To describe the fabrication and assembly of a vertically stacked dentin–pulp complex organ-on-a-chip device incorporating a human dentin disc and photolithography-fabricated microchannels, followed by dental pulp stem cell seeding and culture.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
To describe the fabrication and assembly of a vertically stacked dentin–pulp complex organ-on-a-chip device incorporating a human dentin disc and photolithography-fabricated microchannels, followed by dental pulp stem cell seeding and culture.
Conventional preclinical models used in dental research, including animal models and static cell cultures, present important limitations in reproducing the physiological conditions of the dentin–pulp interface and predicting human biological responses to dental biomaterials. Organ-on-a-chip (OoC) technology provides an alternative approach by enabling the recreation of tissue-specific microenvironments within controlled microfluidic systems. This manuscript describes a step-by-step protocol for the fabrication and assembly of a dentin–pulp complex OoC device incorporating a human dentin disc within a three-layer polydimethylsiloxane (PDMS) microfluidic platform. The protocol includes dentin disc preparation, fabrication of microstructured molds using photolithography, PDMS casting and curing, plasma-assisted layer bonding, device assembly, leak testing, and dental pulp stem cell seeding under static culture conditions. Critical fabrication parameters influencing device performance are discussed, including control of PDMS layer thickness, plasma surface treatment, and integration of the dentin disc within the device to minimize leakage. Cell adhesion and viability within the device were evaluated using scanning electron microscopy and confocal live/dead staining. Representative results demonstrate successful integration of the dentin disc within the microfluidic assembly, maintenance of leak-free conditions, and adhesion of viable dental pulp stem cells to the dentin surface. This protocol provides a reproducible approach for the fabrication of a dentin–pulp complex OoC platform that may support future studies investigating cellular responses to dental biomaterials and microenvironmental stimuli.
Animal experimentation has long been instrumental in advancing the understanding of pathological and physiological processes and has played a central role in the early stages of drug development1. Over the course of the 20th century, human life expectancy increased substantially, and while it is not possible to precisely quantify the extent to which this improvement is attributable solely to animal research, it is widely acknowledged that many contemporary medical treatments have been developed or validated using animal models2. Notable examples include the development of vaccines against poliomyelitis, measles, and hepa....
Access restricted. Please log in or start a trial to view this content.
The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of Universidad de La Frontera for studies involving human samples.
1. Acquisition of dentin disk
NOTE: Prepare the device design before beginning the protocol (Figure 1A–1C).
Access restricted. Please log in or start a trial to view this content.
Successful fabrication of the tooth-on-a-chip device followed the workflow illustrated in Figure 1A–1I, including dentin disc preparation (Figure 1D), fabrication of the photolithography-derived mold (Figure 1E), removal of cured PDMS layers (Figure 1F), plasma activation prior to bonding (Figure 1G), assembly of the final device (Figur.......
Access restricted. Please log in or start a trial to view this content.
This study describes a step-by-step protocol for the fabrication of a vertically stacked tooth-on-a-chip device incorporating dentin and dental pulp stem cells and demonstrates representative cell adhesion and viability within the device under static culture conditions. The protocol was developed to provide a reproducible workflow for the fabrication and assembly of a dentin–pulp complex OoC platform suitable for in vitro studies of the dentin interface. The establishment of such a workflow is particularly signific.......
Access restricted. Please log in or start a trial to view this content.
The authors declare no competing financial interests and have no conflicts of interest to disclose.
This work was supported by Project DIM24-0004 and Project PP24-0031, Dirección de Investigación, Universidad de La Frontera; FONDECYT Regular No. 1260116; and FONDECYT de Iniciación No. 11230701, National Agency for Research and Development (ANID), Chile.
