Following the protocol described in section 1, moribund red hybrid tilapia displaying clinical signs of TiLV infection (Figure 1A) were euthanized by bathing in a high concentration of clove oil, which acts as an anesthetic. Reported clinical symptoms are variable but the common symptoms appear to be lethargy, skin erosion and discoloration, exophthalmia, detached scales, open wounds/Lesion and abnormal behaviour15,16,33,35,36, some of these can be clearly seen in Figure 1A. The abdominal wall was removed to collect internal organs such as the liver, spleen or head kidney (Figure 1B). Mucus samples were also collected at this stage by gently scraping the skin from the anterior to posterior of the fish using a cover glass or surgical blade37.

Figure 1. Tilapia dissection and sample collection.A. TiLV-infected red hybrid tilapia with skin leisons, redness around the mouth and operculum, skin erosion and corneal opacity. B. Sectioned red hybrid tilapia to allow for tissue collection from the liver (at the point of blue arrow), spleen or head kidney organs. Please click here to view a larger version of this figure.
Thereafter, the protocol detailed in section 2 for Guanidium Thiocyanate-Phenol-Chloroform extraction of total RNA was followed and RNA quantification as outlined in section 3 was performed to assess sample purity by calculation of the purity ratios and examination of spectral profiles (Figure 2). Figure 2A shows a representative result from a successful total RNA extraction procedure, while Figure 2B represents a poor RNA preparation. Nucleic acids have absorbance maxima at 260 while proteins have theirs at 280 nm. The ratio of the measurements at 260 nm and 280 nm indicate the purity of each sample and ratios of 1.9 to 2.1 indicate pure RNA as is the case for the sample in Figure 2A. Lower A260/280 ratios observed in Figure 2B indicate possible protein or phenol contamination leftover from the RNA extraction procedure. Absorbance at 230 nm can be the result of sample contamination and the A260/230 nm ratio is also calculated for this reason. This ratio should be in the range of 2.0-2.2 for pure RNA preparations as illustrated by a value of 2.03 for the sample in Figure 2A, while Figure 2B has a low A260/230 ratio of 1.07 and the spectral profile shows a shift in the trough at 230 nm towards 240 nm which is indicative of residual guanidine or phenol in the sample. For the sample shown in Figure 2B, re-precipitating the RNA to remove the contamination may improve the purity of the sample.

Figure 2. Spectrophotometric quantification of total RNA extracted from diseased tilapia tissues. A. purity ratios and spectral profiles from a successful RNA preparation. B. As A, except representative of a poor RNA extraction procedure. Please click here to view a larger version of this figure.
To detect TiLV by RT-PCR, pure samples such as the one represented in Figure 2A were reverse transcribed (protocol 4) into cDNA and used as a template for the PCR assay detailed in section 5 and representative results are shown in Figure 3A. Primers shown in bold in Table 1 were used to amplify a 491 bp fragment of TiLV genomic segment 314. The PCR products were separated by gel electrophoresis and stained with EtBr for visualization. Figure 3A shows the results of a two-step RT-PCR using 4 cDNA samples (S1-S4), derived from the liver of diseased tilapia isolated in Thailand, and in each sample, a clean single band of approximately 500 bp can be observed and thus, samples 1-4 are TiLV positive. The same PCR product was obtained from the positive control sample, comprising cDNA of TiLV segment 3 cloned into a plasmid32 while the no template control (NTC) did not yield PCR products. The assay in Figure 3B was performed using the same primers as in Figure 3A but in a different laboratory, using a one-step RT-PCR approach and with 5 RNA samples derived from the head kidney tissues of tilapia originating in Egyptian aquaculture15. It was determined using this detection assay that samples 1, 3 and 5 are TiLV positive while samples 2 and 4 are TiLV negative since no PCR product was found at the correct size. The negative controls, including two minus reverse transcriptase controls and two NTCs did not generate any PCR products. A one-step RT-PCR assay was also performed targeting tilapia ActinB gene. The amplicon size of 217 bp was generated in every sample (S1-S5) as expected38. This assay served as a control for the integrity of the RNA samples as well as allowing for a semi-quantitative examination of the TiLV positive samples. Given that the generated Tilapia ActB product is relatively equal, then differences in the amount of TiLV specific PCR product generated can be interpreted as a true reflection of the amount of TiLV in a given tissue sample.

