Monitoring Electrical Signals from the Afferent Neurons in an Immobilized Zebrafish Larva

969 views

July 8th, 2025

In This Article

Abstract

Source: Lunsford, E. T., et al. Activity of Posterior Lateral Line Afferent Neurons during Swimming in Zebrafish. J. Vis. Exp. (2021).

This video demonstrates the recording of electrical signals from the afferent neurons in a paralyzed zebrafish larva by positioning a micropipette near the lateral line ganglion and forming a loose seal for signal capture. The extracellular solution maintains neuronal viability during this process.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation of materials for electrophysiological recordings

  1. Make a silicone elastomer-bottomed recording dish.
    1. Dispense a thin layer of self-mixing silicone elastomer components (e.g., Sylgard) into a cover glass-bottomed tissue culture dish until it levels with the rim of a shallow well. Approximately 0.5 mL is sufficient.
    2. Cover and cure the dish for a minimum of 48 h at room temperature.
  2. Make dissection pins.
      ....

Access restricted. Please log in or start a trial to view this content.

Results

Electrophysiology setup: Micropipettes, microscope, fish neuron diagram; data graph; neural activity.
Figure 1: Simultaneous electrophysiological recording of posterior lateral line afferent neuron and ventral motor root activity. (A). Example of a loose-patch afferent (i) and ventral motor root (ii) r.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
100 mL beakerPYREX1000Resceptacle for etchant
10x water immersion objectiveOlympusUMPLFLN10xWLow magnification for positioning larvae and recording electrode
40x water immersion objectiveOlympusLUMPLFLN40XWHigher magnification for position electrode tip and establishing patch-clamp
BNC coaxial cablesThorLabs2249-C-12Connecting amplifier and digitizer channels; require 4
Borosilicate glass capillaries w/ filamentWarner InstrumentsG150F-3Inner diameter: 0.86, outer diameter: 1.50; capillary glass used to form recording electrodes
ComputerN/AN/AAny computer should work
DC Power SupplyTenma72-420Used for electrically etching dissection pins
Electrophysiology digitizerAxon Instruments, Molecular DevicesAxon DigiData 1440AEnables acquisition of patch-clamp data
FilamentSutter Instrument CompanyFB255B2.5 mm box filament used in micropipette puller
Fine forcepsFine Science ToolsDumont #5 (0.05 x 0.02 mm) Item No. 11295-10Used to manipulate larvae and insert pins
Fixed stage DIC microscopeOlympusBX51WIMicroscope used to visualize and establish patch-clamp recordings
Flexible, tapered pipette tipFisher Scientific02-707-169Flexible tips enable insertion into recording electrode to dispense extracellular solution at the tip
FluoroDishWorld Precision Instruments Inc.FD3510-100Cover glass bottomed dish recording dish
KimWipeKimTech34155Task wipe used for wicking away excess fluid from larvae
Kwik-GardWorld Precision Instruments Inc.710172Self-mixing sylgard elastomer
Microelectrode amplifierAxon Instruments, Molecular DevicesMultiClamp 700BPatch clamp amplifier for dual channel recordings
MicroforgeNarishigeMF-830 microforgeTo polish recording electrode
Micromanipulator control unitSiskiyouMC1000-eR/T4-axis dial coordinator for controlling micromanipulator
Micropipette pullerSutter Instrument CompanyFlaming/Brown P-97For pulling capillary glass into recording electrodes
Microscope control unitSiskiyouMC1000ePositions the microscope around the fixed stage and preparation
Motorized micromanipulatorSiskiyouMX7600Positions the headstage and attached recording electrode for patch-clamp recording
MultiClamp CommanderMolecular Devices2.2.2Downloadable from Axon MultiClamp 700B Commander download page
Optical air tableNewport CorporationVH3036W-OPTBreadboard isolation table to float microscope and minimize vibrations during recordings
pCLAMPMolecular Devices10.7.0Downloadable from Axon pCLAMP 10 Electrophysiology Data Acquisition & Analysis Software Download page
Petri-dishFalcon35-3001Used to immerse larvae in paralytic
Pipette holderMolecular Devices1-HL-UHold recording electrode and connect to the headstage
Pneumatic transducerFluke Biomedical InstrumentsDPM1BFor controlling recording electrode internal pressure
Potassium hydroxideSigma-Aldrich221473-25GEtchant for etching dissection pins
Silicone tubingTygon14-169-1ATubing to connect pneumatic transducer to pipette holder
StereomicroscopeCarl ZeissStemi 2000-CUsed to visualize pin tips and during preparation of larvae
Straight edge razor bladeCanopusorder from amazon.comCuts the tungsten wire while making dissection pins
syringeBecton Dickinson Compoany309602Filled with extracellular solution to inject into recording electrodes
Transfer pipetteSigma-AldrichZ135003-500EASingle use, non-sterile pipette for transfering larvae
Tricaine methanesulfonateSyndel12854Pharmaceutical aneasthetic used to euthanize larvae with high dosage.
Tungsten wireWorld Precision Instruments Inc.7155000.002 inch, 50.8 μm diameter; used to make dissection pins
Vacuum filtration unitSigma-AldrichSCGVU11RESingle use, sterile, vacuum filtration units used to sterilize extracellular solution used for electrophysiology electrode ringer
Voltage-clamp current-clamp headstageMolecular DevicesCV-7BSupplied with MultiClamp 700B amplifier used as left and right headstages
α-bungarotoxinThermoFisherB1601For immobilizing the larvae prior to recording