All procedures were approved by the ethical committee of the university hospital of the KU Leuven and each subject gave a written informed consent prior to participation.
1. 3D Motion Tracking: Configuration and Data Acquisition
- Ensure that the individual sensors are fully charged (Figure 1A). This step takes about 1 hr but can be performed on the days prior to the actual measurements. Follow the manufacturer's charging protocol.
- MT Manager — Data acquisition2:
- Enable the wireless connection with the sensors and specify the desired sample rate (Wireless Configuration > Enable all wireless masters).
Note: To allow for an accurate characterization of the pedestrian behavior, a sampling rate of at least 60 Hz is advised. The individual sensors record 3D linear acceleration, angular velocity (earth) magnetic field and atmospheric pressure data.
- Activate the operational mode and initiate the measurement mode: make slow movements with the sensors for about 1 min (Wireless Configuration > Start measurement on all wireless masters).
- Display inertial and magnetic data of all active sensors (View > Display > Inertial Data). Make sure that, while stationary, the orientation of the sensor does not chance.
Note: A changing orientation of the stationary sensor would indicate a magnetically disturbed environment and, thereby, inaccurate orientation information.
- Orientation reset: Apply an object/heading reset (Object/heading reset > Reset orientation) to define the global reference frame of the experiments (Figure 1B) 2.
- Place the sensor as close as possible to the body center of mass (CoM) located at the level of the fifth lumbar vertebrae (Figure 1C). Fasten a single sensor tightly and robustly onto each participant with specially designed click-in full body straps (Figure 1C).
- Record data as required.
- Load the records of interest (open file), specify the export settings (Tools > Preferences > Exporters) and export the acceleration (and orientation matrix) data for subsequent analysis2 (File > Export).
2. Force Plate: Setup and Configuration
Note: The present step discusses the application of a force plate to register the GRFs. In the case that a walking/running person is involved, a series of force plates or an instrumented treadmill is to be used to register the loading induced by subsequent steps3, the protocol itself is analogous.
- Ensure that the force plate is securely fixed to the laboratory floor (Figure 2).
- Configure the device and acquisition settings4 (NDI Open Capture > Data > Device Settings > Settings). Select the proper "gain" and "sample rate". Configure and check the external trigger settings, if required4.
- Choose the gain and sample rate in accordance with the desired accuracy and the involved loading type. For the present application, use a gain of 128 (Maximum Force 4,879 N) and a sample rate 200 Hz.
- Start and end each trial with an empty force plate: Tare the force plate when empty (NDI Open Capture > Data > Device Settings > Settings > Tare).
- For verification purposes: Place a known weight on top of the force plate before and after each trial.
Note: In the present application a mass of 5 kg is used, however, the use of another well-known rigid mass (> 2 kg) can equally serve this verification test.
- Record and save the GRF data as required. Export the GRFs for subsequent analysis4.
3. Measurement of the Structural Accelerations
Note: The present steps aim to collect the structural vibrations at one or more relevant locations on the structure. The present application employs GeoSIG GMS recorders (Figure 3) to register the structural accelerations. Other sensor types with proper characteristics for the involved application, can be equally applied.
- Ensure that the individual sensors are fully charged. This step can take several hours but can be performed on the days prior to the actual measurements. Follow the manufacturer's charging protocol.
- Install the sensors on the desired locations of the primary structure: level the sensors and, if necessary, provide proper fixation to the primary structure (e.g., by using magnets).
Note: given the high mass of the individual GMS recorders (> 6 kg) and the involved low-frequency oscillations (< 6 Hz), no additional fixation was necessary in this case.
- For GeoDAS Data acquisition5: Configure and enable the wireless GMS network and connection with the sensors5. Check time settings and synchronization settings (if necessary) (right click on the sensor > More information).
- Position the sensors on the desired location and level them in agreement with the global reference frame.
- For GeoDAS Data acquisition5: Export the recorded data for subsequent analysis (right click on the sensor > Instrument Control > Send a request > User request > GETEVT5).
4. Experiments in a Controlled Laboratory Environment
- Configure / Setup 3D motion tracking (as discussed in section 1).
- Configure / Setup force plate (as discussed in section 2).
- During operation: visually check the real-time measurements of both the wireless inertial sensors and the force plate to verify their operational mode.
- Ask the participant to step onto the force plate and stand still for at least 30 sec: this allows to identify the weight of each individual.
- Configure the metronome signal: select the desired rhythm, i.e., fundamental forcing frequency.
Note: The metronome signal can be easily configured using free online or smartphone applications.
- Start recording the data of both the force plate and the wireless inertial sensors.