Figure 3. TiLV RT-PCR. A. cDNA samples produced from liver tissues of diseased tilapia, collected from Thailand were screen for TiLV infection using specific primers for segment 3 (shown in bold in Table 1) of TiLV using a 2-step RT-PCR assay. M = marker shown in base-pairs; S1-S4 = samples 1-4; C1 = positive control using pTiLV as a PCR template; and C2 = no template control (NTC). B. One-step RT-PCR using the same primers as in A and samples from head kidney tissues of diseased tilapia collected from Egypt15. M = marker shown in base-pairs; S1 -S5 = samples 1-5. Controls C1-C2 are minus reverse transcriptase controls and C3-C4 are NTCs. Bottom panel is a one-step RT-PCR using primers directed against tilapia ActinB38 (see text for details) producing a PCR product of 217 base-pairs. Please click here to view a larger version of this figure.
Unlike the endpoint PCRs represented in Figure 3, qPCR assays which are explained in protocol 6, measure the amount of PCR product after each PCR cycle. The amplification of target DNA is detected using fluorescent molecules that interact with DNA generated from each round of reaction. Here, SYBR Green I dye was utilized, which intercalates with double-stranded DNA. The fluorescent signal is followed during the reaction and its intensity relates to the amount of product formed 39,40,41,42,43. TiLV qPCR assays were carried out as described in protocol 6 in different laboratories using different SYBR Green reagents, qPCR machines and samples from different countries. The resulting amplification curves are shown in Figure 4A and 4B. It can be observed that for each assay, the course of the experiment has four phases: the linear ground phase, early exponential phase, late exponential phase and the plateau phase. The linear ground phase occurs during the early cycles where DNA duplication cannot yet be identified due to DNA quantities producing insufficient signal/background ratio. Baseline fluorescence is calculated during this phase. Thereafter, target DNA starts to double in concentration with each cycle inducing the signal to become detectable above background and increase exponentially. The amplification efficiency (E) of a well-optimized qPCR assay is very high (near 100%) in the beginning of the reaction and remains stable during this early exponential phase of the amplification and it is at this point that quantification is performed, when reaction efficiency is still steady. In later cycles the signal starts to plateau, and the intensity of the fluorescence is no longer correlated to the starting template copy number because the reaction components are exhausted44. Saturation may also occur due to competition from re-annealing reactions, the changing concentration ratios of the components, or the amount of enzyme units to DNA substrate molecules. Possibly, such parameters account for the differences between the amplification curves for the assays shown in Figure 4A and 4B. The included controls did not generate these characteristic amplification curves.

Figure 4. Amplification plots to show the accumulation of product over the duration of the real-time PCR assay. A. Amplification curves of TiLV-positive samples derived from Thailand, NTCs, and positive plasmid control using a SYBR-Green I 2-step qPCR assay. The chart was generated by plotting relative fluorescence (RFU) vs. cycle number. B. Amplification curves of TiLV positive samples derived from Egypt, as in Figure 3B and a NTC. The amplification curve is the fluorescence of the reporter signal normalized to the fluorescence of the passive ROX dye included in the assay (Rn) versus cycle number. Please click here to view a larger version of this figure.
At the end of the qPCR thermocycling on the different machines in each laboratory, the data was acquired and analyzed. Figure 5A and 5B show representative melting curves from the assays performed in each laboratory. Each qPCR machine was programmed to perform a melting curve analysis at the end. This was achieved by incrementally increasing the temperature and monitoring the fluorescence as a function of the temperature. When the temperature is high enough to denature dsDNA, a large drop in fluorescence is recorded because the fluorophore molecule is released. The software of each qPCR instrument calculated the annealing temperature (Tm) from the melting curve data by plotting the negative first derivative vs temperature (Figure 5). It can be seen that in Figure 5A and 5B that the products formed in the different sample sets have uniform melting transition at the expected temperature of approximately 80 °C for the assay. No other peaks at lower temperatures were observed. Due to their small size, the Tm of primer-dimers is typically lower than that of the target DNA sequence. Therefore, this difference between the Tm's makes it easy to identify potential primer-dimers or other non-specific amplification products. The controls did not generate melt curves like TiLV positive samples and standards and can be seen as an almost horizontal line at the bottom of the charts in Figure 5A and 5B.

