Here, a procedure for repeated 2P imaging of the dorsal CA1 in live mice is described. After the surgery, the mouse usually recovers within 2 days. The procedure induces minimal astrogliosis26,43. Hemorrhage and edema which might follow the surgery are usually re-adsorbed within 10 to 14 days. Generally, from 14 days post-implantation onwards the preparation is sufficiently clear to perform intravital imaging. The success of the surgery does not depend on working in a sterile environment. However, it is crucial to maintain a high level of hygiene, to avoid complications due to surgery-associated infections. This is obtained by meticulously cleaning the surgical instruments before and after the surgery and by heat-sterilizing them immediately prior to each usage (step 2.1.1). The optic cannula is kept into a clean, sterilized container and rinsed with sterile saline just before the implantation. Performing common surgical practices of hands disinfection and cleaning of the surgical station is also very important. The preparation remains stable and allows cellular and subcellular resolution imaging for several weeks26,35.
Critical steps, modifications and troubleshooting.
It is important to peel the external capsule until the deepest fibers are exposed. Failure to expose the alveus might result in the inability to focus on the soma of PNs, or in reduced resolution imaging dendritic spines, when using commercial objectives with 3- or 4-mm WD. To this aim, it is useful to ablate the neocortex very slowly using a 0.9 mm diameter needle and then switch to a 0.3-0.5 mm diameter (24-29 gauge) needle for a finer control of suction when removing the most dorsal fibers. Alternatively, fine forceps may be used to remove the remaining cortex after fiber exposure36.
Bleeding during surgery can be problematic, as blood obstructs the view. Waiting for the clot to form and then rinsing with saline to wash away residual blood is recommended. Repeat as necessary.
A snug fit between the cannula and the craniotomy helps increase the stability of the preparation by keeping the cannula in place before application of the cement, especially if the outer rim of the cannula is flush with the skull. Since the sizes of the trephine drill and the cannula are matched, a loose fit can arise because of irregularities on the side of the cannula - which require slightly larger craniotomies to fit (see step 2.3.14) - or from an irregular craniotomy. Any cannula irregularities must be filed off (steps 1.3 and 1.12) and the trephine must be held perpendicular to the skull until the craniotomy is completed (step 2.3.12). Removing the trephine from the skull before the craniotomy is completed may result in irregular craniotomies.
Limitations-Invasiveness and stability of the preparation.
It is difficult to evaluate the effect of cortical ablation as it is arduous to precisely define the areas affected directly and indirectly. In general, the surgery removes part of the parietal cortex and part of the visual and hindlimb sensory cortex21. The ablated cortex does not directly project to the hippocampus and hippocampal tissue is neither touched nor injured. Importantly, it has been shown that implantation of an imaging cannula does not grossly alter hippocampal function and specifically hippocampal-dependent learning21,36,37,38,39. Still, it would be important to quantify to what extent both the cannula and the external part of the implant (head holder plate and dental acrylic cap) are chronic stressors by assessing corticosterone blood levels and adrenal gland weight in comparison to unimplanted mice.
The preparation generally remains stable from weeks to months26. In the long term, skin and bone growth tend to displace the acrylic cap and to increase the instability of the imaging preparation.
Optical limitations.
Conventional 2P microscopy allows imaging up to about 1 mm deep into neocortical tissue40,41. Consistent with this, it is possible to image dendrites and dendritic spines located in the SR (Figure 2D-F) or SLM36. However, imaging through a cannula poses limitations to the effective NA. To achieve the maximum resolution, the diameter and depth of the imaging cannulas should be matched to the imaging NA, as smaller diameters and longer depths will clip light of high NA objectives. For instance, when imaging with a 1.0 NA water immersion objective through a 1.6 mm long cannula, a 3.65 mm inner diameter is needed to keep the full NA. However, using a cannula of this diameter will increase the compression on the hippocampus and might affect the health of the tissue, for this reason, we use a cannula with a smaller diameter. When imaging with a 0.8 NA water immersion objective through a 1.6 mm long cannula, an inner diameter of 2.5 mm would be sufficient to keep the full NA. However, 0.8 NA water immersion objectives have a shorter WD (3 mm in our case), which can prevent from focusing at the SP.
These calculations apply to the center of the field of view at the bottom of the cannula. However, moving the imaging field of view sidewise - closer to the edges of the cannula - or focusing deeper into the tissue - farther from the glass surface of the cannula - further decreases the effective NA at the focal plane and thus reduces resolution. This will lead to non-homogenous resolution across the different volumes of imaged tissue and can be a concern for quantitative imaging at subcellular resolution, especially when using super-resolution techniques such as 2P-STED microscopy42. These issues are less important when imaging at cellular resolution.
Tissue motion.
Motion within the tissue - originating from breathing and heartbeat in anesthetized animals - tends to become more severe with increased distance from the imaging cannula. This is possibly because the imaging cannula applies mechanical pressure to the brain thus counteracting some of the motion in the vicinity of the cannula (similarly to neocortical preparations). Thus, although imaging of dendritic spines is possible in SR and SLM, in our hands, it is most robust dorsal to the SO up to ≈200 µm from the surface of the cannula. To compensate for motion, we use resonant scanners and offline averaging. Several images (4 to 6 repetitions) are acquired per image plane of a z-stack at the maximum available speed (30 frames/s). All the repetitions for each z-plane are then deconvolved (using the commercial software, AutoQuant), registered (using ImageJ) and averaged into a single image26. For imaging of somata, motion is often negligible upon anesthesia35 and two averages are often sufficient to compensate for motion artifacts.
Future applications or directions of the method.
The preparation can be combined with micro-endoscopes26,43. Micro-endoscopes are rigid optic probes which use gradient refractive index (GRIN) microlenses to guide light to and from deep tissue18. The use of micro-endoscopes allows cannulas of smaller diameters or even no cannulas at all. However, commercial micro-endoscopes are less well corrected for optical aberrations and have lower NA than commercial objectives. Current probes reach lateral and axial resolutions of ≈0.6-1 µm, ≈10-12 µm, respectively17,18,44. The use of micro-endoscopes also enables the combination of this preparation with head-mounted integrated widefield microscopes45,46,47.
The method lends itself also to use in non-anesthetized mice, and it has been used to investigate cellular activity using Ca2+ sensors in awake head-fixed mice21,37,48,49. In these cases, due to the fast time scales of the fluorescence changes, it is advisable to implement line registration50. It is also possible to adapt the preparation for imaging of other hippocampal sub-regions such as the dentate gyrus (DG)39,51,52. Combining this preparation with 3P excitation53,54 with 1 MHz frequency pulsed laser tuned to 1400 nm, we were able to image deeper into the hippocampal formation reaching the molecular layer, granule cell layer and the hilus of the DG (Figure 4) without removing the overlaying CA1.
In conclusion, we present a method that provides optical access to the dorsal hippocampus and allows longitudinal and correlative studies of the dynamics of hippocampal structure and activity. This technique extends the possibilities of analysis of hippocampal function under physiological and pathological conditions.