-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

CN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
<<<<<<< HEAD
K12 Schools
Biopharma
=======
K12 Schools
>>>>>>> dee1fd4 (fixed header link)

Language

zh_CN

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Neuroscience
Measurement of Oxygen Consumption Rate in Acute Striatal Slices from Adult Mice
Measurement of Oxygen Consumption Rate in Acute Striatal Slices from Adult Mice
JoVE Journal
Neuroscience
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Neuroscience
Measurement of Oxygen Consumption Rate in Acute Striatal Slices from Adult Mice

Measurement of Oxygen Consumption Rate in Acute Striatal Slices from Adult Mice

Full Text
4,985 Views
07:41 min
June 8, 2022

DOI: 10.3791/63379-v

Lianteng Zhi1, Jingyu Zhao1, David Jaffe1, Yuanxin Chen1, Ninghan Wang1,2, Qi Qin1, Erin L. Seifert3, Chenjian Li4, Hui Zhang1

1Department of Neuroscience,Thomas Jefferson University, 2School of Biomedical Engineering,Drexel University, 3Department of Pathology, MitoCare Center,Thomas Jefferson University, 4School of Life Sciences,Peking University

Overview

This study presents a novel method for measuring oxygen consumption rate (OCR) in acute striatal slices from adult mice using a Seahorse XF analyzer. This approach aims to provide a more physiologically relevant assessment of mitochondrial function compared to traditional methods, especially for disease models like Parkinson's and Huntington's diseases.

Key Study Components

Area of Science

  • Neuroscience
  • Mitochondrial function
  • Disease modeling

Background

  • Oxygen consumption rate is an established indicator of mitochondrial function.
  • Acute striatal slices closely approximate physiological conditions.
  • Current methods may lack relevance to in vivo cellular environments.
  • The technique may enhance understanding of neurodegenerative diseases.

Purpose of Study

  • To develop a more physiologically relevant method for measuring OCR.
  • To investigate mitochondrial function in acute brain slices.
  • To support research into disease mechanisms in neurodegenerative disorders.

Methods Used

  • Utilized Seahorse XF analyzer for OCR measurement.
  • Focused on acute striatal slices from adult mice.
  • Provided protocols for slice preparation, incubation, and measurement.
  • Highlighted calibration and setup steps for the assay.

Main Results

  • Stable basal respiration rates were observed across different slice conditions.
  • OCR measurements demonstrated proportional relationships to slice volume.
  • Mitochondrial coupling efficiency was highest at specific slice thickness and punch size.
  • Differential OCR findings were noted between knockout and wild-type mice.

Conclusions

  • This method enhances the ability to study mitochondrial function in a biologically relevant context.
  • May lead to better insights into neurodegenerative disease mechanisms.
  • Supports future research and therapeutic strategies in mitochondrial-related disorders.

Frequently Asked Questions

What are the advantages of using acute striatal slices?
Acute striatal slices provide a more accurate representation of the physiological environment compared to isolated mitochondria or cultured cells, allowing for better assessment of cellular function.
What types of data can be obtained through this method?
The method allows for direct measurements of oxygen consumption rates, which are indicative of mitochondrial function and can reveal insights into cellular metabolism in the context of disease.
How is the sample preparation process conducted?
The preparation involves delicately dissecting brain tissue, slicing it to a specified thickness, and incubating it in a respiration buffer prior to OCR measurement.
Can this method be adapted to study other brain regions?
The methodology can potentially be applied to other brain regions, allowing researchers to explore mitochondrial function across various neuronal environments.
What limitations should researchers be aware of?
Factors such as slice thickness, incubation conditions, and the age of the mice can influence the results and should be carefully controlled for consistency.
How does this research impact our understanding of neurodegenerative diseases?
By enabling more physiologically relevant assessments, this research can help elucidate mitochondrial dysfunctions associated with neurodegenerative diseases like Parkinson's and Huntington's disease.

Oxygen consumption rate (OCR) is a common proxy for mitochondrial function and can be used to study different disease models. We developed a new method using a Seahorse XF analyzer to directly measure the OCR in acute striatal slices from adult mice that is more physiologically relevant than other methods.

We developed a new method using a seahorse XF analyzer to directly measure the oxygen consumption rate. But common proxy for mitochondrial function in acute slide slice from adult mice. This method measures a cellular by energetics in punctures from anatomically defined brain structures.

Using acute slices more closely mimics the physiological cellular environment which cannot be achieved the ways isolated mitochondrial or culture cells. This method will be of broad interest to researchers working in the field of Parkinson's disease and Huntington's disease. To begin, open the extracellular flux assay kit and remove both the sensor cartridge and the utility plate.

Then place the sensor cartridge aside and do not touch the sensors. Next, add 600 microliters of calibrate solution to each wall of the utility plate. Place the sensor cartridge on top of the utility plate and submerge the sensors in the calibrate solution, ensuring that the triangular notch of the utility and sensor cartridge plate are correctly aligned.

