In Vivo Electrophysiological Measurement of the Rat Ulnar Nerve with Axonal Excitability Testing

9.4K views

⸱

DOI:

10.3791/56102

⸱

February 6th, 2018

 ,  ,  ,  ,  , 

In This Article

Summary

Axonal excitability techniques provide a powerful tool to examine pathophysiology and biophysical changes that precede irreversible degenerative events. This manuscript demonstrates the use of these techniques on the ulnar nerve of anesthetized rats.

Abstract

Electrophysiology enables the objective assessment of peripheral nerve function in vivo. Traditional nerve conduction measures such as amplitude and latency detect chronic axon loss and demyelination, respectively. Axonal excitability techniques "by threshold tracking" expand upon these measures by providing information regarding the activity of ion channels, pumps and exchangers that relate to acute function and may precede degenerative events. As such, the use of axonal excitability in animal models of neurological disorders may provide a useful in vivo measure to assess novel therapeutic interventions. Here we describe an experimental setup for multiple measures of motor axonal excitability techniques in the rat ulnar nerve.

The animals are anesthetized with isoflurane and carefully monitored to ensure constant and adequate depth of anesthesia. Body temperature, respiration rate, heart rate and saturation of oxygen in the blood are continuously monitored. Axonal excitability studies are performed using percutaneous stimulation of the ulnar nerve and recording from the hypothenar muscles of the forelimb paw. With correct electrode placement, a clear compound muscle action potential that increases in amplitude with increasing stimulus intensity is recorded. An automated program is then utilized to deliver a series of electrical pulses which generate 5 specific excitability measures in the following sequence: stimulus response behavior, strength duration time constant, threshold electrotonus, current-threshold relationship and the recovery cycle.

Data presented here indicate that these measures are repeatable and show similarity between left and right ulnar nerves when assessed on the same day. A limitation of these techniques in this setting is the effect of dose and time under anesthesia. Careful monitoring and recording of these variables should be undertaken for consideration at the time of analysis.

Introduction

The use of electrophysiological techniques is an essential tool for the in vivo investigation of peripheral nerve function in neurological disorders. Conventional nerve conduction methods utilize supramaximal stimuli to record motor action potential amplitude and latency. These techniques therefore provide useful information on the number of conducting fibers and on the conduction velocity of the fastest fibers. A valuable complementary tool is that of axonal excitability testing. This technique uses sophisticated electrophysiological stimulation patterns to indirectly assess the biophysical properties of peripheral nerves, such as the activity of ion channel....

Access restricted. Please log in or start a trial to view this content.

Protocol

All experimental procedures described here complied with the Animal Care and Ethics Committee of UNSW Sydney and were performed in accordance with the National Health and Medical Research Council (NHMRC) of Australia regulations for animal experimentation.

1. Experimental Set Up

NOTE: 12 week old, female Long-Evans rats were used in this procedure.

  1. Anesthetize the rat in an induction chamber using 4% isoflurane and 1 L per min O2 flow rate. Confirm sufficient anesthesia by testing for the righting reflex and ensure its absence before removing the animal from the induction chamber. Note that....

Access restricted. Please log in or start a trial to view this content.

Results

Electrophysiological measures of the rat ulnar nerve were obtained with the present protocol. Figure 3 demonstrates a representative recording from the left ulnar nerve of a 12 week-old female Long Evans rat. Compound muscle action potential relates to the number of conducting fibers that are simultaneously activated. The supramaximal peak response (mV) (Figure 3A) demonstrates the peak response achieved when incrementally increa.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The described procedure demonstrates a simple and reliable, minimally-invasive technique that allows assessment of the biophysical properties and membrane potential of the axon in a short period of time. Compared with other more invasive techniques, which require the exposure of the nerve, the present method of axonal excitability testing induces minimal tissue damage thus enabling in vivo assessment that preserves the physiological conditions of the nerve of interest and allows for repeated measurements.

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

The project was supported by Lundbeck Foundation, the Novo Nordisk Foundation, the Danish Medical Research Council, the Ludvig and Sara Elsass Foundation, the Foundation for Research in Neurology and Jytte and Kaj Dahlboms Foundation. R.A is supported by an Early Career Post-Doctoral Fellowship of the National Health and Medical Research Council of Australia (#1091006)

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
QTracS ProgramDigitimer Ltd.Axonal excitability program
AM-Systems 2200, Analog Stimulus Isolator, 2200V/50HzSDR Scientific850005Stimulator
High Performance AC Amplifier Model LP511Grass TechnologiesAmplifier
Humbug 50/60Hz Noise eliminatorQuest Scientific Instruments726310Noise eliminator
Low Impedance Platinum Monopolar Subdermal Needle ElectrodesGrass TechnologiesF-E2-24Recording electrodes, 10 mm length, 30 gauge
Low Impedance Platinum Electroencephalography Needle ElectrodesCephalon9013L0702Stimulating electrodes, 10 mm length, 30 gauge
Multifunction I/O Device Model USB-6341National InstrumentsMultifunction input/output device
Iron Base Plate IPNarishige Scientific Instrument LaboratoryUsed for holding stimulating needle electrode in place
Rotating X-block X-4Narishige Scientific Instrument LaboratoryUsed for holding stimulating needle electrode in place
Magnetic Stand GJ-8Narishige Scientific Instrument LaboratoryUsed for holding stimulating needle electrode in place
Micromanipulator M-3333Narishige Scientific Instrument LaboratoryUsed for holding stimulating needle electrode in place

References

  1. Krishnan, A. V., Lin, C. S. -Y., Park, S. B., Kiernan, M. C. Axonal ion channels from bench to bedside: a translational neuroscience perspective. Prog neurobiol. 89 (3), 288-313 (2009).
  2. Lin, C. S. -Y., Krishnan, A. V., Park, S. B., Kiernan, M. C.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Threshold TrackingStimulus Response CurveCompound Muscle Action PotentialRecovery CycleCurrent Threshold RelationshipThreshold ElectrotonsIn Vivo Measurement