-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Neuroscience
Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale E...
Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale E...
JoVE Journal
Neuroscience
This content is Free Access.
JoVE Journal Neuroscience
Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale Entropy

Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale Entropy

Full Text
34,343 Views
11:15 min
June 27, 2013

DOI: 10.3791/50131-v

Jennifer J. Heisz1, Anthony R. McIntosh1

1Rotman Research Institute,Baycrest

Neuroimaging researchers typically consider the brain's response as the mean activity across repeated experimental trials and disregard signal variability over time as "noise". However, it is becoming clear that there is signal in that noise. This article describes the novel method of multiscale entropy for quantifying brain signal variability in the time domain.

The overall goal of this procedure is to quantify the variability of an EEG time series and relate that variability to the information processing capacity of the underlying neural system. This is accomplished by first acquiring high quality EEG recordings of the brain's response. The second step is to pre-process the data to remove any artifacts.

Next, the statistics of interest are extracted. Here we will contrast the novel application of multi-scale entropy with more traditional methods of mean amplitude and spectral power. The final step is to analyze the statistical significance of the results and interpret the data.

This step can be facilitated by using data-driven multi-variate approaches like partial lease square's analysis. Ultimately, multi-scale entropy is used to show how a sequence of changes in the spatial temporal pattern across multiple times scales contributes to specific cognitive operations. The advantage to using MSC over existing methods like mean amplitude or spectra power, is that MSC is sensitive to the non-linearities in the data.

These non-linear dynamics reflect transitions or bifurcations between the micro states of a network, which is important for information exchange across a distributed network of brain regions. Demonstrating this procedure will be Christina Backer from the ERP lab at the Rotman Research Institute. First, explain the experimental procedures to the participant and obtain informed consent.

Clean the area where the dropdown electrodes will be placed using an alcohol swab. Place some gel on the electrode. Take off the papers from the skin side and place the electrodes on the participant to identify eye movement artifacts.

Place an electrode on the lateral junction of the upper and lower of the eyelid. Place another electrode on the center of the orbital ridge, approximately one centimeter below the eye and in line with the pupil. Repeat for the other eye.

Measure the participant's head circumference and choose the appropriate electrode cap size following the internationally recognized 10 20 system. For electrode placement, measure the distance from Indian Ian along the midline and divide by 10%Using that number. Measure up from NAS and mark.

Align the electrode cap position FP with this mark and pull the cap back. Make sure that the center of the cap is in line with the nose. Measure nasn to cz and confirm that this distance is half the distance from NAS to Indian.

Then tighten the chin strap and place gauze under the strap for comfort if necessary. Now, put the gel filled blunt point syringe in the electrode holders to create a conductive column of gel. Start in contact with the scalp, then squeeze and pull back.

Note that the application of too much gel may bridge the signals of neighboring electrodes. Next, fix active electrodes into the electrode holders. Then position the subject in front of the monitor at the appropriate distance.

For the experiment, ask the participant to remain still emphasizing the importance of minimizing eye movements and blinks. For a clean recording, examine the electrode connections and EEG signal quality on the acquisition computer. If there is a problem with a particular electrode, take out that electrode and reapply gel to adjust impedances at that site after experimentation, but before extracting the particular statistic of interest.

Pre-process the continuous EEG data to remove artifacts using standard procedures of filtering and artifact Rejection. Event related potential analysis captures the synchronous brain activity that is phase lock to the onset of a stimulus Time lock the brain's response to the onset of a salient event, and then average over many like events. To increase the signal to noise ratio, identify the peak amplitude and latency of the ERP component for each subject, Spectra power quantifies the relative contribution of a frequency to a particular EEG signal.

Use Fourier analysis to transform the EEG signal from the time domain to the frequency domain and decompose the signal into its component sine waves of varying frequencies. Multi-scale entropy is an information theoretic metric that captures the variability of neuro electrical signals over time and across multiple times.Scales. Use the algorithm at PhysioNet to compute multi-scale entropy in two steps.

In the first step, progressively downs. Sample the signal for each trial and condition timescale. One represents the original signal.

Create subsequent timescales by first dividing the original signal into non-overlapping windows of the timescale length. Then average the data points within each window. For example, to create timescale two average together.

The first two points, the next two points, and so on. To create timescale three average together the first three points, the next three points and so on. By representing the original signal at various timescales, neural processes that may be unfolding at different rates can be analyzed.

The second step calculates sample entropy for each course. Grained time series. This provides an estimate of the complexity of the brain's response at the different timescales.

