The mouse is now the primary animal model of a variety of lung diseases. In models of emphysema or fibrosis, the essential phenotypic changes are best assessed by measuring the changes in lung elasticity. Although there are many ways to measure elasticity, the classical method is that of the total pressure-volume (PV) curve measured from residual volume (RV) to total lung capacity (TLC). This measurement has been made on adult lungs from nearly all mammalian species dating back almost 100 years1-3. Such PV curves also played a major role in the discovery and understanding of the function of pulmonary surfactant in fetal lung development4-7. Despite the PV curve’s importance as a measurement of the lung’s phenotype, there has been no standardized way to perform this measurement. It has been done simply by inflating and deflating the lung with discrete steps (waiting a variable time for equilibration after each) or with pumps that can continuously inflate and deflate the lung. The PV curve is often done over a volume range between zero and some user-define lung capacity, but the time duration of each pressure volume loop reported by different labs has been extremely variable, varying from a few sec8 to hr2. Some investigators refer to this total lung PV curve as static or quasistatic, but these are qualitative terms that offer little insight, and they are not used here. In addition, the PV curve has not been widely reported in the mouse, despite the fact that it can provide useful information on the macroscopic effects of structural changes in the lung.
Several issues have resulted in variability in PV curve acquisition including: 1) the rate of inflation and deflation; 2) the pressure excursions for inflation and deflation; and 3) the means to determine an absolute lung volume measurement. In the method present here, a rate of 3 ml/min was chosen as a compromise, being not too short as to reflect the dynamic elasticity associated with normal ventilation and not too slow as to make the measurement impractical, particularly when studying large cohorts. Since a nominal total lung capacity in a C57BL/6 healthy mouse is on the order of 1.2 ml9, this rate typically allows two complete closed PV loops to be done in about 1.5 min.
In the extended literature where PV curves have been reported, the peak inflation pressure used has been extremely variable, varying from as low as 20 to over 40 cm H2O. Part of this variability may be related to species, but a primary goal of setting the upper pressure limit for PV curves is to inflate the lung to total lung capacity (TLC), or maximal lung volume. The TLC in humans is defined by the maximal voluntary effort an individual can make, but unfortunately this can never be duplicated in any animal model. Thus, the maximal volume in experimental PV curves is determined by a maximal pressure arbitrarily set by the investigator. The goal is to set a pressure where the PV curve is flat, but unfortunately the inflation limb of a mammalian lung PV curve is never flat. So most investigators set a pressure where the inflation curve begins to flatten substantially, typically 30 cm H2O. In the mouse, however, the PV curve is even more complex with a double hump on the inflation limb, and where this inflation limb is often still rising steeply at 30 cm H2O10, so 30 is not a good end point for the PV curve. For this reason, we use 35 cm H2O as the pressure limit for the mouse PV curve, which is a pressure at which the inflation limbs of all strains we have examined begin to flatten.
Since the PV curve itself is very nonlinear, the appearance of a PV loop will depend on the volume from where the curve starts. Some commercial ventilators allow users to do large PV loops, starting from FRC, but if the FRC volume is unknown then it is impossible to interpret changes in such PV curve with any pathology, since these changes could simply result from a change in starting volume, and not structural alterations in the lung. Thus without an absolute volume measurement, PV curves are almost impossible to interpret and thus have little utility. Although, there are several ways to measure lung volumes, these are often cumbersome and require special equipment. In the simple approach described here, the PV curve starts at zero volume after an in vivo degassing procedure.
In summary, this paper demonstrates a straightforward method to standardize lung PV curve measurement in the mouse lung, and defines several metrics that can be calculated from this curve that are linked to lung structure. The PV curve thus provides a pulmonary function test that has direct application in being able to detect phenotypic structural changes in mice with common lung pathologies such as emphysema and fibrosis.