A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

9.3K views

⸱

DOI:

10.3791/60477

⸱

April 24th, 2020

 ,  ,  ,  ,  ,  ,  ,  ,  ,  ,  ,  ,  ,  ,  , 

In This Article

Summary

This method estimates the absorbed dose of different structures for peptide-receptor-radionuclide-therapy (PRRT) with the possibility of avoiding organ overlap on 2D-projections. Serial whole-body planar images permit estimation of mean absorbed doses along the whole body, while the hybrid approach, combining planar images and 3D-SPECT/CT image, overcomes the limitations of structure overlapping.

Abstract

Peptide-receptor-radionuclide-therapy (PPRT) is a targeted therapy that combines a short-range energy radionuclide with a substrate with high specificity for cancer cell receptors. After injection, the radiotracer is distributed throughout the entire body, with a higher uptake in tissues where targeted receptors are overexpressed. The use of beta/gamma radionuclide emitters enables therapy imaging (beta-emission) and post-therapy imaging (gamma-emission) to be performed at the same time. Post-treatment sequential images permit absorbed dose calculation based on local uptake and wash-in/wash-out kinetics. We implemented a hybrid method that combines information derived from both 2D and 3D images. Serial whole-body images and blood samples are acquired to estimate the absorbed dose to different organs at risk and to lesions disseminated throughout the body. A single 3D-SPECT/CT image, limited to the abdominal region, overcomes projection overlap on planar images of different structures such as the intestines and kidneys. The hybrid 2D+3D-SPECT/CT method combines the effective half-life information derived from 2D planar images with the local uptake distribution derived from 3D images. We implemented this methodology to estimate the absorbed dose for patients undergoing PRRT with 177Lu-PSMA-617. The methodology could, however, be implemented with other beta-gamma radiotracers. To date, 10 patients have been enrolled into the dosimetry study with 177Lu-PSMA-617 combined with drug protectors for kidneys and salivary glands (mannitol and glutamate tablets, respectively). The median ratio between kidney uptake at 24 h evaluated on planar images and 3D-SPECT/CT is 0.45 (range:0.32-1.23). The comparison between hybrid and full 3D approach has been tested on one patient, resulting in a 1.6% underestimation with respect to full 3D (2D: 0.829 mGy/MBq, hybrid: 0.315 mGy/MBq, 3D: 0.320 mGy/MBq). Treatment safety has been confirmed, with a mean absorbed dose of 0.73 mGy/MBq (range:0.26-1.07) for kidneys, 0.56 mGy/MBq (0.33-2.63) for the parotid glands and 0.63 mGy/MBq (0.23-1.20) for submandibular glands, values in accordance with previously published data.

Introduction

Among peptide-receptor radionuclide therapies, 177Lu-PSMA-617 PRRT combines a short-range beta emitter 177Lu (1.9 mm maximum range in water, half-life 6.71 days) with a prostate-specific membrane antigen (PSMA) ligand. The overexpression of PSMA in 90-100% of local prostate cancer lesions and metastatic disease (lymph node and bone) is the key to this therapy. However, PSMA receptors are also expressed in different healthy tissues where high uptake is often observed during treatments. The main organs at risk are the kidneys, red marrow, salivary and lachrymal glands. The dose to these organs may reduce maximum injectable activity, impairing the t....

Access restricted. Please log in or start a trial to view this content.

Protocol

The dosimetry procedure was performed according to the treatment protocol "Radiometabolic Therapy (RMT) with 177Lu-PSMA-617 in advanced castration resistant prostate cancer (CRPC): efficacy and toxicity evaluation" (EUDRACT/RSO number: 2016-002732-32) (Figure 1). Selected patients underwent dosimetry evaluation based on performance status. All patients signed informed consent. Prior to treatment delivery, each patient underwent a 68Ga-PSMA-11 PET/CT whole body scan.

NOTE: It is important to underline that some steps are linked specifically to the scanner used.

1. ....

Access restricted. Please log in or start a trial to view this content.

Results

Dosimetry was performed for 10 patients (7 undergoing first treatment cycle, 3 second cycle).  Blood samples were acquired from all but 3 patients. One patient voided the bladder before the first post-infusion image acquisition. Injected activity was 5.5 GBq for 5 patients and 4.4 GBq for 5 patients.

