Atomic Force Microscopy to Visualize Phage–Antigen Interactions

0 views • 3:04 min • July 31st, 2026

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Take a cleaved mica surface, a flat substrate for nanoscale imaging.
Add a target antigen to the mica. Incubate to enable non-covalent binding of antigen to the mica surface.
Wash with water to remove unbound antigen.
Add a phage mixture containing clones that display different antibody fragments and incubate.
Antigen-specific phages bind to the immobilized antigen through displayed antibody fragments.
Wash to retain only high-affinity phage interactions. Air-dry to stabilize the complexes.
Place the sample under a tapping-mode atomic force microscope, or AFM.
Align the laser beam onto the cantilever with a nanometer-scale tip and initiate scanning.
The tip oscillates and taps the mica surface. Bound phage particles cause height changes that deflect the cantilever, shifting the reflected laser beam.
This shift is detected by a photodetector, generating high-resolution topographic images.
In these images, phages appear as long bright structures, indicating phage–antigen interactions.
To visualize phage binding using AFM, add 10 to 20 microliters of the target antigen to cleaved mica and incubate for 5 to 10 minutes. Wash the mica five times with water. Then, add 10 to 20 microliters of the phages to the mica and incubate for 5 to 10 minutes. Wash the mica another five times with water and allow to air dry.
Execute the AFM imaging process using AFM tapping mode with a Nanoscope IIIa controller in air at room temperature. The silicon AFM probes have a resonant frequency of 300 kilohertz and a spring constant of 40 newtons per meter. Insert the AFM tip into the tip loader. Attach the tip loader to the AFM microscope.
Place the sample under the AFM microscope. Use the knobs to align the laser onto the AFM tip.
Set the scan rate to 3.05 hertz and the scan resolution to 512 samples per line. Auto-Tune the machine to optimize the silica vibration frequency of the tip. Initiate sample scanning.
The tip will scan the surface of the mica, measuring the height of the bound phage. The phages are the long white lines

09:40

噬菌体型组学:生理途径来表征新型病毒蛋白

Related Videos

0 Views

08:51

原子力显微镜与红外光谱相结合,作为探测单一细菌化学的工具

Related Videos

0 Views

05:34

接触模式原子力显微镜作为形态观察和细菌细胞损伤分析的快速技术

Related Videos

0 Views

10:03

原子力显微镜成像的细菌固定化

Related Videos

0 Views

08:30

重组DNA和蛋白质复合物,用原子力显微镜的可视化

Related Videos

0 Views

06:10

在细胞命运 E.大肠杆菌

Related Videos

0 Views

05:09

静态原子力显微镜,用于可视化和表征组装的核小体

Related Videos

0 Views

05:31

单病毒原子力显微镜和超分辨率荧光成像的样品制备

Related Videos

0 Views

14:13

冲红灯光感受器原子力显微镜使用PeakForce定量纳米机械性能映射

Related Videos

0 Views

13:31

新型原子力显微镜基于生物淘选的形态特殊试剂对TDP-43变型肌萎缩侧索硬化症隔离

Related Videos

0 Views

Last updated: 1 August 2026