Tonometer Use

Tonometer use is the measurement of intraocular pressure (IOP), an important assessment in eye care and pharmacology because abnormal pressure can indicate impaired aqueous humor regulation or treatment effects. In applanation tonometry, the instrument determines the force required to flatten a defined area of the cornea, while other tonometers estimate pressure through indentation or rebound. Pharmacologists use tonometry to evaluate how drugs alter aqueous humor production, drainage, or both, supporting research on glaucoma therapies and ocular drug safety. Standardized measurements also help monitor responses over time and compare the pressure-lowering effects of experimental or established treatments.

Tonometer Use - Related Videos

Education

JoVE Science Education - Clinical Skills

Lateral Canthotomy and Inferior Cantholysis

0 Views •

2023

Source: James W Bonz, MD, Emergency Medicine, Yale School of Medicine, New Haven, Connecticut, USA Lateral canthotomy is a potentially eyesight-saving procedure when performed emergently for an orbital compartment syndrome. An orbital compartment syndrome results from a buildup of pressure behind the eye; as pressure mounts, both the optic nerve and its vascular supply are compressed, rapidly leading to nerve damage and blindness if the pressure is not quickly relieved. The medial and lateral...

Research

JoVE EoE - Neuropathology

Induction of Elevated Intraocular Pressure in a Rat Model

0 Views •

2025

Source: Lani-Louzada, R., et al., Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents. J. Vis. Exp. (2022)This video demonstrates the induction and monitoring of elevated intraocular pressure (IOP) in a rat model. The process involves cauterizing the limbal blood vessels, resulting in vessel occlusion and elevated IOP. The rat is then allowed to recover, and IOP is regularly monitored in both the experimental and control eyes for comparison.

Three-dimensional Angiogenesis Assay System using Co-culture Spheroids Formed by Endothelial Colony Forming Cells and Mesenchymal Stem Cells

0 Views •

Cited by 14 •

2019

Three-dimensional co-culture spheroid angiogenesis assay system is designed to mimic the physiologic angiogenesis. Co-culture spheroids are formed by two human vascular cell precursors, ECFCs and MSCs, and embedded in collagen gel. The new system is effective for evaluating angiogenic modulators, and provides more relevant information to the in vivo study.

A Laser-induced Mouse Model of Chronic Ocular Hypertension to Characterize Visual Defects

0 Views •

Cited by 26 •

2013

Chronic ocular hypertension is induced using laser photocoagulation of the trabecular meshwork in mouse eyes. The intraocular pressure (IOP) is elevated for several months after laser treatment. The decrease of visual acuity and contrast sensitivity of experimental animals are monitored using the optomotor test.

Research

JoVE Journal - Medicine
Free Sample

A Magnetic Microbead Occlusion Model to Induce Ocular Hypertension-Dependent Glaucoma in Mice

0 Views •

Cited by 71 •

2016

Here, we present a protocol to induce ocular hypertension in the murine eye that results in the loss of retinal ganglion cells as observed in glaucoma. Magnetic microbeads are injected into the anterior chamber and attracted to the iridocorneal angle using a magnet to block the outflow of aqueous humour.

View All Results

FAQs

Related Topics