0 weergaven • 3:23 min • April 30th, 2023
- Prepare tapered injection needles by pulling thin-walled glass capillaries using a needle puller. Hold a needle under a microscope and break the tip, making sure that the opening is just large enough to pierce the adult fly cuticle without wounding it more than necessary. Measure the injection volume by loading your needle with a sterile dye and salt buffer solution and then ejecting it onto a drop of mineral oil on a stage micrometer. Use the scale on the micrometer to measure the diameter of the ejected droplet, which can be used to calculate the volume dispensed, and calibrate your injector settings accordingly.
Load the needle with your injection solution and mount it onto an injection nozzle. Anesthetize your flies with CO2 and arrange them on a CO2 fly pad that will keep them anesthetized. Once the flies are in the correct orientation for your experiment, proceed with the injections. In the example protocol, we will inject adult flies with fluorescein-labeled particles for in vivo imaging.
- After pulling thin-walled glass capillaries with a needle puller, use a micrometer to hold the needle under a microscope and use number five fine-point stainless steel tweezers to break the tip to a 100 micrometer tip diameter. To measure the volume of liquid that will be injected into each fly, load a capillary needle with sterile 5% food coloring in PBS and expel the liquid onto a drop of mineral oil on a 0.01 millimeter stage micrometer.
Dispense 10 microliters of 1.6 milligrams per milliliter particles onto a small square of parafilm and pull the liquid into the needle. Mount the needle into the injector nozzle and line the anesthetized flies along their designated area on the fly pad, ventral side up, with the heads oriented toward the front of the pad. Place the vials in corresponding areas on the bench and inject the flies at the upper corner of the abdomen with five 100 milliseconds pumps of liquid to deliver about 10 nanoliters of particles total. Transfer each fly into the appropriate vial as it is injected, noting the time on the vial.
Next, load a new needle with 0.4% Trypan Blue solution and set the pneumatic injector to 'gated' to allow a constant flow of air to push the liquid out of the needle. 30 minutes after the initial injection, inject each fly abdomen with Trypan Blue until the abdomens are full and distended. Mount the flies on microscope slides with electrical tape ventral side down, pushing the wings to the side of the fly to secure them to the tape. Then gently push the head into the tape to ensure that the fly will not move.
Dit artikel beschrijft een protocol voor het injecteren van volwassen vliegen met fluoresceïne-gelabelde deeltjes voor in vivo beeldvorming. De methode omvat het voorbereiden van taps toelopende injectienaalden en het anesthetiseren van de vliegen om nauwkeurige injecties te vergemakkelijken.
Precieze toediening van verbindingen in modelorganismen maakt mechanische risicoreductie van therapeutische targets mogelijk en ondersteunt de ontwikkeling van assays in een vroeg stadium. Deze methode biedt een schaalbare benadering voor het introduceren van gelabelde verbindingen of biologische stoffen in volwassen Drosophila, wat fenotypische screening en workflows voor targetvalidatie faciliteert. Door het injectievolume te standaardiseren en weefselbeschadiging te minimaliseren, wordt de reproduceerbaarheid in discovery biology-pipelines verbeterd.
Deze methode past binnen het ontdekkingscontinuüm van hypothesetesten van targets tot lead-identificatie, in het bijzonder wanneer de lokalisatie van verbindingen of targetmodulatie in vivo gevisualiseerd moet worden.
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Gerelateerde video's
0 Bekeken
Laatst bijgewerkt: 29 augustus 2026