- Ask the participant to initiate the desired activity: walking, jumping or bobbing at the (targeted pacing) rate as indicated by the metronome signal (see Figure 4).
- Record the chosen number of loading cycles, e.g., steps, jumps or bobbing cycles. Ask the participant to get off the force plate.
Note: For validation purposes it is advised to consider some additional recording time in these unloaded conditions. In literature, there is no clear consensus about the minimum number loading cycles required to characterize the cycle-to-cycle variabilities6. Based on experience and the work presented in [6], the study presented here considers 60 consecutive cycles whereby the first and last five loading cycles are excluded from the further analysis to exclude irregularities in the loading pattern at the start and end of the trial.
5. Experiments In Situ
- Configure / Setup the network of 3D inertial sensors that track the motion of the participants (see section 2 and Figure 5).
- Configure / Setup the GMS network of wireless accelerometers that register the structural accelerations (see section 4).
- During operation: (visually) check the real-time measurements of the wireless inertial sensors to verify their operational mode.
- Define a clear protocol that allows to synchronize the involved measurement systems, if required.
Note: This step is necessary when the involved data acquisition systems do not allow for direct synchronization due to the lack of a trigger or common channel. The latter is the case for the wireless measurement systems applied in the in situ experiments (5.1 and 5.2). Therefore, a clear protocol has been adopted on site that allows to synchronize the datasets offline. In the present application, the involved measurement systems are synchronized through registration of an identical event, i.e., impact, at the beginning and end of each trial, registered by at least one sensor of each of the involved measurement systems. Properly aligned time vectors are subsequently obtained through offline alignment of these events.
- Configure the metronome signal: in situ, the use of a megaphone to amplify the targeted beat is required.
- Collect a sufficient number of trials to check the repeatability of the experiment. Based on experience, the authors recommend to record at least 3, or preferably 4, trials.
6. Data Analysis
- Pre-process the raw data of the involved equipment as required: Apply the proper filters to remove undesired influences such as irrelevant high-frequency contributions and measurement noise, and retain the relevant time window according to manufacturer's protocol.
Note: The filtering characteristics should be chosen in accordance with the application. In the present study, the MATLAB Signal Processing Toolbox7 is applied to perform a low-pass filtering with a cut-off frequency at 20 Hz for all involved signals.
- For each participant: Compute the discrete Fourier transform of the registered accelerations of the CoM using MATLAB Signal Processing Toolbox7 and identify the average loading frequency as the frequency of the dominant peak of the fundamental harmonic in the obtained spectrum.
- Identify the time in between any two nominally identical events of the load cycles using the method detailed in [3] or the lc_timing tool of the PediVib MATLAB toolbox8
- Load the data vector (lc_timing > Load).
- Specify the sampling rate and estimate the average loading frequency. Specify the relevant time window, if required. Save the identified timing of the nominally identical events, i.e., load cycles (lc_timing > Save).
- Compute the average loading frequency as the inverse of the average time in between the subsequent load cycles (as identified in 6.3).
- For the experiments in the laboratory: Apply the procedure detailed in 6.3 for both the resulting ground reaction forces and the accelerations registered at the CoM of each individual.
Note: This step serves as validation for the procedure as applied for the in situ experiments where the GRFs cannot be measured directly. The method detailed in [3] shows how the time variant pacing rate of the pedestrian can be identified by characterizing the relation between the accelerations registered near the CoM of the individual and the consequent GRFs.
- For the experiments in situ: Apply the procedure detailed in 6.3 for the accelerations registered at the CoM of each individual.
7. Simulation and Analysis of the Structural Response
Note: The subsequent steps are performed using MATLAB7. The structural response is computed using the PediVib toolbox, a MATLAB toolbox developed by the authors8 (Figure 6): the human-induced forces are determined through application of the generalized load models of defined by Li et al.9 (walking) and Bachmann et al.1 (jumping, running and vandal loading), and the structural model is formulated in modal coordinates10. The accompanying manual includes tutorials that clearly illustrate the following steps.
- Simulation of the structural response
- Define the modal parameters of the test structure: Natural frequencies, modal damping ratios, mass-normalized modal displacements, coordinates of the corresponding nodes (PediVib > Structural parameters > New). Visually check the modal input information (PediVib > Structural parameters > View).
- Define the characteristics of the pedestrian and the corresponding induced loads: load type, weight, walking path/location, average pacing rate, onset of each load cycle (PediVib > Single pedestrian > New). Run and save the simulated structural response for the involved participants. Visually check the results (PediVib > Single pedestrian > View).
- Compute the total structural response through superposition of the individual responses, i.e., summation of the corresponding vectors, and compare the result with the measured structural response, e.g., by creating a figure which displays the measured and simulated structural response.