| Collagenase Type Ia | Sigma | C2674 | Dilute in 10ml PBS to get a final concentration of 10mg/ml. Store at -20°C in 1ml aliquots. |
|---|
| Dulbecco's PBS | Sigma | D8662 | With calcium and magnesium chloride. Keep sterile and store at room temperature. |
|---|
| 1X Medium M199 | Gibco | 31150-022 | Warm in 37 °C water bath before use. |
|---|
| Gentamicin sulphate | Sigma | G1397 | Store at 4°C. Add to M199 500ml bottle. |
|---|
| Human epidermal growth factor | Sigma | E9644 | Store at -20°C in 10µl aliquots. |
|---|
| Fetal calf serum (FCS) | Sigma | F9665 | FCS must be batch tested to ensure the growth and viability of isolated EC. Heat inactivate at 56°C. Store in 10ml aliquots at -20°C. |
|---|
| Amphotericin B | Gibco | 15290-026 | Potent and becomes toxic within a week so fresh complete HUVEC medium must be made up every week. Store at -20°C in 1ml aliquots. |
|---|
| Hydrocortisone | Sigma | H0135 | Stock is in ethanol. Store at -20°C in 10µl aliquots. |
|---|
| Collagenase Type II | Sigma | C6885 | Dilute stock in PBS to a final concentration of 100mg/ml. Store at -20°C in 100µl aliquots. |
|---|
| Hyaluronidase | Sigma | H3631 | Dilute stock in PBS to a final concentration of 20,000U/ml. Store at -20°C in 100µl aliquots. |
|---|
| 100µm cell strainer for 50ml centifuge tube | Scientific Lab Supplies (SLS) | 352360 | Other commercially available cell strainers (e.g. Greiner bio-one) can also be used. |
|---|
| DMEM low glucose | Biosera | LM-D1102/500 | Warm in 37 °C water bath before use. |
|---|
| Penicillin/Streptomycin mix | Sigma | P4333 | Store at -20°C in 1ml aliquots. |
|---|
| 25cm2 tissue culture flask | SLS | 353109 | |
|---|
| 75cm2 tissue culture flask | SLS | 353136 | |
|---|
| Bone marrow mesenchymal stem cells vial | Lonza | PT-2501 | Store in liquid nitrogen upon arrival. Cells are at passage 2 upon arrival but are designated passage 0. Exapand to passage 3 and store in liquid nitrogen for later use. |
|---|
| Mesenchymal stem cell growth medium (MSCGM) | Lonza | PT-3001 | Warm in 37 °C water bath before use. For Cell Tracker Green staining use medium without FCS. |
|---|
| EDTA (0.02%) solution | Sigma | E8008 | Store at 4°C. Warm in 37°C water bath before use. |
|---|
| Trypsin solution | Sigma | T4424 | Store at -20°C in 2ml aliquots. Thaw at room temperature and use immediately. |
|---|
| Cryovials | Greiner bio-one | 2019-02 | Keep on ice before adding before adding cell suspension. |
|---|
| Mr. Frosty Freezing Container | Nalgene | 5100-0001 | Store at room temperature. When adding cryovials with cells store at -80°C for 24h before transfrring cells to liquid nitrogen. |
|---|
| Cell tracker green dye | Life technologies | C2925 | Store in 5µl aliquots at -20°C. Dilute in 5ml prewarmed (at 37°C) MSCGM. |
|---|
| Cell counting chambers | Nexcelom | SD-100 | Alternatively a haemocytometer can be used. |
|---|
| Cellometer auto T4 cell counter | Nexcelom | Auto T4-203-0238 | |
|---|
| Tumor necrosis factor α (TNFα) | R&D Systems | 210-TA-100 | Dilute stock in PBS to a final concentration of 100,000U/ml. Store at -80°C in 10µl aliquots. |
|---|
| 6-well, 0.4µm PET Transwell filters | SLS | 353090 | |
|---|
| K2-EDTA in 10ml tubes | Sarstedt | | Store at room temperature. |
|---|
| Histopaque 1119 | Sigma | 11191 | Store at 4°C. Warm to room temperature before use. |
|---|
| Histopaque 1077 | Sigma | 10771 | Store at 4°C. Warm to room temperature before use. |
|---|
| 10ml round bottomed tube | Appleton Woods | SC211 142 AS | |
|---|
| 7.5% BSA Fraction V solution | Life technologies | 15260-037 | Store at 4°C. |
|---|
| 20ml Plastipak syringes | BD falcon | 300613 | |
|---|
| 5ml Plastipak syringes | BD falcon | 302187 | |
|---|
| 2ml Plastipak syringes | BD falcon | 300185 | |
|---|
| 3M hypo-allergenic surgical tape 9m x 2.5cm | Micropore | 1530-1 | Use to secure the syringe tap onto the wall of the perspex chamber. |
|---|
| Silicon rubber tubing, internal diameter/external diameter (ID/OD) of 1/3mm (thin tubing) | Fisher Scientific | FB68854 | Cut silicon tubing to the appropriate size. All tubing leading directly to the electronic microvalve must be thin. |
|---|
| Silicon rubber tubing ID/OD of 2/4mm (thick tubing) | Fisher Scientific | FB68855 | |
|---|
| Portex Blue Line Manometer tubing | Smiths | 200/495/200 | Tubing leading to the syringe pump. |
|---|
| 3-way stopcock | BOC Ohmeda AB | | |
|---|
| Glass 50ml syringe for pump | Popper Micromate | 550962 | Must be primed prior to use by removing any air bubbles. |
|---|
| Glass coverslip | Raymond A Lamb | | 26x76mm coverslips made to order. Lot number 2440980. |
|---|
| Parafilm gasket | American National Can Company | | Cut a 26x76mm piece of parafilm using an aluminium template and cut a 20x4mm slot into it using a scalpel 10a. Gasket thickness is approximately 133µm. |
|---|
| Two perspex parallel plates | Wolfson Applied Technology Laboratory | | Specially designed chamber consisting of parallel plates held together by 8 screws. The lower plate has a viewing slot cut out in the middle and a shallow recess milled to allow space for the coverslip, filter and gasket. The upper perspex plate has an inlet and outlet hole positioned over the flow channel. |
|---|
| Electronic 3-way microvalve with min. dead space | Lee Products Ltd. | LFYA1226032H | Electronically connected to a 12 volt DC power supply. |
|---|
| Syringe pump for infusion/withdrawal (PHD2000) | Harvard Apparatus | 70-2001 | Set the diameter to 29mm and refill (flow) rate. |
|---|
| L-shaped connector | Labhut | LE876 | To attach to the inlet and outlet ports onto the Ibidi microslide channel. |
|---|
| Video camera | Qimaging | 01-QIC-F-M-12-C | Connected to a computer which enables digitall videos to be recorded. |
|---|
| Image-Pro Plus 7.0 | Media Cybernetics | 41N70000-61592 | For data analysis. Manually tag cells displaying the different behaviors. Track cells for analysis of rolling and migration velocities. |
|---|