| (3-Aminopropyl) triethoxysilane (APTES) | Acros Organics | 919-30-2 | Used to make 2% APTES solution |
| Plasma Cleaner Pico | Diener | Model 1 | Cleans surfaces and allows for bonding of PDMS to glass |
| d-Desthiobiotin (DSB) | Sigma | D20655 | Used as the releasing mechanism in the cellular capture surface. |
| dimethyl sulfoxide (DMSO) | British Drug Houses (BDH) | BDH1115-1LP | Dissolves the DSB into solution |
| 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) | Thermo-Scientific | 5g: 22980 25g: 22981 | Activates carboxylic acids and allows binding of proteins to glass surface. |
| uncoated 8-well culture slide | BD Falcon | Case of 24: 354118 Case of 96: 354108 | Used in cellular experiments involving Zeiss fluorescence microscope such as initial capture and release quantification experiments |
| Glass bottom 24-well plates | MatTek | P24G-0-13-F | Used in cellular experiments involving the plate reader such as antibody and cellular titration experiments |
| Mercaptoethanol | Science Lab | 60-24-2 | Used to quench reaction between EDC and DSB |
4-Morpholinoethanesulfonic acid hydrate (MES Hydrate 99%) | Fisher Scientific | AC172590250 | Used to make 0.1 M MES Buffer for use in EDC reaction |
| Precision Oven | Thermo Scientific | 11-475-153 | Used in curing of PDMS and APTES layer. |
| Titramax 1000 Shaker | Heidolph | 13-889-420 | Used to ensure even distribution of APTES on surfaces. |
| 1x Streptavidin 5 mg [e7105-5mg] | Proteo Chem | 9013-20-1 | Biotin-binding protein. May cause irritation. |
| 5 cm Glass Dish | Fisher Scientific | 08748A | Used in HUVEC studies as well as future profiling studies. |
| 14 cm Petri Dish with Cover | Sigma-Aldrich | Z717231 | Used to hold samples being functionalized and transport them. |
| MCF7-GFP cells | Cell Biolabs | AKR211 | Stored in liquid nitrogen |
| RAW264.7 mouse macrophages | ATCC | TIB-71 | Gifted to us from Smith lab at the University of Illinois. Stored in liquid nitrogen. |
| TrypLE | Life Technologies | 12605036 | Stored in 100 ml at room temperature |
| Dulbecco’s modified Eagle medium | Cell Media Facility at School of Chemical Sciences at UIUC | 50003PC | Supplier: Corning |
| Nonessential amino acids | Cell Media Facility at School of Chemical Sciences at UIUC | 25-025-CI | Already added into DMEM by facility. Supplier: Corning. |
| Cell scraper | Fisher Scientific | 12-565-58 | Small 23 cm 50 pack |
| Cell Dissociation Solution | Corning | MT-25-056CI | Used to lift cells non-enzymatically for the use in cell experiments |
| Hemacytometer | Hausser | 02-671-54 | Used to count cells for quantification of cell solutions and capture and release effectivity. |
| Biotin | Amresco | 58-85-5 | Used to release cells from surface. |
| HBSS | Created from Recipe | N/A | Used to keep cells alive in suspension as well as wash surfaces of non-specific binding. Adapted from Cold Spring Harbor Protocols: In 500 ml, use 4 g NaCl, 0.2 g KCl, 0.0402 g Na2PO4•7H2O, 0.03 g KH2PO4 and 0.5 g glucose. Add DI water to get to 500 ml, filter, and then refrigerate. |
| HLA-ABC Antibody | BioLegend | 311402 | Antibody used to capture MCF7gfp cells |
| hIgG Antibody | BioLegend | HP6017 | Antibody used to capture MCF7gfp cells |
| MCF7 GFP cells | Cell Biolabs | AKR-211 | Luminal Breast Cancer line that has been transfected with green fluorescent protein. |
| Assorted Conicals | Thermo-Scientific | 15mL: 12-565-268 | 50/15 ml plastic conicals for storing solutions and aliquots. |
| Mini-Tube Rotators (End over End Mixer) | Fisher Scientific | 05-450-127 | Used to incubate antibody and mix other cellular solutions in order to mix |
| Axiovert 200M (Fluorescence Microscope) | Zeiss | N/A | Zeiss Axiovert 200 M inverted florescence microscope. |
| Zeba Desalting columns | Thermo-Scientific | PI-87770 | Used to purify newly biotinylated antibodies after the use of the Biotinylation Kit. Instructions provided at: http://www.funakoshi.co.jp/data/datasheet/PCC/89894.pdf |
| EZ Link Sulfo NHS Low Weight Biotinylation Kit | Thermo- Scientific | | Used to biotinylate antibodies to allow them to integrate with the capture surface |
| Plate Reader | BioTek | Synergy HTX Multimode Reader | Used to quantitatively measure fluorescent intensity in the titration experiments. |