Optical Mapping of Langendorff-perfused Rat Hearts

20.7K views

⸱

DOI:

10.3791/1138

⸱

August 11th, 2009

 ,  , 

In This Article

Summary

This article describes a high temporal and spatial resolution technique to optically image action potential movement on the surface of Langendorff-perfused rat hearts using a potentiometric dye (di-8-ANEPPS).

Abstract

Optical mapping of the cardiac surface with voltage-sensitive fluorescent dyes has become an important tool to investigate electrical excitation in experimental models that range in scale from cell cultures to whole-organs[1, 2]. Using state-of-the-art optical imaging systems, generation and propagation of action potentials during normal cardiac rhythm or throughout initiation and maintenance of arrhythmias can be visualized almost instantly[1]. The latest commercially-available systems can provide information at exceedingly high spatiotemporal resolutions and were based on custom-built equipment initially developed to overcome the obstacles imposed by more conventional electrophysiological methods[1]. Advancements in high-resolution and high-speed complementary metal-oxide-semiconductor (CMOS) cameras and intensely-bright, light-emitting diodes (LEDs) as well as voltage-sensitive dyes, optics, and filters have begun to make electrical signal acquisition practical for cardiovascular cell biologists who are more accustomed to working with microscopes. Although the newest generation of CMOS cameras can acquire 10,000 frames per second on a 16,384 pixel array, depending on the type of sample preparation, long-established fluorescence acquisition technologies such as photodiode arrays, laser scanning systems, and cooled charged-coupled device (CCD) cameras still have some distinct advantages with respect to dynamic range, signal-to-noise ratio, and quantum efficiency[1, 3]. In the present study, Lewis rat hearts were perfused ex vivo with a crystalloid perfusate (Krebs-Henseleit solution) at 37°C on a modified Langendorff apparatus. After a 20 minute stabilization period, the hearts were intermittently perfused with 11 mMol/L 2,3-butanedione monoxime to eliminate contraction-associated motion during image acquisition. For optical mapping, we loaded hearts with the fast-response potentiometric probe di-8-ANEPPS[4] (5 μMol/L) and briefly illuminated the preparation with 475±15 nm excitation light. During a typical 2 second period of illumination, >605 nm light emitted from the cardiac preparation was imaged with a high-speed CMOS camera connected to a horizontal macroscope. For this demonstration, hearts were paced at 300 beats per minute with a coaxial electrode connected to an isolated electrical stimulation unit. Simultaneous bipolar electrographic recordings were acquired and analyzed along with the voltage signals using readily-available software. In this manner, action potentials on the surface of Langendorff-perfused rat hearts can be visualized and registered with electrographic signals.

Protocol

Part 1: Prepare solutions and the isolated perfused heart system

  1. On the morning of the experiment, 4.0 L of Krebs-Henseleit solution is prepared as previously described[5, 6].
  2. 11 mMol/L 2,3-butanedione monoxime (BDM) is dissolved in 1.0 L of Krebs-Henseleit solution decanted from the perfusate prepared in step 1.1.
  3. An additional 150 mL of Krebs-Henseleit is removed from the perfusate prepared in step 1.1 and mixed with 5 Mol/L di-8-ANEPPS (diluted from a 10 mMol/L stock dissolved in dimethyl sulfoxide (DMSO)).
  4. These 3 solutions are transferred to water-jacketed glass reservoirs (Radnoti) where they are pre-warmed to 41....

Access restricted. Please log in or start a trial to view this content.

Discussion

Removal of the heart from anesthetized rats must be performed rapidly to avoid myocardial ischemia. If ischemia or insufficient coronary perfusion occurs, the heart will likely develop arrhythmias and may become infarcted. Additionally, these hearts will show insufficient fluorescence emission for informative recordings and subsequent analyses. Before loading the dye, myocardial cells need to be adequately perfused with Krebs-Henseleit solution to establish and maintain a physiologic electrolyte milieu for the stability .......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Experiments on animals were performed in accordance with the guidelines and regulations set forth by the Institutional Animal Care and Use Committee at Children's Hospital Boston.

