Subclavian cardiac puncture is a simple, reliable method for collecting terminal blood in mice. It is easy to operate and ensures high-purity samples.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
* These authors contributed equally
Subclavian cardiac puncture is a simple, reliable method for collecting terminal blood in mice. It is easy to operate and ensures high-purity samples.
In experimental studies, mouse blood is a common experimental sample. However, there are still some challenges for the collection of large volumes of blood. The common methods of terminal large-volume blood collection include large-vessel blood collection and cardiac puncture collection. Large-vessel blood collection often requires surgery and is difficult to perform. In contrast, cardiac puncture is simple and easy to operate. However, there are also different methods for blood sampling by cardiac puncture. Different methods have different puncture sites, and each has its advantages and disadvantages. In this study, we provided a detailed examination of the subclavian cardiac puncture technique for blood collection, emphasizing its ease of operation and its ability to yield high-quality samples. This study validates that the subclavian cardiac puncture blood collection method can recover approximately 50% of the total blood volume and significantly reduce tissue fluid contamination. The method can be applied to multiple research disciplines, including immunology, toxicology, and metabolic studies.
Blood collection from mice is essential in scientific research and various other fields1. Non-terminal blood collection methods, including tail vein, femoral vein, and submandibular sampling, provide advantages in repeatability, yet they carry potential risks of tissue damage, animal stress, and compromised sample quality2. In terminal procedures, cardiac puncture and large-vessel blood collection are commonly used to obtain large blood samples, typically yielding approximately 50% of the total blood volume3,4.
Large-vessel blood collection requires a surgical incision and carries a high bleeding risk. In contrast, cardiac puncture is minimally invasive, reduces animal stress, and is relatively simple to perform5. By directly collecting blood from the heart, this method ensures a swift blood flow, minimizing the risk of coagulation and improving sample quality6. As a result, cardiac puncture is the preferred technique for terminal experiments7.
In this study, we employed the subclavian approach for cardiac puncture. Compared with traditional puncture methods, this approach offers a more precise needle trajectory. The needle sequentially traverses the skin, subcutaneous tissue, and thoracic muscles, enters the thoracic cavity, and reaches the cardiac chamber for blood collection. Abdominal puncture, for instance, may cause liver injury, which can alter blood components such as serum proteins, coagulation factors, and metabolic enzymes8.
Additionally, liver damage can lead to elevated alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels, further interfering with experimental results9. In practice, the subclavian approach is particularly suitable for experiments that require intact liver tissue, precise assessment of hepatic function, or sensitive measurement of proteins and metabolites. However, it is less suitable for very young or small mice, where anatomical structures are difficult to visualize, and for studies requiring intact cardiac tissue, as puncture may compromise subsequent analyses.
Access restricted. Please log in or start a trial to view this content.
All animal procedures in this study were approved by the Institutional Animal Care and Use Committee (IACUC) and conducted in accordance with the Guidelines for the Care and Use of Laboratory Animals in China. The study strictly adhered to ethical regulations for animal experiments and was approved by the Animal Ethics Committee (Approval Number: YD20250310007). A total of 14 healthy C57BL/6 mice (seven males and seven females) were used in this study, with body weights ranging from 21 g to 29 g. The animals were housed at the Laboratory Animal Center of Yanbian University under standard laboratory conditions.
1. Animals
2. Experimental preparation
3. Mouse preparation and positioning
4. Puncture procedure
5. Blood collection
6. Sample processing
7. Sample testing
Access restricted. Please log in or start a trial to view this content.
In this study, we conducted repeated experiments on 14 C57BL/6 mice (21-29 g), with seven males and seven females. Studies report that the estimated blood volume in an adult mouse is 55 to 70 mL/kg body weight10. The blood volume collected per session ranged from 700 to 1,200 µL, accounting for approximately 50% of the total circulating blood volume (Figure 5). The operation time per session ranged from 60 to 80 s. No hemolysis or sample conta...
Access restricted. Please log in or start a trial to view this content.
Cardiac puncture is a widely used terminal blood collection method in mouse experiments, ideal for obtaining large volumes of blood while minimizing contamination from tissue fluids, thus ensuring sample purity12. Compared to other blood collection techniques, cardiac puncture is straightforward, requiring only a single procedure, which helps reduce stress in experimental animals. In this study, we employed the subclavian puncture method. This approach features a well-defined needle path, minimizi...
Access restricted. Please log in or start a trial to view this content.
The authors have no conflicts of interest to disclose.
This work was funded by grants from the National Natural Science Foundation of China (No. 82360065) and the Natural Science Foundation of Jilin Province (Grant No. YDZJ202501ZYTS166). The authors thank Gang Chen from Yanbian University for help with the cardiac blood sampling methods.
Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| 1.5 mL Tubes | Labselect | MCT-001-150-S | |
| 15 mL Conical Tubes | As One Corp | 1-3500-01 | |
| 2 mL Syringe | Jiangxi Fenglin | 0.5x20RWLB | |
| 4 °C Centrifuge | Eppendorf | 5409CP202285 | |
| 75% Ethanol | Nanjing Reagent | C069156931 | |
| Alanine Aminotransferase (ALT/GPT) Activity Assay Kit | Elabscience® | E-BC-K235-M | |
| Aspartate Aminotransferase (AST/GOT) Activity Assay Kit | Elabscience® | E-BC-K236-M | |
| Electronic Compact Scale | YUHENG | YH-400A | |
| Heparin | solarbio | H8060 | |
| Inhalation Anesthesia Machine | Mindray | 10-1020 | |
| Isoflurane | RWD Life Science | R510-22-16 | |
| Pipette | Eppendorf | 3111 000 840 | |
| Pipette tips | Axygen® | MTX-1250-C |