This study describes the surgical procedures and experimental techniques for performing awake cystometry in a freely moving mouse. In addition, it provides experimental evidence to support its optimization and standardization.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
* These authors contributed equally
This study describes the surgical procedures and experimental techniques for performing awake cystometry in a freely moving mouse. In addition, it provides experimental evidence to support its optimization and standardization.
Awake filling cystometry has been used for a long time to evaluate bladder function in freely moving mice, however, the specific methods used, vary among laboratories. The goal of this study was to describe the microsurgical procedure used to implant an intravesical tube and the experimental technique for recording urinary bladder pressure in an awake, freely moving mouse. In addition, experimental data is presented to show how surgery, as well as tubing type and size, affect lower urinary tract function and recording sensitivity. The effect of tube diameter on pressure recording was assessed in both polyethylene and polyurethane tubing with different internal diameters. Subsequently, the best performing tube from both materials was surgically implanted into the dome of the urinary bladder of male C57BL/6 mice. Twelve-hour, overnight micturition frequency was recorded in healthy, intact animals and animals 2, 3, 5, and 7 days post-surgery. At harvest, bladders were assessed for signs of swelling using gross observation and were subsequently processed for pathological analysis. The greatest extent of bladder swelling was observed on day 2 and 3, which correlated with behavioral voiding data showing significantly impaired bladder function. By day 5, bladder histology and voiding frequency had normalized. Based on the literature and evidence provided by our studies, we propose the following steps for in vivo recording of intravesical pressure and voided volume in an awake mouse: 1) Perform the surgery using an operating microscope and microsurgical tools, 2) Use polyethylene-10 tubing to minimize movement artifacts, and 3) Perform cystometry on post-operative day 5, when bladder swelling resolves.
Filling cystometry (FC) is a diagnostic method that involves placing a catheter into the urinary bladder to record pressure during slow bladder filling. First introduced in 1927 as a clinical diagnostic method to evaluate lower urinary tract function, it has remained widely used.1 In research applications, FC can be used to test bladder function in healthy and diseased animal models and to study the effects of pharmacological agents. Rodent animal models are commonly used to investigate lower urinary tract function.2 In this group of mammals, FC was first developed for use in rats.3 Here, the meth....
Access restricted. Please log in or start a trial to view this content.
Animals were housed in the University of Vermont Animal Care Facility according to institutional guidelines. All animal experiments were carried out in accordance with the National Institutes of Health guide for the care and use of laboratory animals.
1. Intravesical Tube Implantation
Access restricted. Please log in or start a trial to view this content.
There was no significant difference between the tubing materials and diameters in the consistency of pressure rise and fall within the system during tube occlusion. Bladder wall swelling post intravesical tube implantation was significant for both polyethylene (PE) and polyurethane (PU) materials. On day 2, severe submucosal swelling developed. It occupied half the cross-section of the bladder, leading to obstruction of the lumen. On day 5, the edema resolved completely, leaving the submu.......
Access restricted. Please log in or start a trial to view this content.
Optimal material and size of intravesical tubing
To determine the effect tubing diameter has on pressure recordings, we tested different microfluidic tubes; PE50 (0.58 mm ID), polyurethane PU027 (0.4 mm ID), PE25 (0.46 mm ID), and PE10 (0.28 mm ID). For each tube, pressure was recorded with the infusion pump running at 1 mL/h, while rapidly moving the tube vertically from 0 to 30 cm. Initial in vivo experiments attempted to use PE50 tubing, but were unsuccessful due to the size of tubing compared.......
Access restricted. Please log in or start a trial to view this content.
The authors have nothing to disclose.
This study was funded by the Department of Surgery University of Vermont, Danish Council for Independent Research, and by the Odense University Hospital.
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| Polyethylene (PE) 10 tubing | Instech | BTPE-10 | Fits 30G connectors/plugs |
| Polyethylene (PE) 50 tubing | Instech | BTPE-50 | Fits 22G connectors/plugs |
| 22 G single channel stainless steel swivel | Instech | 375/22 | |
| High Carbon Steel Utility Extension Spring (9/64" OD) | Grainger | 1NAH1 | Protects PE50 tubing - Cut to length |
| 22 G connector | Instech | SP22/12 | |
| Yutaoz Professional Hot Melt Adhesive Glue Gun | Yutaoz | Use low temperature setting (100 °C) - Any hot melt glue gun with an adjustable temperature range will work | |
| Surebonder DT-2010 all purpose glue stick | Surebonder | Any all purpose hot glue will work | |
| Dumont #5 curved microforceps | World Precision Instruments | 500232 | |
| Dumont #7 curved microforceps | World Precision Instruments | 14188 | |
| Mini dissecting scissors - straight | World Precision Instruments | 503240 | |
| Micro mosquito forceps (12.5 cm) | World Precision Instruments | 500451 | |
| Dissecting scissors - straight | World Precision Instruments | 14393 | |
| Castroviejo Needle Holder | World Precision Instruments | 503258 | |
| Isoflurane, USP | Phoenix | 2%, 1 L/min flow rate | |
| Buprenorphine | 0.05 mg/kg | ||
| 0.9% Sodium Chloride Irrigation, USP | Baxter | ||
| 6-0 Ethilon black monofilament, non-absorbable suture | Ethicon | Bladder tie | |
| 6-0 Vicryl violet braided, absorbable suture | Ethicon | Muscle suture, running | |
| 6-0 Prolene blue monofilament, non-absorbable suture | Ethicon | Skin suture, vertical mattress, buried interrupted | |
| KD Legato 210 infuse/withdraw pump | KD Scientific | 1.5 mL/hr | |
| Disposable pressure transducer | Digitimer | NL108T2 | |
| Pressure Amplifier | Digitimer | NL108A | |
| Power1401-3 data acquisition interface | Digitimer | ||
| Spike2 | Cambridge Electronic Design Limited | PC pressure recording software | |
| Leica MZ6 surgical operating microscope (3.2 - 20X) | Leica Microsystems | Magnification |
Access restricted. Please log in or start a trial to view this content.