Automated Myography

Automated myography is a technique for measuring the mechanical responses of isolated blood vessels, providing quantitative insight into vascular function and disease. In an automated wire myograph, a vessel segment is mounted on wires in a temperature-controlled physiological solution, while sensors and software record changes in tension as the vessel contracts or relaxes in response to drugs, agonists, or altered conditions. This standardized approach supports analysis of vascular reactivity, endothelial function, and smooth-muscle performance. In medicine, automated myography helps evaluate cardiovascular mechanisms, compare therapeutic compounds, and identify abnormalities associated with hypertension, atherosclerosis, and other vascular disorders.

Automated Myography - Related Videos

Research

JoVE Journal - Medicine

Mesenteric Artery Contraction and Relaxation Studies Using Automated Wire Myography

0 Views •

Cited by 37 •

2011

An automated myography method for force measurements in isolated mesenteric arteries is described. It employs a Mulvany-Halpern Auto Dual Wire Myograph 510A to determine responses to phenylephrine and extracellular calcium. The method allows consistent determination of isometric responses to agonists in small vessels of diameters of 60 - 300 μm, independently.

Assessing Murine Resistance Artery Function Using Pressure Myography

0 Views •

Cited by 18 •

2013

In pressure myography, an intact small segment of a vessel is mounted onto two small cannulas and pressurized to a suitable luminal pressure. Here, we describe the method to measure vasorelaxation response of the mouse 3rd order mesenteric arteries in c57 and sGCα1-/- mice using pressure myography.

Exploring Arterial Smooth Muscle Kv7 Potassium Channel Function using Patch Clamp Electrophysiology and Pressure Myography

0 Views •

Cited by 8 •

2012

Measurements of Kv7 (KCNQ) potassium channel activity in isolated arterial myocytes (using patch clamp electrophysiological techniques) in parallel with measurements of constrictor/dilator responses (using pressure myography) can reveal important information about the roles of Kv7 channels in vascular smooth muscle physiology and pharmacology.

Automated Acoustic Dispensing for the Serial Dilution of Peptide Agonists in Potency Determination Assays

0 Views •

Cited by 1 •

2016

Peptide adsorption to plasticware during traditional tip-based serial dilutions can significantly impact potency determination and confound the understanding of structure-activity relationships used for lead identification and lead optimization phases of drug discovery. Here methods for automated acoustic non-contact serial dilution of peptide samples are described.

Assessing Myogenic Response and Vasoactivity In Resistance Mesenteric Arteries Using Pressure Myography

0 Views •

Cited by 24 •

2015

Pressure myography is used to assess vasoactivity of small arteries that develop sustained constriction when pressurized. This manuscript provides a detailed protocol to assess in isolated segments of small mesenteric arteries from rats, vasoactivity and the effect of intraluminal pressure on vascular diameter.