Figure 5. Melt curve analysis to ensure assay specificity and different PCR products can be differentiated by their melting features. A. Melt curve analysis of TiLV-positive samples originating from Thailand, negative control, and positive plasmid control. B. Melt curve analysis of TiLV positive samples derived from Egypt, pTiLV standards and a NTC. The charts in A and B both show the change in fluorescence divided by the change in temperature plotted against temperature to produce a clear picture of the melting dynamics. Please click here to view a larger version of this figure.
Most qPCR machines come with a software facilitating further evaluation the qPCR run and will quantify the samples by generating a standard curve by automatically plotting the cycle threshold (Ct) against the logarithm of the pTiLV standards' template copy number as shown in Figure 6A and 6B for the two independent laboratories. Briefly, the Ct is the unit used for evaluating qPCR results. The Ct value denotes the number of cycles required to reach a set threshold fluorescence signal level. The greater the amount of starting template, the fewer cycles it takes to attain a detectable fluorescence level. Indeed, samples with a high load of TiLV will have lower Ct values than samples with a low load of TiLV such as in fish with a sub-clinical infection. To determine Ct values, background fluorescence levels are first deducted from raw data. Next, the software associated with the qPCR device will automatically select a fluorescence threshold by searching the data curves for each sample and incorporating a Ct representing where the sample crossed the threshold.This is done separately for each assay and each threshold should be carefully evaluated, ensuring that the threshold has been set in the logarithmic part of the amplification curves and at a place where all curves are parallel. Thus, the specific Ct acquired is a relative value and it is relative to the starting template copy number45, but it is also specific for the qPCR machine and reagents used, the efficiency of the PCR amplification and the sensitivity of detection. These parameters contribute to the differences observed using the same assay in Figure 6.
From the standard curves in Figure 6, regression analyses, including calculation of standard curve slopes (m) and intercepts, amplification efficiencies (100 x (101/m -1))46 and linearity of the reaction were performed. Standard curve analyses were also used to confirm sensitivity (limit of detection), repeatability and reproducibility of the assay. Theoretically, the amount of DNA is doubled with every PCR cycle, meaning that the efficiency (E) is equal to 100%. However, in practice such an ideal efficiency is seldom reached due to sub-optimal PCR conditions such as, DNA polymerase inhibition, contaminants, too much cDNA and pipetting errors47. Typically, amplification E range from 90-110% for good assays, in Figure 6A an efficiency of 94.5% was calculated using 8 serially diluted pTiLV samples, while, the assay efficiency in the assay shown in Figure 6B using 7 serially diluted pTiLV samples was 101.2%. An efficiency of over 100% is usually due to the presence of PCR inhibitors in the assay. Linear regression analysis of the standard plot also allows for the calculation of the number of TiLV copies in each sample41,42,45, as can be observed for the three TiLV samples shown in red in Figure 6B which is in line with the results for samples S1, S3 and S5 shown in Figure 3B.

Figure 6. RT-qPCR standard curves. Real-time PCR of 10-fold serial dilutions of pTiLV, the standard used in both laboratories. A. 8 serially diluted pTiLV samples were tested, all of known concentration and correlated to the number of TiLV copies/ reaction. The standard curve was generated by plotting log copy number vs. cycle threshold (Ct). The slope = -3.462, R2 = 0.9992 and the efficiency is 94.47%. B. As in A, except 7 serially diluted pTiLV samples (green) were tested and the chart displays the threshold cycle on the y-axis and the copy number of TiLV (Quantity) on the x-axis. The y-intercept = 32.327, slope = -3.292, R2 = 0.98 and the efficiency is 101.2%. For both standards curves in A and B, the slope, y-intercept and correlation coefficient values (R2) are utilized to understand the performance of the assay. Importantly, R2 value should be close to 1 since it is a measure of the linearity of the standard curve. The slope is used to measure PCR efficiency wherein 100% efficiency corresponds to a slope of -3.32, see main text for the equation and further details. A good qPCR reaction generally has an efficiency between 90-110% correlating to a slope of between -3.58 and -3.10. The standard curve is used for absolute quantification of unknown TiLV positive samples and determines the exact number of TiLV copies / reaction, as is the case for the three TiLV positive samples colored red in B.