With regard to curve fitting, mono or bi-exponential curve fitting was used for organ time-activity-curves. Bi-exponential curve f.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The method described enables whole body dosimetry to be performed for PRRT therapies and is a valid compromise between 2D whole-body and 3D dosimetry information in that it provides valuable information without significantly increasing image acquisition load. The method is also useful for the evaluation of the absorbed dose of overlapping structures and provides information on the structures lying outside the 3D SPCET/CT limited field of view.

The implementation of the methodology requires a h.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

Our thanks go to the professional figures involved in the protocol (i.e., physicians, physicists and nurses) and to the patients who agreed to take part in the study. We are also grateful to the medical radiology technicians of the Nuclear Medicine Unit for their help with protocol implementation: Valentina Mautone, Maria Caternicchia, Monia Pancisi, Daniela Fichera and Delia Bevilacqua. The authors acknowledge Alessandro Savini and Simone Marzoni for their help in the video recording. The work was partially supported by AIRC (Italian Association for Cancer Research, grant number: L2P1367 - L2P1520). The work was partially fi....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
177Lu EndolucinBetaITG - Isotopen Technologien München AG, Lichtenbergstrasse 1, 85748 Garching, Germany, info@itm.agRadiotracer 177Lu for therapy purpuse
Biograph mCT Flow PET/CTSiemens Healthineers, Erlangen, GermanyPET/CT scanner
C-Thru 57Co planar flood - Model MED3709Eckert & Ziegler, Strahlen- und Medizintechnik AG, Robert-Rössle-Str. 10, 13125 Berlin, Germany, info@ezag.deCalibration/planar source
Cylindrical phantom with spheric insertData Spectrum Corporation, 1605 East Club Boulevard, Durham NC 27704-3406, US, info@spect.comPhantom for SPECT/CT calibration
Discovery NM/CT 670 SPECT/CTInternational General Electric, General Electric Medical System, Haifa, IsraelSPECT/CT scanner
GalliaPharm 68Ge/68Ga GeneratorEckert & Ziegler, Strahlen- und Medizintechnik AG, Robert-Rössle-Str. 10, 13125 Berlin, Germany, info@ezag.de68Ge/68Ga Generator of 68Ga for imaging purposes
GammaVision v 6.08Ortec, Ametek - Advanced Measurement Technology, 801 South Illinois Avenue, Oak Ridge, Tennessee 37830, US, ortec.info@ametek.comGamma Spectorscopy software
High Purity Germanium HPGe, model GEM30P4-70Ortec, Ametek - Advanced Measurement Technology, 801 South Illinois Avenue, Oak Ridge, Tennessee 37830, US, ortec.info@ametek.comGamma spectometer
MimVista SoftwareMIM Software INC, Cleveland, OH 44122, USWorkstation
OLINDA/EXM v 1.1RADAR - RAdiation Dose Assessment Resource, West End Ave, Nashville, TN 37235, US (now commercially available as OLINDA/EXM v 2.0, Hermes Medical Solutions, Strandbergsgatan 16,
112 51 Stockholm, Sweden, info@hermesmedical.com)
Dosimetry software
PSMA 11ABX advanced biochemical compounds - Biomedizinische,Heinrich-Gläser-Straße 10-14, 01454 Radeberg, Germania, info@abx.deCarrier for 68Ga radiotracer
PSMA 617Endocyte Inc. (Headquarters), 3000 Kent Avenue, West Lafayette, IN 47906Carrier for 177Lu radiotracer
Xeleris4.0International General Electric, General Electric Medical System, Haifa, IsraelWorkstation

References

  1. Matteucci, F., et al. Reduction of 68Ga-PSMA renal uptake with mannitol infusion: preliminary results. European Journal of Nuclear Medicine and Molecular Imaging. , 1-6 (2017).
  2. Sarnelli, A., et al.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Absorbed Dose Estimation2D Planar Imaging3D SPECT/CT ImagingHybrid 2D+3D MethodOrgan Uptake AnalysisTime Activity CurveBlood Sample MeasurementAttenuation Correction