After implanting the telemeter into the pregnant mouse, we recorded the ECGs from pregnancy to lactation in a home cage. The sampling rate was set to 1 k/s. To compare the ECG of each physiological state of the mother mouse while avoiding the influence of circadian rhythm, the 10 min data from 23:32 to 23:42 on GD 17, parturition, PD 0, and PD 21 from the 2 h data file (Figure 3, Table 1) were analyzed. The time from 23:32 to 23:42 was chosen as it represents the 10 min before the birth of the first pup during parturition. This specific time period was selected to demonstrate the feasibility of performing data analysis during parturition when muscle contractions were present. During all analysis phases, the mouse exhibited both general behaviors (drinking, digging, food, self-grooming) and maternal behaviors (nest building, licking/grooming), as observed from 6 out of the 16 ethograms listed in Table 2.
The ECGs of the mother were recorded without interference at GD17 when the fetus was inside the body (Figure 3A) and during parturition when physical changes such as muscle contractions occurred (Figure 3B). Additionally, the ECGs were recorded stably from pup birth (PD 0) to PD 21 (Figure 3C,D) despite various nursing behaviors. ECG analysis showed that the heart rate decreased gradually while the RR interval increased gradually from GD 17 to PD 21 (Table 1). The HRV analysis showed that the LF/HF ratio increased sharply from PD 0 to PD 21 (Table 1).
The ethograms of maternal and general behaviors recorded along with the ECG were subdivided, as shown in Table 2. We also confirmed that ECGs could be measured without waveform disturbances when the mothers exhibited any behavior defined in Table 2, such as feeding (Figure 4A,C) and crouching (Figure 4B,D).

Figure 1: Telemetry implanted at gestation day 14 in mouse. (A) Two leads were connected to a telemeter. The black represents negative lead, and the white represents positive lead. (B) The negative and positive leads were bundled and placed in the neck. The telemeter was placed on the ventral side. (C) The lead was removed from the neck, and the SCM was exposed. (D) The telemetry was positioned on the ventral side. The SCM is represented in pink. The clavicle and xiphoid process are represented in gray. The black line indicates the negative lead. The orange line indicates the positive lead. The blue line represents the suture position. (E) The negative lead was connected to the SCM. The positive lead was connected around the xiphoid muscle. (F) All incisions (represented by the red circle) were closed using a 20 cm suture. (G) Video capturing setup using a drive recorder. Please click here to view a larger version of this figure.

Figure 2: ECG recorded using the data analysis software. (A) The ECG was recorded for 3 s. (B) ECG for each heartbeat. (C) Red dashed lines indicate areas where the ECG was not recorded. Please click here to view a larger version of this figure.

Figure 3: ECG during pregnancy, parturition, and lactation. The ECG results of the same mouse at the same time.(A) ECG at GD 17. (B) ECG during parturition. (C) ECG at PD 0. (D) ECG at PD 21. Please click here to view a larger version of this figure.

Figure 4: ECG recording during behavioral observation. ECGs were recorded during the ethogram construction of the same mouse at PD 6.(A) Image of the mother eating solid food. (B) Image of the mother crouching over her pups. (C) The ECG of the mother while eating food. (D) The ECG of the mother while crouching over their pups. Please click here to view a larger version of this figure.
Table 1: Heart rate variability analysis based on ECG from pregnancy to lactation. Heart rate variability (HRV) analysis was performed based on the ECGs data shown in Figure 3. All analyses were shown for the same mouse and at the same time (23:32-23:42). Average RR, the average of the beat intervals; Average Rate, the average rate of the beat; SDSD, the standard deviation of the difference between successive beat intervals; RMSSD, root mean square of successive RR interval differences; pRR50, the percentage of beat interval differences greater than a fix duration; Total, the power contained within the entire frequency range; VLF, very low frequency; LF, low frequency; HF, high frequency; SD1; standard deviation along the minor axis of the Poincare distribution; SD2, standard deviation along the major axis of the Poincare distribution. Please click here to download this Table.
Table 2: Defined ethograms. All ethograms were defined based on parameters such as posture, time spent, and the place they visited. Please click here to download this Table.