-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

PL

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

pl_PL

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Cancer Research
Mysi model guza w komorze grzbietowego fałdu skórnego do połączonej mikroskopii przyżyciowej i ob...
Mysi model guza w komorze grzbietowego fałdu skórnego do połączonej mikroskopii przyżyciowej i ob...
JoVE Journal
Cancer Research
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Cancer Research
A Dorsal Skinfold Window Chamber Tumor Mouse Model for Combined Intravital Microscopy and Magnetic Resonance Imaging in Translational Cancer Research

Mysi model guza w komorze grzbietowego fałdu skórnego do połączonej mikroskopii przyżyciowej i obrazowania metodą rezonansu magnetycznego w translacyjnych badaniach nad rakiem

Full Text
2,592 Views
10:25 min
April 12, 2024

DOI: 10.3791/66383-v

W. Jeffrey Zabel*1, Nader Allam*1, Hector Alejandro Contreras Sanchez1, Warren Foltz2,3, Costel Flueraru4, Edward Taylor2,3, Alex Vitkin1,2,3

1Department of Medical Biophysics,University of Toronto, 2Radiation Medicine Program,Princess Margaret Cancer Centre, 3Department of Radiation Oncology,University of Toronto, 4Advanced Electronic and Photonics Research Center,National Research Council of Canada

AI Banner

Please note that some of the translations on this page are AI generated. Click here for the English version.

Overview

This study presents a dorsal window chamber mouse model that integrates intravital microscopy with MRI for enhanced imaging capabilities. The approach aims to improve the clinical translation of findings from preclinical studies by correlating high-resolution imaging with clinically relevant modalities.

Key Study Components

Area of Science

  • Neuroscience
  • Imaging Techniques
  • Oncology

Background

  • Intravital microscopy provides high-resolution images but has limited tissue penetration.
  • MRI offers greater depth penetration but lacks spatial resolution.
  • Combining these modalities can enhance understanding of tumor microenvironments.
  • Perfusion-sensitive imaging methods reveal microvasculature's role in tumor response.

Purpose of Study

  • To correlate intravital microscopy with MRI for better clinical translation.
  • To explore how microvasculature impacts tumor response to therapies.
  • To utilize advanced imaging techniques for longitudinal studies.

Methods Used

  • Dorsal window chamber mouse model for intravital imaging.
  • Magnetic resonance imaging for depth penetration.
  • Optical coherence tomography for biophotonics imaging.
  • AI image analysis for identifying predictive biomarkers.

Main Results

  • Successful integration of intravital microscopy with MRI.
  • Revealed insights into tumor microvasculature and treatment response.
  • Demonstrated the utility of 3D printing in custom tool manufacturing.
  • AI analysis facilitated the identification of novel biomarkers.

Conclusions

  • The combined imaging approach enhances the understanding of tumor biology.
  • It may streamline the translation of preclinical findings to clinical applications.
  • Future studies can build on this model to explore other therapeutic strategies.

Frequently Asked Questions

What is the significance of using a dorsal window chamber model?
The dorsal window chamber model allows for real-time imaging of tumor microenvironments, facilitating the study of biological processes in vivo.
How does this study improve clinical translation?
By correlating high-resolution intravital microscopy with MRI, the study aims to provide a clearer understanding of tumor responses, aiding in clinical applications.
What imaging techniques were combined in this study?
The study combined intravital microscopy with magnetic resonance imaging (MRI) and optical coherence tomography.
What role does AI play in this research?
AI image analysis is used to identify novel radiotherapy predictive biomarkers, enhancing the study's findings.
What are the implications of this research for cancer treatment?
The findings may lead to improved strategies for predicting tumor responses to therapies, ultimately enhancing treatment outcomes.
How does 3D printing contribute to this study?
3D printing aids in the cost-effective manufacturing of custom tools necessary for conducting longitudinal studies.

Tłumaczenie wyników mikroskopii przyżyciowej jest utrudnione ze względu na jego płytką głębokość penetracji w tkanki. W tym miejscu opisujemy mysi model komory z oknem grzbietowym, który umożliwia jednoczesną rejestrację mikroskopii przyżyciowej i klinicznie stosowanych metod obrazowania (np. CT, MRI) w celu bezpośredniej korelacji przestrzennej, potencjalnie usprawniając kliniczne tłumaczenie wyników mikroskopii przyżyciowej.

Przedkliniczne obrazowanie przyżyciowe ma bardzo wysoką rozdzielczość, ale ograniczoną głębokość penetracji w tkance, co czyni je bardzo dobrym do przedklinicznych badań obrazowych. Z drugiej strony, rezonans magnetyczny ma znacznie większe zastosowanie kliniczne i ma większą penetrację głębokości, ale bardzo niską rozdzielczość przestrzenną. Celem tego badania jest skorelowanie tych dwóch modalności ze sobą, aby lepiej przełożyć nasze wyniki z przedklinicznej mikroskopii przyżyciowej na praktykę kliniczną za pomocą rezonansu magnetycznego.

