A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Quantifying Immune Cell Infiltration in Uropathogenic E. coli-Infected Mouse Bladder Tissue using Flow Cytometry

893 views

July 8th, 2025

In This Article

Abstract

Source: Zychlinsky Scharff, A. et al., Urinary Tract Infection in a Small Animal Model: Transurethral Catheterization of Male and Female Mice. J. Vis. Exp. (2017)

In this video, we demonstrate a flow-cytometry-based technique to quantify CD45+ immune cells in Escherichia coli-infected mouse bladder to measure immune cell infiltration.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Flow Cytometric Analysis of Bladder Tissue

  1. Prepare digestion buffer containing collagenase at 34 units/mL and DNase at 100 µg/mL, in PBS. Keep on ice. Prepare one 15 ml conical tube per animal to be analyzed and aliquot 1 ml digestion buffer per tube.
  2. At predetermined time points, sacrifice mice using approved standard operating procedures (e.g., cervical dislocation or carbon dioxide overdose). Moisten the abdomen thoroughly ....

Access restricted. Please log in or start a trial to view this content.

Results

Flow cytometry dot plots and graphs; CD45+ immune cells; male vs female; data analysis results.
Figure 1: Immune Cell Infiltration is Increased in Female Mice in Response to UTI. Six- to eight-week-old female and male C57Bl/6 mice were instilled or not with 107 CFU of UPEC. Representative dot plots depict total bladder cells.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
SyringesB Braun9166017V
Thumb (Adson) forcepsFine Science Tools11006-12
5 mL tubes, polypropyleneFalcon352063
Tissue Ruptor disposable probesQiagen990890
15 mL flip cap tubesThermo Scientific362694
DNAseInvitrogen18047019
100 µM MACS SmartStrainersMiltenyi130-098-463Compatible with 15 mL tubes, preferred
100 µm cell strainersFalcon352360Compatible with 50 mL tubes, if MACS Smart Strainers are not available
96 well plateFalcon353077
Fc blockBD Pharmingen553142Anti-CD16/CD32
Anti-mouse CD45 antibodyBD Biosciences561487Many different fluorescent conjugation options are available
5 mL tubes polystyrene with filter capFalcon352235
Hand held homogenizerQiagen9001272TissueRuptor
Flow cytometerBD BiosciencesN/AFortessa SORP
Flow cytometry softwareBD BiosciencesN/ADiva

Tags

E. coli InfectionCD45 AntibodyTissue DigestionSingle-Cell SuspensionFc BlockingCell StrainerFluorescence Detection