Regular signals have lower sample entropy than more stochastic signals. In this example, the pattern length M is set to two. This means that the time series will be represented as a ratio of two versus three point sequence matches.

Parameter R is the similarity criterion. Data points that lie within this amplitude range have similar values and thus are said to match. For details on setting parameters, consult the text protocol to calculate sample entropy for this simulated time series.

Begin with the first two components. Sequence pattern, red orange, first count the number of times the red orange sequence pattern occurs in the time series. There are 10 matches for this.

Two components sequence. Second count the number of times the first three components. Sequence pattern, red, orange, purple occurs in the time series.

There are five matches for this. Three component sequence. Continue with the same operations for the next two component sequence, orange, purple, and the next three component sequence, orange, purple, green of the time series.

Add the number of two component matches and three component matches for these sequences to the previous values. Repeat for all other sequence matches in the time series to determine the total ratio of two component matches to three component matches. Sample entropy is the natural logarithm of this ratio.

These data show condition differences in ERP spectral power and entropy contrasting the initial versus repeated presentation of facial photographs. In this example, all measures converged to reveal the same effect of decrease in sample entropy that accompanies face repetition. This decrease in complexity suggests that the functional network engaged is simpler and processing less information.

These statistical results are derived from the multi-variate analysis of partial lease squares of ERP spectral power and multi-scale entropy for faces associated with different levels of familiarity. The contrast shows that the ERP amplitude distinguished new faces from familiar faces, but not among the familiar faces that varied in amount of prior exposure. Spectral power distinguished faces according to the familiarity, but did not accurately distinguish between faces of low and medium familiarity.

Multi-scale entropy was most sensitive to the condition differences. Sample entropy values increased with increasing face familiarity. These image plots capture the spatial temporal distribution of the condition effect.

Interestingly, Multiscale entropy revealed unique information that was not obtained by the more traditional analyses of ERP or spectral power. This divergence of multi-scale entropy suggests that the conditions differ with respect to non-linear aspects of their network dynamics possibly involving the interactions between frequency bands. This novel analytical tool helps us to capture new information about the neural network dynamics, helping to move us away from characterizing mental function in terms of static states and towards understanding the fluid unfolding of processes that link to human cognition.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

EEG NeuroimagingEvent-related PotentialsSpectral PowerMultiscale EntropyBrain Signal VariabilityNeural Network Dynamics

Related Videos

Recording Human Electrocorticographic (ECoG) Signals for Neuroscientific Research and Real-time Functional Cortical Mapping

13:32

Recording Human Electrocorticographic (ECoG) Signals for Neuroscientific Research and Real-time Functional Cortical Mapping

Related Videos

26.7K Views

Simultaneous Electroencephalography and Magnetoencephalography to Identify Seizure-Prone Brain Regions

04:40

Simultaneous Electroencephalography and Magnetoencephalography to Identify Seizure-Prone Brain Regions

Related Videos

557 Views

Investigating the Effects of Antipsychotics and Schizotypy on the N400 Using Event-Related Potentials and Semantic Categorization

12:00

Investigating the Effects of Antipsychotics and Schizotypy on the N400 Using Event-Related Potentials and Semantic Categorization

Related Videos

13.3K Views

Infant Auditory Processing and Event-related Brain Oscillations

06:34

Infant Auditory Processing and Event-related Brain Oscillations

Related Videos

16.9K Views

Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex

09:00

Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex

Related Videos

12.8K Views

Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging

11:28

Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging

Related Videos

12.2K Views

Analyzing Neural Activity and Connectivity Using Intracranial EEG Data with SPM Software

06:50

Analyzing Neural Activity and Connectivity Using Intracranial EEG Data with SPM Software

Related Videos

9.9K Views

Statistical Modelling of Cortical Connectivity Using Non-invasive Electroencephalograms

08:51

Statistical Modelling of Cortical Connectivity Using Non-invasive Electroencephalograms

Related Videos

6K Views

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data

04:13

Computer-based Multitaper Spectrogram Program for Electroencephalographic Data

Related Videos

12.8K Views

Event Related Potentials (ERPs) and other EEG Based Methods for Extracting Biomarkers of Brain Dysfunction: Examples from Pediatric Attention Deficit/Hyperactivity Disorder (ADHD)

10:02

Event Related Potentials (ERPs) and other EEG Based Methods for Extracting Biomarkers of Brain Dysfunction: Examples from Pediatric Attention Deficit/Hyperactivity Disorder (ADHD)

Related Videos

16.6K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code