxt inte bara expansion av befintliga luftrum, men åter septumbildning dessa förstorade luftrum med utbyggnaden av den tillhörande mikrocirkulation 12. Genuttryck analys har visat att denna modell rekapitulerar många av de signal händelserna lungutveckling 13. Fyra veckor efter mus PNX, är alveolära yta ekvivalent med den för skenopererade djur 14. I detta manuskript, beskriver vi musen PNX och falska PNX förfaranden.
Vi har lämnat den mest detaljerade beskrivningen av musen PNX och mus sken PNX förfaranden som hittills rapporterats. Vi har gjort läsaren medveten om flera av de vanligaste fallgroparna att utredarna lära förfarandet möter vanligt, och vi har skisserat flera tekniker som utvecklats av vårt laboratorium för att mildra effekterna av dessa fallgropar. Andra laboratorier som använder denna modell kan ha utvecklat andra modifikationer teknik eller använda olika instrument. Vid bedömningen skillnader i tekniker, k…
The authors have nothing to disclose.
The authors would like to acknowledge the Cincinnati Children’s Hospital Division of Veterinary Services for their assistance. This manuscript was supported by the National Institutes of Health K12 HD028827. Anna Perl PhD taught the authors this surgical procedure.
Name of the reagent | Company | Catalogue number | Comments (optional) |
6-inch Vascular Clip Applicator | Teleflex Medical (WECK) | 137062 | |
Horizon Small Titanium Red Clip | Teleflex Medical (WECK) | 1201 | |
Narrow Pattern 12cm Curved Forceps | Fine Science Tools | 11003-12 | |
Curved Serated 10 cm Graefe Forceps | Fine Science Tools | 11052-10 | |
Castroviejo Needle Holder | Fine Science Tools | 12565-14 | |
Straight 9 cm Strabismus Scissors (Blunt Tip) | Fine Science Tools | 14075-09 | |
Straight 8.5 cm Hardened Fine Scissors | Fine Science Tools | 14090-09 | |
Straight, Blunt Tip Cohan-Vannas Spring Scissors | Fine Science Tools | 15000-12 | |
Skin Glue | Gluture | 32046 | |
22 ga angiocatheter | |||
24 ga angiocatheter | |||
3 mL luer lock syringe | |||
4 short retractors | |||
2 long retractors | |||
5-0 Prolene on curved cutting needle | Ethicon | 8698G | |
0.5 mL syringe on 27 ga needle | |||
Normal Saline | |||
Buprenorphine | |||
Press-n-Seal Wrap | Glad Products Company | ||
12 inch X 12 inch cork board stack | Office Depot | ||
70% Ethanol | |||
Betadine | |||
Mouse Ventilator | Hugo Sachs Elektronnik | Minivent Type 845 | |
Isoflurane Vaporizer | OHMEDA | Excel 210 SE | |
artificial tear ointment | puralube | NDC: 17033-211-38 |