Summary

This protocol describes the stabilization of the oxygen level in a small volume of recycled buffer and methodological aspects of recording activity-dependent synaptic plasticity in submerged acute hippocampal slices.

Abstract

Even though experiments on brain slices have been in use since 1951, problems remain that reduce the probability of achieving a stable and successful analysis of synaptic transmission modulation when performing field potential or intracellular recordings. This manuscript describes methodological aspects that might be helpful in improving experimental conditions for the maintenance of acute brain slices and for recording field excitatory postsynaptic potentials in a commercially available submersion chamber with an outflow-carbogenation unit. The outflow-carbogenation helps to stabilize the oxygen level in experiments that rely on the recycling of a small buffer reservoir to enhance the cost-efficiency of drug experiments. In addition, the manuscript presents representative experiments that examine the effects of different carbogenation modes and stimulation paradigms on the activity-dependent synaptic plasticity of synaptic transmission.

Introduction

In 1951, the first-reported acute brain slice experiments were conducted1. In 1971, after successful in vitro recordings from the piriform cortex2,3 and the discovery that hippocampal neurons are interconnected transversely along the septotemporal axis of the hippocampus4, one of the first in vitro recordings of hippocampal neuronal activity was achieved5. The similarity of the neurophysiological or neurostructural parameters of neurons under in vivo and in vitro conditions are still the subject of some ....

Access restricted. Please log in or start a trial to view this content.

Protocol

The animals were maintained in accordance with the established standards of animal care and procedures of the Institutes of Brain Science and State Key Laboratory of Medical Neurobiology of Fudan University, Shanghai, China.

1. Solution Preparation

NOTE: See the Table of Materials.

  1. Prepare the slicing buffer (modified Gey's solution): 92 mM NaCl, 2.5 mM KCl, 1.25 mM NaH2PO4, 30 mM NaHCO3, 25 mM glucose, 20 mM HEPES, 3 mM Na+-pyruvate, 10 mM MgSO4, and 0.5 mM CaCl2.
  2. Adjust the pH to 7.6 using 1 M NaOH without carbogenation.
  3. Store the buff....

Access restricted. Please log in or start a trial to view this content.

Results

In the protocol section, we described the preparation of acute hippocampal slices from the ventral and intermediate part of the hippocampal formation (Figure 1) of male C57BL/6 mice and male Wistar rats (5-8 weeks). The position of the hemispheres on the slicer platform helps to keep them stable and removes the need of stabilization with agar or agarose. The perfusion system itself is based on a peristaltic pump operated on high rotation to give the required .......

Access restricted. Please log in or start a trial to view this content.

Discussion

Although interface slice chambers exhibit more robust synaptic responses25,26,27,28, submersion chambers provide additional convenience for patch-clamp recording and fluorescence imaging. Thus, we have described several aspects of field potential recordings in acute hippocampal slices using a commercial submersion slice chamber that can easily be extended to the imaging of fluorescence probes i.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Acknowledgements

W.W. conducted, analyzed, and designed the experiments and wrote the manuscript. D.X. and C.P. assisted in figure preparation and conducted the experiments. This work was supported by NSFC (31320103906) and 111 Project (B16013) to T.B.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
Reagents required
NaClSinopharm Chemical Reagent, China10019318
KClSinopharm Chemical Reagent, China10016318
KH2PO4Sinopharm Chemical Reagent, China10017618
MgCl2·6H2OSinopharm Chemical Reagent, China10012818
CaCl2Sinopharm Chemical Reagent, China10005861
NaHCO3Sinopharm Chemical Reagent, China10018960
GlucoseSinopharm Chemical Reagent, China10010518
NaH2PO4Sinopharm Chemical Reagent, China20040718
HEPESSigmaH3375
Sodium pyruvateSigmaA4043
MgSO4Sinopharm Chemical Reagent, China20025118
NaOHSinopharm Chemical Reagent, China10019718
Tools and materials for dissection
DecapitatorsHarvard apparatus55-0012for rat decapitation
Bandage ScissorsSCHREIBER12-4227for mouse decapitation
double-edge bladeFlying Eagle, China74-C
IRIS ScissorsRWD, ChinaS12003-09
Bone RongeursRWD, ChinaS22002-14
SpoonHammacher HSN 152-13
dental cement spatulaHammacher HSN 016-15
dental double end excavatorBlacksmith Surgical, USABS-415-017
Vibrating MicrotomeLeica, GermanyVT1200S
surgical blade RWD, ChinaS31023-02
surgical holderRWD, ChinaS32007-14
Electrophysiology equipment and materials
Vertical Pipette PullerNarishige, JapanPC-10
Vibration isolation tableMeirits, JapanADZ-A0806
submerged type recording chamberWarner InstrumentsRC-26GLP
4 Axis MicromanipulatorSutter, USAMP-285, MP-225
Platinum WireWorld Precision InstrumentsPTP406
AmplifierMolecular Devices, USAMulticlamp 700B
Data Acquisition SystemMolecular Devices, USADigidata 1440A
Anaysis softwareMolecular Devices, USAClampex 10.2
Fluorescence MicroscopeNikon, JapanFN1
LED light sourceLumen Dynamics Group, CanadaX-cite 120LED
micropipettesHarvard apparatusGC150TFextracelluar recording
borosilicate micropipettesSutter, USABF150-86patch clamp
tungsten electrodeA-M Systems, USA575500
peristaltic pumpLonger, ChinaBT00-300T
tubes for peristaltic pumpISMATEC, Wertheim, GermanySC03091x inflow, ID: 1.02 mm
tubes for peristaltic pumpISMATEC, Wertheim, GermanySC03192x tubes for outflow, ID: 2.79 mm
CCD cameraPCO, Germanypco.edge sCMOS
lens cleaning paperKodak
50 mL conical centrifuge tubeThermo scientific339652
PrechamberWarner InstrumentsBSC-PC
Inline heaterWarner InstrumentsSF-28
Temperature ControllerWarner InstrumentsTC-324B

References

  1. McIlwain, H. Metabolic response in vitro to electrical stimulation of sections of mammalian brain. Biochem J. 48 (4), (1951).
  2. McIlwain, H., Richards, C. D., Somerville, A. R. Responses in vitro from the piriform cortex of the rat....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Hippocampal Slice PreparationField Potential RecordingSynaptic Plasticity AnalysisCarbogenation SystemSubmersion ChamberACSF RecyclingElectrophysiology TechniquesStimulation ProtocolsLong-Term RecordingsNeuroplasticity Research