A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Electrophysiological Methods to Assess Peripheral Pain Block in an Anesthetized Rat

505 views

DOI:

10.3791/68740

November 21st, 2025

In This Article

Summary

Here, we present a method for assessing the activation and block of sensory axons in peripheral nerves in acute, anesthetized, in vivo rat experiments using two types of spinal electrophysiological measurements that can discriminate the activity of nerve fiber subtypes: Local Field Potentials and Wide Dynamic Range single neuron recordings.

Abstract

In vivo electrophysiological recordings from the lumbar region of the rat spine can be used to study the activation of sensory neural signals in the hindlimbs, as well as the efficacy of therapeutic interventions that interrupt ascending pain signals.

Here, we describe the surgical procedures (laminectomy and sciatic nerve exposure), data collection, and analysis of two complementary electrophysiological signals: local field potential recordings and wide dynamic range single neuron recordings. Both differentiate activation of nerve fiber subclasses based on conduction velocity relative to an electrical stimulation pulse.

Local field potentials (LFP) can differentiate between A α/β and C nerve fibers but cannot detect Aδ activity. They provide information about the global activation of the whole sciatic. Following electrical direct stimulation of the sciatic nerve using a J-cuff style bipolar electrode, area under the curve measurements of the two troughs corresponding to each component are calculated.

Wide dynamic range (WDR) single neuron recordings assess the activity of a subset of sciatic activation, and can differentiate Aα/β, Aδ, and C fiber types. Electrical stimulation can be applied directly to the sciatic as with LFP, or via needle electrodes placed in the plantar surface of the hindpaw. This higher-frequency signal yields high signal-to-noise action potential spikes. Spike counts within predefined latency windows reflect the level of activity of the various fiber types.

To date, these techniques have been used to assess the temporal properties of three different pain block modalities: Direct current electrical nerve block using a custom-made Carbon Separated Nerve Interface Electrode (CSINE), Kilohertz Frequency Alternating Current, and photobiomodulation using an 830 nm laser. This surgical preparation has been used for nerve block interventions for up to 5 h.

Introduction

Directly blocking pain signals in peripheral nerves prior to reaching the spinal cord has potential for several pain therapy applications, such as knee osteoarthritis and post-amputation phantom limb syndrome1,2,3,4. In general, such pain therapy interventions would reduce/eliminate the systemic side effects noted in current pharmaceutical anesthetics and analgesics1,2.

Two types of complementary electrophysiological measurements can be recorded from the l....

Access restricted. Please log in or start a trial to view this content.

Protocol

This protocol involving animal experiments was approved by the Institutional Animal Care and Use Committee (IACUC) of Case Western Reserve University (CWRU). Case Western Reserve University is an AAALAC-accredited institution and conforms to appropriate federal, state, and local laws and regulations, as well as institutional policies. Our research group was trained and certified by CWRU staff. When working on IACUC-approved protocols, we adhere to Public Health Service policy and the Guide for the Care and Use of Laboratory Animals (8th edition)32. This procudure is terminal and euthanasia would be triggered (through IACUC approved protocol) up....

Access restricted. Please log in or start a trial to view this content.

Results

The data generated using this protocol allow one to assess the relative amount of block for subclasses of sensory nerve fibers. It also allows the temporal properties of the block to be assessed; both the rate at which block in induced, and the rate of recovery following the cessation of the blocking stimulus35. For the LFP measurements the activation of fibers is determined by calculating the area under the curve for the specific time period corresponding to the fiber type of interest. In

Access restricted. Please log in or start a trial to view this content.

Discussion

This method describes the collection of two complementary electrophysiological signals that can be used to measure the efficacy of potentially therapeutic interventions to block sensory signals in peripheral nerves.

Local field potentials (LFP) can be recorded from the spinal dorsal columns using high impedance (1 MΩ) microelectrodes. They are used to measure the activation of the whole sciatic nerve; the LFP represents the responses of many cells, including excitatory postsynaptic poten.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported by NIH NINDS R01NS116009.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
1 x 8 multielectrode array, 500 µm spacing between shafts MicroprobesCustom productCustom microelectrode array 
14 G Angio catheterBencton DickinsonSKU: 381164, GTIN: 382903811649
8-channel bioamplifierWorld Precision InstrumentsISO-DAM8AHead stage
AmScope SM-6T series trinocular zoom stereo microscope 3.5-45x Magnification with articulating arm with ring lightAmscopeSM-8TW2-144SSurgical microscope
Data acquisition device Cambridge Electronic DesignPower1401-3A
Dumont #5 forcepsFine Science Tools11251-20
Friedman-Pearson Rongeurs (1mm cup size)Fine Science Tools16021-14
Harvard apparatus ventilatorHarvard Apparatus Model 683
Isoflurane, USPPiramel Critical Care66794-017-25
LaryngoscopeSarnova HC301-B802
Miller 00 laryngoscope bladeSarnova HC301-B5100-20
Paired subdermal needlesRhythmLinkRLSND121-1.013 mm stainless steel needle electrodes 
Rocuronium bromium, USPSolco43547-530-10
Spike2Cambridge Electronic Design
Square wave isolated pulse stimulator AM-SystemsModel 2100Biphasic rectangular isolated pulse stimulator
Stereotaxic platform  with adjustable base mounts with post and clampDavid Kopf InstrumentsModel 982
SureSite IV 22G x 1" safety catheter MedlineDYNA2210022 G intravenous catheter 
Syringe driverCole ParmerModel 74900
Ultra precise micro manipulator
10 micron resolution
David Kopf InstrumentsModel 961
Universal holderDavid Kopf InstrumentsModel 1772 Alternate 3D printed connector 
U-shaped stereotaxic frame David Kopf InstrumentsModel 1430
Vannas spring scissors - 2 mm cutting edgeFine Science Tools15000-03 
Vertebrae clamps David Kopf InstrumentsModel 986C 

References

  1. Paul, A. K., et al. Opioid analgesia and opioid-induced adverse effects:a review. Pharmaceuticals (Basel). 14 (11), 1091(2021).
  2. Guichard, L., et al. Opioid-induced hyperalgesia in patients with chronic pain:a systematic revie....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Tags

Peripheral Nerve BlockElectrophysiological RecordingSciatic Nerve StimulationLocal Field PotentialWide Dynamic RangeLaminectomy ProcedurePain Signal TransmissionCarbon Nerve ElectrodeDirect Current BlockRat Spinal Cord