The ongoing cancer immunotherapy revolution is opening novel and promising therapeutic options for cancer patients13. Advances in the field of immuno-oncology will require increased knowledge of the inflammatory tumor microenvironment, not only to understand the biology of the immunological mechanisms involved in carcinogenesis but also to find predictive biomarkers for new immunotherapy-based treatments1,2. Due to the complex biology of cancer immunology, interrogation of tumor tissue samples is usually required to develop a growing list of immune markers, which interact with each other and are frequently coexpressed by diverse cell populations in the tissue1,2,5. Clinical trials typically employ small biopsies, such as core needle or endoscopic biopsies, which are collected at different points of therapy to evaluate and monitor patient response. Such biopsies provide limited amounts of tissue, which in turn limits the number of tissue sections that can be employed for cancer immunoprofiling. This limitation is particularly onerous when traditional techniques, such as standard monoplex IHC, are used. There is, therefore, a clear need for new methods for cancer immunoprofiling that make use of multiplex techniques with the capacity to simultaneously evaluate the coexpression of different biomarkers and to make more efficient use of valuable tissue specimens.
In the multiplex staining and multispectral imaging methods described in detail here, an mIF panel is used for immuno-oncology studies on FFPE tissues such as biopsies from a clinical trial. This method has been previously described, validated, and successfully applied to cancer immunoprofiling8,9,10,11,12,14,15. Previously published protocols have described similar mIF staining methods with TSA-based systems, such as the seven-color kit, which is time-consuming and requires approximately 4 days of work by a dedicated laboratory scientist12,15. In response to these shortcomings, this protocol has been optimized by using a commercially available automated stainer, dramatically shortening the staining time to 14 h and eliminating the variability introduced by manual operators. Imaging is conducted on a multispectral scanner capable of separating the spectra of the seven or more fluorescent signals in the multiplex slides, including autofluorescence, which can be efficiently removed without degrading the signal quality. This protocol can be replicated, modified, and performed by any laboratory user with access to the instruments and reagents detailed in the Table of Materials.
Critical steps in this protocol are sections 7, 10, 11, 12. Section 7 pertains to the preparation of reagents. A careful preparation of the reagents for multiplex staining is essential, requiring the focused attention of a laboratory scientist or technician to avoid operator-dependent variation. For instance, one of the major issues with the multiplex method is staining variability, which can be reduced by the careful preparation of the dilutions of the reagents, specifically the TSA dyes. Sections 10 and 11 are related to image acquisition. An important risk is the overexposure or oversaturation of the images, which may lead to spectral bleed, an artifact in which the signal from another channel interferes with the channel being imaged (see Supplemental Materials). Carefully regulating the exposure times can help to prevent oversaturation and spectral bleed. Spectral unmixing is conducted in section 12. This relies on the preparation of the spectral library (described in the Multiplex IHC Assay Development Guide, available online). In this step, the inForm software is "trained" to specifically recognize the colors for each TSA dye. The spectral library is created by using sections from a control tissue, such as human tonsil, stained with a uniformly expressed marker, such as CD20, coupled with each individual TSA dye on individual slides. In addition, autofluorescence slides (also described in the Multiplex IHC Assay Development Guide) are needed to train the inForm software to recognize and subtract tissue autofluorescence. Autofluorescence control slides should be prepared by using samples from the same tissues being studied (such as lung cancer, etc.), treated in the same way as the mIF slides, and incubated with primary and secondary antibodies but without the TSA dye. Only a single autofluorescence spectral profile can be selected, so care must be taken to select a representation of the observable autofluorescence which may come from collagen, fibrosis, red blood cells, endogenous pigments, and other sources. Creating a new spectral library at the beginning of each new project and using an autofluorescence spectrum which is representative of the tissue study specimens, as well as running the same tissue blocks as the positive control for each batch within the same project, are valuable methodological steps that will help to improve the consistency of the spectral unmixing across different samples within the same project.
The multiplex method described in this protocol offers several troubleshooting tools, including a signal-to-noise evaluator (counts tool), drop controls (Supplemental Materials), and a pathology view for quality control of the staining. The counts tool helps to evaluate the intensity of the staining and the level of background. If the intensity and/or background levels are high, the first approach is to reduce the dilution of the TSA dye. If the problem persists, the chromogenic IHC slides used for the optimization of that particular marker should be reviewed with a pathologist, looking for the presence of background. The pathology view is generated by the inForm software, using a diaminobenzidine-like pseudocolor representation of the fluorescence from the TSA-linked fluor, as well as a faux hematoxylin representation generated from all fluorescent signals, including DAPI. Images from the pathology view help with the visual evaluation of the staining patterns by a pathologist for improved staining. These tools should always be employed during the optimization of a new panel and as quality control steps during the staining workflow.
The mIF method requires the use of primary antibodies that have been properly validated and optimized for standard chromogenic IHC on formalin-fixed tissues. For instance, one of the major advantages of the mIF TSA method is its compatibility with the use of primary antibodies that have been validated and optimized in the anatomic pathology laboratory for clinical use12. This advantage means that the multiplex panels can be customized by the laboratory user to answer specific cancer immunology questions without the need for preconjugated antibodies, providing rapid and dynamic panel development. In this regard, the actual workflow for the optimization of a new panel begins with the validation and optimization of the antibodies with standard chromogenic IHC, looking for the best dilution and staining conditions that will provide clean and consistent staining. The next step, using the same dilutions optimized for IHC, is to transfer the staining by using TSA fluors instead of diaminobenzidine and to compare the results of monoplex immunofluorescent TSA with the chromogenic IHC as reference. Finally, the antibodies can be combined in mIF staining, always using the chromogenic IHC staining pattern as a control reference to adjust the mIF TSA staining parameters, mainly the TSA dye dilutions and the staining sequence. During this process, collaboration with a pathologist is instrumental to evaluate the quality of the staining.
Limitations of this technique include the time and effort required for the optimization and validation of new panels and the immunophenotyping analysis of mIF panels. The main concern, however, is the proper validation of mIF methods. The lack of proper validation of these techniques carries the risk of generating invalid results, which may add confusing data to the literature, thereby hindering attempts to gain a better understanding of the biology of cancer immunology16. It is, therefore, incumbent on the investigator to make every effort to properly validate multiplex methods, including ensuring close participation and evaluation by pathologists with training and experience in validation and evaluation of tissue histopathology and IHC-based techniques17,18,19,20. The protocol presented here includes some of the tools that can help with the validation of a new multiplex panel, including the pathology evaluation of H&E slides before staining and analysis, the use of chromogenic IHC as a reference to optimize the mIF TSA staining, the drop control method for quality control of a new multiplex panel, and the use of isotype, autofluorescence, and drop controls. Despite the technical complexity of mIF methods, technologies such as multispectral imaging with spectral unmixing, as well as other novel multiplex platforms, are opening a new era for the analysis of tissue specimens from patients and the generation of new forms of data that is not possible with standard IHC alone. Therefore, the development and application of mIF techniques will continue to grow, becoming powerful tools for the cancer immunoprofiling of biopsies for clinical trials and helping to identify new multiparametric predictive biomarkers for immunotherapy, benefiting, above all, the cancer patient.