Intraocular Lens Rotation

Intraocular lens rotation is the postoperative turning of an implanted artificial lens around its optical axis inside the eye, a clinically important event because it can alter visual correction and lens positioning. Rotation occurs when forces within the capsular bag, including interactions among the lens, capsule, haptics, and surrounding zonular support, change the lens’s orientation during healing or after implantation. It is particularly relevant for toric intraocular lenses, whose astigmatism-correcting effect depends on alignment with the intended meridian. Clinical evaluation uses eye examinations and imaging to assess orientation, while significant misalignment may require surgical repositioning.

Intraocular Lens Rotation - Related Videos

Research

JoVE Journal - Medicine

Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries

0 Views •

Cited by 1 •

2023

The present protocol describes removing residual epithelial cells by rotating the intraocular lens in extracapsular cataract surgery without extra tools for preventing posterior capsular opacification.

Research

JoVE Journal - Chemistry
Free Sample

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application

0 Views •

Cited by 8 •

2019

This study describes synthetic routes for aminopropyl-terminated polydimethylsiloxanes and polydimethyl-methyl-phenyl-siloxane-block copolymers and for soft polysiloxane-based urea (PSU) elastomers. It presents the application of PSUs as accommodating an intraocular lens. An evaluation method for in vitro cytotoxicity is also described.

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs

0 Views •

Cited by 59 •

2016

Rabbits are widely used to study the pharmacokinetics of intraocular drugs. We describe a method for conducting pharmacokinetic studies of intraocular drugs using rabbit eyes.

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

0 Views •

Cited by 2 •

2017

This protocol describes the scanning light scattering profiler (SLSP) that enables the full-angle quantitative evaluation of forward and backward scattering of light from intraocular lenses (IOLs) using goniophotometer principles.

Induction of Elevated Intraocular Pressure in a Rat Model

0 Views •

2025

Source: Lani-Louzada, R., et al., Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents. J. Vis. Exp. (2022)This video demonstrates the induction and monitoring of elevated intraocular pressure (IOP) in a rat model. The process involves cauterizing the limbal blood vessels, resulting in vessel occlusion and elevated IOP. The rat is then allowed to recover, and IOP is regularly monitored in both the experimental and control eyes for comparison.

View All Results

FAQs

Related Topics