Afterward, seal the extracellular flux assay kit with sealing film to prevent evaporation of the calibrate solution and then place it in a 37 degree Celsius incubator not supplemented with carbon dioxide or oxygen, overnight. Open the eyelet capture micro plate and take out the eyelet plate for tissue sitting. Then warm an appropriate volume of pre-oxygenated modified artificial cerebral spinal fluid buffer to 37 degree Celsius in a 50 milliliter tube.

Next add BSA to a final concentration of four milligrams per milliliter to prepare the respiration buffer. Add 625 microliters of respiration buffer to each well of the eyelet plate carefully while avoiding shaking the plate, ensuring no air bubbles are present in the buffer of each well. Immediately dissect the brain in 10 milliliters of ice-cold pre-oxygenated cutting solution.

Then, using a vibratome section coronal striatal slices, following the manufacturer's instruction at a thickness of 150 micrometer in ice-cold pre-oxygenated cutting solution. Next, recover the slices in 50 milliliters of oxygenated artificial cerebral spinal fluid. And keep them in solution for up to 30 minutes at room temperature.

After recovery, transfer the slices to a 35 by 10 millimeters Petri dish with five millimeters of respiration buffer. Using a stainless steel biopsy punch create a circular piece of tissue in the desired area of the sliced brain by gently pressing down the punch while keeping the slice in the buffer. Then remove the rest of the tissue, lift the punch away and remove the circular piece of tissue into the buffer.

Next, cut the very end of a one milliliter pipette tip to make a hole with a one-point-five to two-point-zero millimeter diameter and use it to hold and transfer the punched slice to the top of the capture screen. Suction one piece of punched brain tissue and carefully place the tissue onto the mesh side of the capture screen, a circular piece of plastic with the mesh attached to one side. Using a paper tissue gently dry the capture screen and remove the moisture, which allows the tissue to become sticky and attached to the center of the mesh.

Next, hold the capture screen slice-side down with tweezers and place it into one of the wells of the incubating eyelet plate. Then incubate the eyelet plate at 37 degrees Celsius in an incubator for at least 30 minutes to allow temperature and pH equilibration before running the assay. Dilute the desired compounds and modified artificial cerebral spinal fluid without BSA to the final stock concentration of the working concentration for ports A to D, respectively.

Gently preload 75 microliters of the diluted compounds into the appropriate injection ports of the sensor cartridge by placing the tips halfway into the injection ports at a 45 degree angle with the tip against the wall of the injection port, as complete insertion may cause compound leakage through the port. Afterward, withdraw the tips from the ports carefully without creating air bubbles and do not tap any portion of the cartridge to avoid alleviating air bubbles. Then visually inspect the injection ports for even loading ensuring all liquid is in the port and no residual drops are present on top of the cartridge.

After placing the sensor cartridge onto the utility plate put it into an incubator for 30 minutes to allow it to heat up to 37 degrees Celsius while handling carefully by only holding onto the utility plate and moving as little as possible. First load the assay template in the software and then press the green start button. Then load the sensor cartridge on the utility plate into the instrument tray, ensuring that the plate sits correctly and is flat, loading the drug-filled sensor cartridge into the analyzer for calibration.

Afterward, follow the instructions on the screen in order to calibrate. And equilibrate the sensors. Once the equilibration step is done, remove the calibration plate and replace it with the eyelet plate containing the mesh and tissue slices.

Then measure the oxygen consumption rate in each well of the plate, using the assay protocols as described in the manuscript. Following, analyze the oxygen consumption rate measurement data and the coupling efficiency data. Oxygen consumption rates for different thicknesses and punch sizes of slices in the control group showed stable basal respiration over the whole measurement and were proportional to the volume of the slice.

Furthermore, oxygen consumption rates were relatively stable for five hours with less than 10%rundown. The mitochondrial coupling efficiency was compared and the slice at the 150 micrometer thickness and a 1.5 millimeter punch size showed the highest coupling efficiency. The oxygen consumption rates were measured for young and old groups of Pink1 knockout and their age-matched wild-type mice.

The basal oxygen consumption rate was similar in both the knockout and wild-type groups for young mice. However it decreased for the knockout mice in the old group. However, the mitochondrial dysfunction in the knockout mice was observed for the young age group, indicated by the decreased coupling efficiency caused by the knockout of Pink1.

The critical steps in this protocol includes preparing brain slices, transferring them to the top of capture screen, placing slides into wells and the keeping them attached to the capture screen during the measurements.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Oxygen Consumption RateAcute Striatal SlicesAdult MiceSeahorse XF AnalyzerMitochondrial FunctionCellular EnergeticsParkinson's DiseaseHuntington's DiseaseExtracellular Flux Assay KitRespiration BufferArtificial Cerebrospinal FluidBrain DissectionVibratome Sectioning

Related Videos

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code