Acknowledgements

This work is supported by research grants from the National Institutes of Health (HL068915; HL088206) and contributions to the Cardiac Conduction Fund at Children's Hospital Boston.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
CardioCMOS-SM128fEquipmentRedShirtImaging, LLC
CardioPlex SoftwareEquipmentRedShirtImaging, LLC
LUXEON LED Light Source 460-490 nm EquipmentLumileds Lighting, US, LLC, San Jose, CA 95131 USALXHL-PB02
ECG Amplifier Type 689 Hugo Sachs ElektronikEquipmentHarvard Apparatus730149
Dichroic Mirror 505 nmEquipmentSemrockFF505-SDi01-25x36
Emission Filter 605 nm Long PassEquipmentSciMedia
THT SidewaysEquipmentSciMedia25 BM-8
Mini Ball Joint HolderEquipmentHarvard ApparatusBS4 73-0177
Small Stimulation Electrode SetEquipmentHarvard ApparatusBS4 73-0160
BM-6 Benchtop Vibration Isolation PlatformEquipmentTechnology Inc., Inglewood, CA 9030125 BM-6
Monopolar ECG ElectrodeEquipmentHarvard ApparatusBS4 73-0200
Roller Pump SCI 400EquipmentWatson-Marlow Pumps Group401U/D1
Roller Pump MasterFlex Easy Load IIEquipmentCole-ParmerModel 77201-60
Tubing Marprene #14EquipmentWatson-Marlow Pumps Group902.0016.016
MasterFlex TubingEquipmentPharMed, Westlake, OH 44145 USA06485-25
S48 Square Pulse StimulatorEquipmentGrass TechnologiesModel S48
SIU5 RF TRANSFORMER ISOLATION UNITEquipmentGrass TechnologiesModel SIU5
5 Liter Water Jacketed ReservoirEquipmentRadnoti Glass Technology Inc.120142-5
2 Liter Water Jacketed ReservoirEquipmentRadnoti Glass Technology Inc.120142-2
0.5 Liter Water Jacketed ReservoirEquipmentRadnoti Glass Technology Inc.120142-0
0.25 Liter Water Jacketed ReservoirEquipmentRadnoti Glass Technology Inc.120142-025
10 ml Heating CoilEquipmentRadnoti Glass Technology Inc.158822
Compliance Bubble TrapEquipmentRadnoti Glass Technology Inc.130149
Luer Disconnect CannulaEquipmentHarvard Apparatus72-1444
3-Way stopcock, FLL to MLT, No Port CoversEquipmentHarvard ApparatusBS4 72-2630
Thermocouple ThermometerEquipmentCole-ParmerWU-91100-40
Ultra Fine IT-Series Flexible Microprobe EquipmentPhysiTemp Instruments Inc., Clifton, NJ 07013 USAIT-24P
Oscilloscope Tektronix TDS 1002EquipmentTektronix, Inc.TDS 1002B
2,3-Butanedione monoxime ReagentSigma-AldrichB0753
Ketamine HClReagentHospira Inc.RL-0065
XylazineReagentLloyd, Inc.LB15705A
E-TOXA-CLEAN®ReagentSigma-AldrichE9029
Di-8-ANEPPSReagentInvitrogenD-3167

References

  1. Efimov, I. R., Nikolski, V. P., Salama, G. Optical imaging of the heart. Circ Res. 95 (1), 21-33 (2004).
  2. Hucker, W. J. Images in cardiovascular medicine. Optical mapping of the human atrioventricular junction. Circulation. 117 (11), 1474-147 (2008).
  3. Entcheva, E., Bi....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Langendorff PerfusionCardiac Surface ImagingVoltage-sensitive DyesHigh-speed CMOS CameraAction Potential VisualizationElectrophysiological RecordingsElectrical Activation MappingFluorescent Dye Loading