A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Ovine Lumbar Intervertebral Disc Degeneration Model Utilizing a Lateral Retroperitoneal Drill Bit Injury

11.7K views

⸱

DOI:

10.3791/55753

⸱

May 25th, 2017

 ,  ,  ,  ,  ,  ,  , 

* These authors contributed equally

In This Article

Summary

Intervertebral disc degeneration is a significant contributor to back pain and a leading cause of disability worldwide. Numerous animal models of intervertebral disc degeneration exist. We demonstrate an ovine model of intervertebral disc degeneration, utilizing a drill bit, which achieves a consistent disc injury and reproducible level of disc degeneration.

Abstract

Intervertebral disc degeneration is a significant contributor to the development of back pain and the leading cause of disability worldwide. Numerous animal models of intervertebral disc degeneration have been developed. The ideal animal model should closely mimic the human intervertebral disc with regard to morphology, biomechanical properties and the absence of notochordal cells. The sheep lumbar intervertebral disc model fulfils these criteria. We present an ovine model of intervertebral disc degeneration utilizing a drill bit injury through a lateral retroperitoneal approach. The lateral approach significantly reduces the incision and potential morbidity associated with the traditional anterior approach to the ovine spine. Utilization of a drill-bit method of injury affords the ability to produce a consistent and reproducible injury, of precise dimensions, that initiates a consistent degree of intervertebral disc degeneration. The focal nature of the annular and nucleus pulposus defect more closely mimics the clinical condition of focal intervertebral disc herniation. Sheep recover rapidly following this procedure and are typically mobile and eating within the hour. Intervertebral disc degeneration ensues and sheep undergo necropsy and subsequent analysis at periods from eight weeks. We believe that the drill bit injury model of intervertebral disc degeneration offers advantages over more conventional annular injury models.

Introduction

Lower back pain is the leading cause of disability worldwide1. Lumbar intervertebral disc degeneration associated discogenic pain is considered a significant contributor to lower back pain2. There is an increasing demand for reliable animal models of intervertebral disc disease for broadening the understanding of the degenerative process and for the investigation of potential therapies.

Numerous animal models of intervertebral disc degeneration exist3. Animals models used in the investigation of degenerative disc disease range in size from mice4,....

Access restricted. Please log in or start a trial to view this content.

Protocol

The protocol detailed in this manuscript follows the animal care guidelines of Monash University Animal Ethics. Animal ethics approval for this protocol has been granted by Monash University Animal Ethics. Ethics approval number: MMCA/2014/55

1. Sheep Preparation

NOTE: Ewes aged two to four years were used.

  1. Fast sheep for 18 h prior to anesthesia. Provide animals with access to water until 6-12 h prior to operation19.
  2. Sedate animals by intravenous injection of medetomidine hydrochloride (0.015-0.020 mg/kg) to facilitate transfer to operating suite.
    NOTE: The me....

Access restricted. Please log in or start a trial to view this content.

Results

Pre-operatively, sheep underwent baseline 3T magnetic resonance imaging (MRI) for assessment of underlying intervertebral disc morphology and degeneration. Sheep underwent additional intra-operative lateral radiography for confirmation of intervertebral disc level and calculation of disc height index. A pre-operative sagittal plane slice from 3T MRI and an intra-operative radiograph are demonstrated in Figure 1.

Access restricted. Please log in or start a trial to view this content.

Discussion

This minimally invasive lateral access approach is efficacious and safe with no post-operative herniae, abdominal wound dehiscence or infection observed in this series. Use of the drill bit intervertebral disc injury model with a depth stop provides a reproducible method of inducing a consistent intervertebral disc injury of known dimension (i.e. a 3.5 mm diameter x 12 mm depth injury in this study). In our experience, this method produces a less severe degree of disc degeneration than that observed in conventio.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors declare they have no competing financial interests to disclose.