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| Biological and chemical materials | |||
| Acetone | ExpertQ | SOLV 8 | Silicon wafer cleaning |
| Alpha MEM culture medium | Cytiva | SH30265.02 | Dental pulp stem cell culture medium |
| Chloramine (0.5%) | Merck | 7080-50-4 | Storage solution for dentin discs |
| Dental pulp stem cells | Not Applicable | Not Applicable | Primary cell culture. See Steps 3.2.1 and 3.2.2 |
| EDTA (10%) | Winkler | N2222158E | Smear layer removal |
| Epoxy-based negative photoresist | Gersteltec | GM1060 | Photolithography mold fabrication |
| Glutaraldehyde (2.5%) in 0.1 M Sorensen’s phosphate buffer | Sigma-Aldrich | 210908-06 | SEM fixation |
| Healthy human teeth (molars or premolars) | Not Applicable | Not Applicable | Human sample |
| Isopropanol | ExpertQ | SOLV 16 | Wafer cleaning, development stopping, and PDMS cleaning |
| LIVE/DEAD Viability Kit | Sigma-Aldrich | 451 | Fluorescence viability staining. |
| PBS (phosphate-buffered saline) | Corning | 46-013-CM | Washing and leakage testing |
| PDMS base and curing agent (polydimethylsiloxane) | Dow | Sylgard 184 | Device fabrication |
| PGMEA | Sigma Aldrich | 484431 | Photoresist development |
| Trypan blue | Sigma Aldrich | T8154-100ml | Cell viability assessment |
| Trypsin | Corning | 25-053-CI | Cell detachment |
| Ultrapure water | Cytiva | SH30529.01 | Washing solution |
| Consumables and labware | |||
| 19G syringe needles | Vmatic | VCB19050 | Connection of device with micropump or syringe |
| Biopsy punch (diameter: 1 mm) | Harris Unicore | WHAWB100073 | Inlet and outlet port fabrication |
| Cutting mat | Nicecool | Not Applicable | Surface protection during punching |
| Dental finishing discs (e.g., Sof-Lex) | 3M | Sof-Lex | Dentin polishing |
| Female Luer-to-barbed adapters | Runze Fluidics | RH-M016 | Tubing connection |
| Glass or plastic mixing stick | Duran | Not Applicable | PDMS mixing |
| Hypodermic syringes | Cranberry | pc-12246 | Cell seeding and leakage testing |
| Lint-free sterile gauze | Linderson | Not Applicable | Removal of punching debris |
| Male Luer adapters | Runze Fluidics | RH-G016 | Tubing connection |
| Mixing vessel | Duran | Not Applicable | PDMS preparation |
| Petri dish (140 mm × 20 mm) | Deltalab | 2000219 | Cell culture/incubation |
| Polytetrafluoroethylene base | CCTVal | Not Applicable | Intermediate dentin layer fabrication |
| Silicon wafer | Jiaozuo Commercial FineWin | Not Applicable | Mold fabrication |
| Silicone tube | Runze Fluidics | 96421 | Fluidic connection |
| T75 flask | Corning | 353136 | Dental pulp stem cell expansion |
| Well plate | SPL Life Sciences | 30006 | Confocal staining and imaging preparation |
| Equipment and instruments | |||
| Air dryer | METALPLAN | TITAN-040 | Compressed air drying |
| Compressed air source | SCHULZ | CSD-18.1 | Mold and surface cleaning |
| Confocal microscope | Olympus | Not Applicable | Model: FV1000 |
| Direct laser lithography system | Heidelberg | uPG 101 | Photoresist exposure |
| Environmental scanning electron microscope | Hitachi | Not Applicable | Model: Quanta 400 |
| High-speed handpiece | Nakanishi | Not Applicable | Model: Pana-max2 |
| Hot plate | LabTech | EH20A Plus | Wafer bake and photoresist bake |
| Laminar flow cabinet | BioBase | BBS8V1708313D | Device sterilization |
| Microfluidic pump | New Era | Not Applicable | Model: 1002X-ES. Leak testing at 10 µL/min |
| Microstructured mold (fabricated via photolithography) | CCTVal | Not Applicable | See Step 2.2 for mold fabrication specifications |
| Oven or incubator | Memmert | UN110 | PDMS curing at 50°C and bond consolidation at 75°C |
| Vacuum Plasma Cleaning Chamber | Fari Plasma | GD-5 | Wafer plasma activation |
| Handheld Corona Plasma | Aurora Pro Scientific | APS-CD-20AC | PDMS plasma activation |
| Ultrasonicator | Elma Sonic | S 10 (H) | Wafer cleaning |
| Vacuum chamber or desiccator (250 mm) | Winglass | Not Applicable | PDMS degassing |
| Vacuum pump | ROCKER | 300 | PDMS degassing |
Access restricted. Please log in or start a trial to view this content.
This article has been published
Video Coming Soon