The described protocol aims at retrieving cells from a functionalized wire (referred to as Device) for ex vivo single-cell genomic analysis. We tested three EpCAM-positive cell lines (HT-29, LNCaP, and VCaP), but in principle, this method can be applied to any cell line expressing EpCAM. EpCAM-positive target cells can be presented to the Device as pure cell suspension (see 2.1.) or mixed into a surplus of background cells (e.g. peripheral blood, see 2.2.). Whereas especially the latter might be used to test isolation capacities under rare cell conditions, fine tuning of the number of cells attached to the wire can be done using the described low-volume approach (see 2.3.). As differences between cell lines are to be expected, suitable cell densities for charging the wire, rotation speed as well as incubation time need to be tested empirically by evaluating the number of attached cells using an immunofluorescence microscope.
For genomic downstream applications at the single-cell level WGA, is required. The WGA method of choice may differ between labs and, in principle, our method is open to all methods than can handle samples obtained from micromanipulation or laser microdissection. In this protocol, we use a method based on enzymatically fragmented DNA due to a better performance as compared to a heat-fragmentation based WGA7. Optional, single cells can be forwarded to isothermal WGA allowing subsequent DNA profiling20,21.
The described protocol aims at recovering intact cells after being attached to a new generation of functionalized wires for genomic single-cell analysis. The first generation of functionalized wires, which also represent the only CE-approved in vivo enrichment devices on the market so far, were used for enumerating CTCs in metastasized cancer patients. Previous publications and our own data suggest the in vivo isolation technique to be more sensitive compared to the current gold standard technology2. Thus, equipping this in vivo isolation technique with a recovery feature as realized in the Device allows combining high CTC recovery with characterization at the single-cell level.
However, the Device is not cleared for the use in patients, thus, clinical data are not available. Ex vivo applications (i.e. isolating CTCs from peripheral blood after sampling) are not recommended as the technology is adapted to the settings present in the cubital vain, e.g. low diameter of the vain (increasing the probability of direct contact between CTCs and catching antibodies) and long retention time (30 min, allowing 2-3 L of blood to pass the wire). However, as outlined in section 2.2. target cells can also be isolated from mixed samples7.
A current limitation of the method is the inefficient recovery of unfixed cells after detachment from the wires. This, however, might be improved by a cell fixation step prior to the detachment treatment.
In summary, this protocol is a first step towards the combined use of an in vivo isolation technique with cell recovery for genetically characterizing single cells. Further efforts need to address the optimization of the cell recovery and clearance for its application in patients1,2. However, personalized medicine for treatment monitoring and therapy decisions is beyond enumeration of CTCs. Thus, this method is a first step towards genomic CTC characterization at the single cell level.
Applications towards single-cell transcriptome analysis seem feasible as intact cells are harvested. However, it remains to be assessed whether the recovering procedure has an impact on RNA integrity (e.g. forwarding recovered single cells to direct lysis followed by RT-qPCR22). If successful, characterization of single cells (e.g. CTCs) can be shifted to the transcriptome level , allowing more detailed analyses. In this regard, RNA-seq using Smart-seq2 provides a valuable tool for RNA downstream analysis of single cells as the preamplified cDNA (obtained during RNA-seq library preparation) can be subjected to quantitative PCR. This will allow a combined target and screening-based analysis of single recovered cells22,23.
The current functionalized wires are based on anti-EpCAM antibodies which is a widely used epithelial marker for positive selection of CTCs24. As several CTCs might downregulate epithelial markers such as cytokeratins or EpCAM25, adding antibodies such as HER2/new would increase the chance of CTC isolation. Several antibody based enrichment strategies have been developed and reviewed by Ferreira et al. in 201626. A mixture of antibodies immobilized on a wire could be a future improvement of the technology leading to the isolation of a higher number and additional subtypes of CTCs.
It is mandatory for all steps involving wire handling to keep the functional part of the wire submerged in solution in order to maintain its functionality. We recommend to place the wire in 1x PBS during evaluation (microscope; e.g. steps 3.1. - 3.3.) and storage. In order to avoid inappropriate staining, we recommend using freshly prepared staining solution in steps 1.2.1. and 1.2.2. Weakly stained cells hamper cell counting on the wire and may lead to the underestimation of the attached cells.
It is necessary to avoid plugging the Pasteur pipette with the rubber cap when inserting the wire in the Pasteur pipette for subsequent loading of the cell suspension (step 2.3.4.). The rubber cap is used to hold the wire in place so that the functional part is situated inside the tip of the Pasteur pipette. If the cap is attached too firmly to the rear of the Pasteur pipette, loading of the cell suspension is not possible. In this case, ease the cap such that the air which is displaced by the loaded cell suspension can leave the pipette.
Bending the wire is crucial for its orientation during the cell counting in steps 3.2. and 3.3. Mount the wires using the adhesive tape such that the non-functional end of the wire comes to lie to one side. After scanning of the entire length of the functional part, the wire is rolled 180° so the other half of the functional wire can be scanned. This step is important for initial experiments to assess the number of cells on the wire. Once the number of cells for a certain cell line and procedure is evaluated, the procedure can be repeated without cell counting (e.g. only checking for presence of cells or omitting this step). Careful pipetting is crucial to avoid cell loss when reducing the volume of the supernatant in step 4.8. Make sure pipetting is done smoothly without causing turbulences to the pellet.