The pulsed eddy current (PEC) sensing technique is perhaps the most versatile member of the family of eddy current (EC) non-destructive evaluation (NDE) techniques and has many applications in detection and quantification of defects, and the geometry of metals and metallic structures1. Thickness quantification of conductive ferromagnetic wall-like structures, having wall thicknesses of no more than a few millimeters to a few tens of millimeters, is a high demand engineering service in the field of structural health monitoring of infrastructure. Critical infrastructure made of ferromagnetic alloys that require this service are commonly available in the energy, water, oil, and gas industries. While PEC sensors can be designed following several architectures, the detector coil-based architecture was determined to be the most effective and commonly used in condition assessment of ferromagnetic materials2,3,4,5. Therefore, it is the detector coil-based PEC sensor architecture that sets the foundation to the problem of thickness quantification of conductive ferromagnetic materials.
The detector coil-based PEC sensor architecture is typically comprised of two concentrically wound, air cored, conductive coils2,3,4,5,6 (typically copper coils). It is quite common to wind these coils to be circular in shape2,3,4,5,6, but occasionally, rectangular shaped coils6 have been used. From the two coils in the sensor, one behaves as an exciter coil while the other acts as the detector coil. In a PEC sensor, the exciter coil is excited by a voltage pulse - something that can be characterized as a Heaviside step function in principle. This pulsed excitation generates a transient magnetic field (called the primary field) around the sensor. When the sensor is placed adjacent to a conductive test piece (e.g., a conductive ferromagnetic wall-like structure), this transient magnetic field induces time varying eddy currents in the test piece. These eddy currents generate a secondary magnetic field (called the secondary field) that opposes the primary field. In response to the resultant effect of the primary and secondary fields, a transient voltage is induced in the detector coil - which becomes the time domain PEC signal of interest for this work.
The PEC sensor detector coil voltage decay rate (denoted as β) has been reported6,7,8 to show the proportionality β
μσd2, when a signal is acquired placing a PEC sensor above a conductive ferromagnetic layer of magnetic permeability μ, electrical conductivity σ, and thickness d. Although this decay rate signal feature has considerable immunity to parameters such as sensor size, sensor shape, and lift-off6,7,8, which makes the decay rate highly desirable for challenging NDE scenarios such as in situ pipe condition assessment9,10,11, this feature must be calibrated (i.e., μ, σ of the material being inspected be estimated) to enable thickness (i.e., d) quantification. To enable conventional methods of decay rate-based thickness quantification6,8, this calibration must be done by extracting calibration samples6,8 or by involving eddy current-based material property characterization methods12,13. Alternatively, the complexity of calibration can be avoided by representing thickness in the form of relative thickness. Suppose an NDE exercise is carried out and β values are extracted from signals, then, the β value qualitatively representative of the maximum thickness point in the test piece is considered as a reference (i.e., βref
μσdmax2); then, the thickness of any other location can be represented as a percentage of the maximum thickness in the form
, presenting a relative thickness as the output, which is still useful qualitative information as an NDE output that also carries the simplicity of not having to calibrate for μ, σ. The protocol presented herein describes the steps to be followed to accomplish this.
Since the decay rate β shows generality to the detector coil-based PEC sensor architecture while showing immunity to parameters of the sensor design as well as lift-off6,7,8,14, practitioners may use any detector coil-based PEC sensing system of their choice on a suitable conductive ferromagnetic material to perform relative thickness quantification following the protocol here. A PEC sensor design example for a conductive ferromagnetic material is available for interested readers15. The signals and results presented in this work were acquired using the PEC system developed by University of Technology Sydney6,8. The conductive ferromagnetic material used for representative results acquired by the PEC system is grey cast iron extracted from a pipe test-bed9,10,11 in Sydney Australia.
It should be noted that the methods, results, and discussions presented in this publication explicitly focus on the use of the detector coil-based PEC sensor architecture's time domain signal's decay rate for thickness quantification of conductive ferromagnetic materials. The publication does not include a broader discussion on general conventions of PEC sensing principles and sensor configurations. Other published work16,17,18 can be useful for readers to gain more insight about PEC sensor configurations other than the detector coil-based sensor architecture.