Microvascular imaging is a rapidly growing field with many potential clinical applications.2 For example, oncologists are using microvessel imaging to determine the extent of tumor angiogenesis, yielding valuable information concerning the state of the tumor and insight into possible treatment options. 34 However, nailfold capillaroscopy is perhaps the most cost efficient and widely applicable form of microvascular imaging. Researchers are using video nailfold capillaroscopy to study blood flow rates and investigate capillary morphology.5 6 Both video and still-picture nailfold capillaroscopy are adjuncts to care for diagnosing and treating Raynaud’s phenomenon and various connective tissue diseases such as systemic sclerosis.2
Nailfold capillaroscopy has various potential cardiovascular applications as well. Current research using nailfold capillaroscopy suggests that diabetes mellitus Type 1 and Type 2 patients exhibit a high prevalence of abnormal capillary morphology, yet have unchanged capillary densities compared to non-diabetic individuals.7-8 Capillaroscopy has also been studied experimentally in hypertension. Structural capillary rarefaction leading to a reduced capillary density has been demonstrated in hypertensive individuals compared to non-hypertensive individuals.9-10 In contrast to these older hypertensive patients (mean age 40 and above) who exhibit structural rarefaction, more recent research has demonstrated that younger hypertensive patients (mean age under 40 years old) have functional rarefaction without structural rarefaction.11 This suggests that functional rarefaction occurs before and may progress over time to structural rarefaction.
Interestingly, hypertensive patients treated with specific antihypertensive drugs such as Perindopril/Indapamide displayed normal capillary density and endothelial function after treatment, while those treated with ACE (angiotensin-converting-enzyme) inhibitors or diuretics maintained a low capillary density despite comparable blood pressure control.12 This suggests that some antihypertensive medications may normalize capillary density by reversing the capillary rarefaction caused by hypertension. In addition, other researchers have shown that a reduction in salt intake leads to reversal of both functional and structural capillary rarefaction in hypertensive individuals.13
Despite the various potential clinical applications of this technology, there is little standardization in technique for quantitating capillary density images.2 To date, researchers have found that capillary density results are reproducible from both an intra-observer and inter-observer perspective only if the exact same area is being counted each time. 1,14 15 Of note, previous researchers have largely performed capillary counts manually using the naked eye, 9 16 17 18 which is a slow and subjective process.
Standardized, computer based algorithms for quantitation of capillary images theoretically provide more efficient and reproducible data analysis with less subjectivity, facilitating clinical applications of capillaroscopy. Some researchers have indeed used computer-based programs to quantitate the data from nailfold capillaroscopic pictures. 1,6 19 20 However, only one publication to date describes reliability of a complex software program available for quantitating capillaroscopy data,1 and this program is complicated as previously noted above by the requirement to count the exact same visual field. Here, we present a simpler, reliable protocol for quantitating capillaries using a standardized algorithm which allows for the use of multiple visual fields. The use of multiple visual fields not only simplifies the procedure, but also permits the assessment of normal biological variation in capillary count.
The aim of this study is to describe a reproducible and efficient computer based algorithm which standardizes the capillary quantitation process. While these methods are not fully automated they require very little user input, and provide rapid and reliable quantitation of the pictures.