Metody obrazowania wrażliwe na perfuzję w rezonansie magnetycznym i biofotonice, w tym nasza optyczna koherentna tomografia i system geograficzny, ujawniają, w jaki sposób mikrokrążenie wpływa na odpowiedź guza na hipofrakcjonowane drukowanie radiotherapy. 3D pomaga również w opłacalnej produkcji niestandardowych narzędzi, ułatwiając badania podłużne. Wreszcie, analiza obrazu w oparciu o sztuczną inteligencję ułatwia identyfikację nowych biomarkerów predykcyjnych radioterapii.

View the full transcript and gain access to thousands of scientific videos

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Komora okienna grzbietowego fałdu skórnego mysi model guza mikroskopia przyżyciowa rezonans magnetyczny translacyjne badania nad rakiem obrazowanie przedkliniczne korelacja MRI obrazowanie wrażliwe na perfuzję biofotonika optyczna tomografia koherentna biomarkery radioterapii druk 3D badania podłużne korejestracja stereotaktyczna radioterapia ciała mikrokrążenie guza

Related Videos

Obrazowanie przyżyciowe oparte na oknie czaszkowym w modelu mysim: technika obrazowania służąca do badania zachowania wstępnie wstrzykniętych komórek rakowych w mózgu modelu mysiego

03:07

Obrazowanie przyżyciowe oparte na oknie czaszkowym w modelu mysim: technika obrazowania służąca do badania zachowania wstępnie wstrzykniętych komórek rakowych w mózgu modelu mysiego

Related Videos

3K Views

Obrazowanie na żywo odpowiedzi na leki w mikrośrodowisku guza w mysich modelach raka piersi

08:26

Obrazowanie na żywo odpowiedzi na leki w mikrośrodowisku guza w mysich modelach raka piersi

Related Videos

25.5K Views

Nowatorska technika obrazowania in vivo o wysokiej rozdzielczości do badania dynamicznej odpowiedzi struktur wewnątrzczaszkowych na wzrost guza i terapie

12:09

Nowatorska technika obrazowania in vivo o wysokiej rozdzielczości do badania dynamicznej odpowiedzi struktur wewnątrzczaszkowych na wzrost guza i terapie

Related Videos

12K Views

Mikroskopia przyżyciowa naczyń krwionośnych związanych z nowotworem przy użyciu zaawansowanych komór okiennych grzbietowych fałdów skórnych na transgenicznych myszach fluorescencyjnych

08:52

Mikroskopia przyżyciowa naczyń krwionośnych związanych z nowotworem przy użyciu zaawansowanych komór okiennych grzbietowych fałdów skórnych na transgenicznych myszach fluorescencyjnych

Related Videos

14.8K Views

Długotrwała mikroskopia przyżyciowa o wysokiej rozdzielczości w płucach z okienkiem obrazowania stabilizowanym podciśnieniowo

07:19

Długotrwała mikroskopia przyżyciowa o wysokiej rozdzielczości w płucach z okienkiem obrazowania stabilizowanym podciśnieniowo

Related Videos

14K Views

Hiperspolaryzowana spektroskopia i obrazowanie metabolicznego rezonansu magnetycznego 13C

11:43

Hiperspolaryzowana spektroskopia i obrazowanie metabolicznego rezonansu magnetycznego 13C

Related Videos

11.1K Views

In vivo (in vivo) Ocena EPR pH, pO2, stanu redoks oraz stężeń fosforanów i glutationu w mikrośrodowisku guza

10:46

In vivo (in vivo) Ocena EPR pH, pO2, stanu redoks oraz stężeń fosforanów i glutationu w mikrośrodowisku guza

Related Videos

8.8K Views

Podłużne obrazowanie przyżyciowe zachowania komórek guza mózgu w odpowiedzi na inwazyjną biopsję chirurgiczną

09:17

Podłużne obrazowanie przyżyciowe zachowania komórek guza mózgu w odpowiedzi na inwazyjną biopsję chirurgiczną

Related Videos

7.9K Views

Nowatorski, modulowany fibroblastami zrębu model sferoidalny 3D guza do badania interakcji guz-zręb i odkrywania leków

07:20

Nowatorski, modulowany fibroblastami zrębu model sferoidalny 3D guza do badania interakcji guz-zręb i odkrywania leków

Related Videos

10.5K Views

Modelowanie przerzutów do mózgu poprzez iniekcję wewnątrzczaszkową i rezonans magnetyczny

06:44

Modelowanie przerzutów do mózgu poprzez iniekcję wewnątrzczaszkową i rezonans magnetyczny

Related Videos

8.2K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code