Acknowledgements

Dr. Chris Daly is the recipient of the Foundation for Surgery Richard Jepson Research Scholarship. The authors would like to thank Dr. Anne Gibbon, Dr. Dong Zhang and the staff of Monash Animal Services, Monash University for their assistance with animal surgery and care.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Medetomidine Hydrochloride (10 mL Injection)Therapon/ZoetisPFIDOM10Multiple suppliers: Zoetis/Ilium
ThiopentoneTroyTriothiopentoneMultiple suppliers: Neon Laboratories, Jagsonphal Pharmaceuticals
Isoflurane (2 - 3 % in oxygen)BaxterAHN3636Multiple suppliers: Baxter/VetOne
Amoxicillin parenteralGlaxoSmithKlineJO1CA04Multiple suppliers: GlaxoSmithKline/Merck
Bupivacaine (0.5% Injection 20 mL)Pfizer005BUP001Multiple suppliers: Pfizer/AstraZeneca
PVD Iodine SolutionJurox61330Multiple suppliers: Jurox/Orion
Chlorhexidine 5%w/vJuroxChlorhex C 5L (SCRUB)Multiple suppliers: Jurox/Pfizer
Transdermal Fental Patch (75 μg/h)Janssen-CilagS8-Dur7.5Multiple suppliers: Sandoz
Buprenorphine ivJurox504410Multiple suppliers: LGM Pharma
Atipamezole (Antisedan 0.06 mg/kg - 0.08 mg/kg)ZoetisPFIANT10Multiple suppliers: Ilium
Oster Golden A5 2-Speed ClippersOster078005-140-003Oster
20 mL luer lock syringeTerumo6SS+20LMultiple suppliers: Medshop Australia/Terumo
21 G IV needleTerumoSG3-1225Multiple suppliers:Medshop Australia/Terumo
#4 scalpel handleAustvetAD010/04Multiple suppliers: Austvet/SurgicalInstruments
#22 scalpel baldesAustvet
Gillies tissue forcepsAustvetAB430/15Multiple suppliers: Austvet/SurgicalInstruments
Metzenbaum curved dissecting scissorsAustvetAC101/14Multiple suppliers: Austvet/SurgicalInstruments
Deaver retractorSurgical Instruments23.75.03Multiple suppliers: Surgical Instrument/Austvet
Hohmann retractorAustvetKA173/35Multiple suppliers: Austvet/SurgicalInstruments
Mayo suture scissorsAustvetAC911/14Multiple suppliers: Austvet/SurgicalInstruments
Needleholder 14 cm EliteMedical18-1030Multiple suppliers: EliteMedical/Austvet
CMT 3.5 mm Brad-Point DrillCarbatec516-035-51Multiple suppliers: Southeast Tool/Carbatec
Drill Bit Stop 4 mmDrill Warehouse20121600Multiple suppliers: Amazon
Bosch 10.8 V Cordless Angle DrillGet Tools DirectGWB10.8V-LIBBMultiple suppliers:Bunnings/Get Tools Direct
Autoclavable veterinary drill bagAustVetDRA043-AVAustVet
2-0 absorbable synthetic braided suturesEthiconVCP335HEthicon
3-0 absorbable synthetic braided suturesEthiconVCP232HEthicon
Siemens 3 Tesla Skyra Widebore MRISiemensN/ASiemens
9.4 Tesla Agilent (Varian) MRIAgilent TechnologiesN/AAgilent Technologies
Atomscope HF 200 A RadiogaphRadlink330003AMultiple Suppliers: Radlink/DLC Australia
Veterinary Pulse OximiterDLC 192500AMultiple suppliers: DLC Australi Pty Ltd/AustVet

References

  1. Hoy, D., March, L., et al. The global burden of low back pain: estimates from the Global Burden of Disease 2010 study. Ann Rheum Dis. 73 (6), 968-974 (2014).
  2. Luoma, K., Riihimäki, H., Luukkonen, R., Raininko, R., Viikari-Juntura, E., Lammine, A. Low back pain in relati....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Ovine Intervertebral DiscLateral Retroperitoneal ApproachSheep Lumbar SpineSurgical Injury ModelAnnulus Fibrosus InjuryNucleus Pulposus DefectMRI AnalysisPostoperative Recovery