Microperfusion in the vasculature entails establishing controlled flow of an artificial perfusate of known composition via a micropipette in a blood vessel usually less than 40 µm in diameter. The perfused vessel remains within its normal tissue environment and is perfused with the animal’s blood up to the time of cannulation. When used in conjunction with a range of video imaging or fluorometric techniques, in situ microperfusion enables measurement of water and solute flows across the walls of microvessels under conditions where the driving forces for these flows are known and the permeability properties of the vascular wall can be directly evaluated. Further, by controlling the composition of the fluid surrounding the microvessel in the tissue (perfusate and superfusate), the regulation of microvessel permeability and exchange can be investigated by enabling the endothelial cells forming the microvessel wall to be exposed to a variety of experimental conditions (agonists, modified perfusion conditions, fluorescent indicators to measure intracellular composition and signaling) for precisely measured periods of time (sec to hr). In addition, ultrastructural or cytochemical evaluations of key cellular molecular structures regulating the barrier can be investigated in the same microvessels in which permeability is directly measured. The approach thereby forms a bridge between investigation of the cellular and molecular mechanisms to modify endothelial barrier function in cultured endothelial cell monolayers and investigation in intact microvessels. See the following reviews for further evaluation1-6.
A limitation of microperfusion is that it can be used only in microvascular beds that are thin, transparent and have sufficient structural integrity to enable cannulation with a glass micropipette. While early investigations used frog microvessels in mesentery and thin cutaneous pectoris muscle7,8, by far the most commonly used preparation in mammalian models is the rat mesentery9-15. Most investigations have focused on acute changes in vascular permeability studied over periods of 1-4 hr, but more recent investigations have been extended to measurements on individual vessels 24-72 hr after an initial perfusion12,16. The recently developed CRISPR technology, which promises to make more genetically modified rat models available for studying vascular permeability regulation17 should enable the methods described in this communication to be applied in venular microvessels of the mesentery in these important new rat models.
The method requires an inverted microscope equipped with a custom built microscope stage large enough to hold both the animal preparation and at least three micromanipulators used to position microtools close to the perfused vessel and to align a perfusion micropipette with the vessel lumen. For example a custom platform for an x-y microscope stage (about 90 × 60 cm) can be fabricated from a 1 cm thick steel plate with a rust-proof coating. The stage is attached to an engineering index table or two dove-tail slides mounted at right angles and supported on Teflon pillars or ball transfers for movement in the horizontal plane. A typical rig (see Figure 2) has much in common with the microscope and micropositioning equipment used for a range of intravital microcirculation experiments such as those to measure single vessel blood flow and hematocrit, local oxygen delivery by blood perfused microvessels, regulation of vascular smooth muscle tone, and the local microvascular accumulation of fluorescent tracers injected into the whole circulation.18-26
The fundamental aspect of the technique is the measurement of volume flow (Jv) across a defined surface area (S) of the microvessel wall. To accomplish this via the modified Landis technique described herein a simple inverted microscope is adequate. A small video camera is mounted on the image port and the video signal, with an added time base, is displayed on a video monitor and recorded either in digital form on a computer or as a digital or analog signal on a video recorder. Once the microvessel is cannulated the portion of the microvessel visible to the camera can be changed by moving the stage and manipulators as a unit without disrupting the cannulation.
Measurement of transvascular flows may also be combined with more detailed investigations using a sophisticated fluorescence microscope with appropriate filters such as rigs used for measurements of solute permeability, fluorescent ratio monitoring of cytoplasmic calcium or other cellular mechanisms, and confocal imaging 6,12,13,27. A key advantage of all microperfusion approaches is the ability to make repeated measures, on the same vessel, under controlled change of driving force such as hydrostatic and oncotic pressures, or induced change in vessel responses to inflammatory conditions. The most common design is a paired comparison of measured hydraulic conductivity (Lp) on the same vessel with the vessel first perfused via a micropipette filled with a control perfusate and the red cell suspension to establish a baseline permeability state, then with a second pipette with the test agent added to the perfusate. Multiple cannulations are possible with the cycle repeated after reperfusion with the control pipette.
The present protocol demonstrates the cannulation and microperfusion of a venular vessel in rat mesentery to record water fluxes across the microvessel wall and measure the Lp of the vessel wall, a useful index of the permeability of the common pathway for water and solutes across the intact endothelial barrier. The procedure is called the modified Landis technique because the original Landis principle of using the relative movement of red cells as a measure of transvascular fluid exchange after perfusion is blocked is preserved28, but the range of experimental conditions (e.g., the hydrostatic and albumin oncotic pressure differences across the microvessel wall) available after microperfusion is far greater than in uncannulated blood perfused microvessels8,29.