Overview
In this video, we describe the surgical procedure to generate a rabbit calvarial model to evaluate the bone regeneration capacities of bone sample substitution materials of interest.
Protocol
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Surgery
- Site preparation
- Place the rabbit on a heated pad (39 °C) covered by a mattress pad (to avoid burns) on the surgery table. Shave the scalp.
- Apply a lubricating gel on the eyes to avoid irritation and dryness. Disinfect the site by scrubbing the skin with povidone iodine (10%). Then drape the rabbit with a sterile surgical drape and cut out an access area for the skull.
- Disinfect the surgical site with povidone iodine (10%) for a second time. Apply a lubricating gel on the eyes to avoid irritation and dryness.
- Prepare a draped table (sterile drape) on which to place the complete surgical tray.
- Surgical site opening
- Anesthetize locally with a subcutaneous (SC) injection of lidocaine 2% (1 mL) on the skull.
- Incise through the skin (with a scalpel) along the calvarial sagittal line, from the orbits to the external occipital protuberance (~4 cm in length). Ensure that the periosteum is incised.
- Gently elevate the periosteum (with a periosteal elevator) on both side of the incision. Rinse the site with sterile saline.
- Cylinder placement
- Locate the median and coronal sutures on the skull (Figure 2A, B). Note that these anatomical lines form a cross. The cylinders will be placed in each of the quadrants defined by the cross, ensuring that the edge of the cylinder is not over the suture (Figure 2C).
- Place the first cylinder on the left upper quadrant (left frontal bone), and try to lay the device flat. Fix in the position with strong hand pressure and screw a micro-screw, until resistance is felt. Ensure that the screw head is flush with the surface of the cylinder tab.
- Repeat the same procedure on the other tab to fix the cylinder tightly onto the skull. Ensure that the cylinder is hermetically fixed to the bone.
- Repeat the procedure on the right upper quarter (right frontal bone), left lower quarter (left parietal bone) and right lower quarter (right parietal bone).
- Bone drilling of 5 intramedullary holes within the area circumscribed by the cylinders (Figure 1)
- Drill an intramedullary hole under saline irrigation (0.8 mm in diameter, ~1 mm in depth) with a round bur on the bone, in the center of the area circumscribed by the cylinder. Ensure that bleeding appears.
- Drill two more intramedullary holes along the axis passing through the two tab screws, at the inner edges of the cylinder. Along the perpendicular axe, drill two more intramedullary holes at the inner edges of the cylinder. Ensure that bleeding appears.
- Repeat the operation within the three other cylinders.
- Filling cylinders with material samples and capping (Figure 3)
- Prepare the desired bone substitute material according to manufacturer instructions or material specifications.
- Fill the first cylinder to the brim with the material sample and close the cylinder by fitting the cap. Repeat the process in the 3 other cylinders.
- Surgical site closure
- Close the skin above the cylinders with an intermittent non-resorbable suture.
- Apply a sprayable dressing onto the wound.
2. Post-surgical treatment
- Stop analgesia and anesthesia (propofol and fentanyl perfusion arrest) supply and check the recovery of autonomous breathing.
- Stop the ventilation once the animal has recovered autonomous breathing. Maintain the animal under pure oxygen before complete awakening.
- Inject buprenorphine hydrochloride SC (0.02 mg/kg, 0.03 mg/mL, 0.67 mL/kg) and repeat the injection every 6 h for 3 days as post-surgical analgesia.
- Transfer the animal into its usual housing with water and complete feeding.
Subscription Required. Please recommend JoVE to your librarian.
Representative Results
Figure 1: Specifications of PEEK cylinders. Two holes (0.8 mm in diameter) were drilled on the lateral stabilizing tabs for screwing. The positions of the 5 intramedullary holes (0.8 mm in diameter) to be drilled on the skull within the area delimited by the cylinder are marked using red circles.
Figure 2: Representative image of the rabbit skull and placement of the cylinders. Pictures showing the median and coronal sutures on the rabbit skull delineating the left-right parietal and frontal bones (A,B). Placement of the cylinders on both side of the sutures (C). Scale bars = 5 mm.
Figure 3: Representative image of cylinders fixed, filled and caped. Picture showing four cylinders fixed onto the skull of a rabbit with titanium screws. Within the area delimited by each cylinder, 5 intramedullary holes (0.8 mm in diameter, ~1 mm in depth) were drilled under irrigation with a round bur to allow bone cell migration. Cylinders were filled with different bone substitute samples (calibrated volumes) before capping (one closed cylinder is shown only). Scale bar = 5 mm.
Subscription Required. Please recommend JoVE to your librarian.
Materials
Name | Company | Catalog Number | Comments |
Drugs | |||
Fentanyl | Bischel | For analgesia | |
Ketalar 50mg/ml | Pfizer | Ketamine for anesthesia | |
Lidohex | Bichsel | Lubricating gel for the eyes | |
Opsite | Smith and Nephew | 66004978 | Sprayable dressing |
Povidone iodine 10%, Betadine | Mundipharma | anti-infective agent | |
Propofol 2% | Braun | 3538710 | For anesthesia |
Rapidocain 2% | sintetica | Local anesthesia | |
Rompun 2% | Bayer | Xylazin for anesthesia | |
Sevoflurane 5% | Abbvie | For anesthesia | |
Equipment | |||
Fresenius Vial pilot C | Imexmed | Infusion pump | |
Heated pad | Harvard Apparatus | ||
Suction dominant 50 | Medela | ||
Suction tubing Optimus | Promedical | 80342.2 | |
Surgical motor | Schick dental | Qube | Drilling of intramedullary holes |
Ventilation | Maquet Servo1 | ||
Material | |||
Cylinders and caps | Boutyplast | Customized | composition: PEEK (poly ether ether ketone) |
Manual self-retaining shaft | GlobalD | ACT1K | |
Mobile handle for self-retaining shaft | GlobalD | MTM | |
Self- drilling screws | GlobalD | VA1.2KL4 | cross-drive screws composed by Titanium grade5, ISO 5832-3 |
Surgical tray | |||
Endotracheal tube Shiley diameter 2,5mm | Covidien | 86233 | For intubation |
Endotracheal tube Shiley diameter 4,9mm | Covidien | 107-35G | For intubation |
Ethicon prolene 4-0 | Ehticon | 8581H | Non-resorbable suture |
Forceps | Marcel Blanc | BD027R | 145 mm |
Intubation catheter | Cook medical | Guide for intubation | |
Round surgical burs | Patterson | 78000 | 0.8 mm in diameter, Drilling of intramedullary holes |
Scalpel | Swann-Morton | n°10 and n°15 | |
Scissors | Marcel Blanc | 657 | 180 mm |
Syringes Omnifix | Braun | 4616057V | 5ml, 10ml and 50ml |
Venflon G22 | Braun | 42690985-01 | Vasofix safety for the ear iv line |