Note: C. difficile is a human and animal pathogen that can cause gastrointestinal disease. Experiments involving C. difficile must be performed with appropriate biosafety precautions (BSL-2).
1. Anaerobic Chamber Use and Maintenance
C. difficile is a strict anaerobe and is extremely sensitive to even low concentrations of oxygen in the atmosphere. Therefore, a controlled, anaerobic environment is needed for its successful manipulation. The use of an anaerobic chamber (Figure 1A) provides the most stable environment and the ideal conditions for effective cultivation of C. difficile and other anaerobic bacteria14. Here, an atmosphere containing a gas mixture (5% CO2, 10% H2, 85% N2) can be stably maintained.
To introduce any items into the chamber without significant oxygen contamination, an airlock must be used (Figure 1B). This device functions as a gas interchange and works automatically, semi-manually or manually. The airlock has two doors: one providing access to the outside of the airlock and the other providing access to the interior of the anaerobic chamber. Depending on the model, the airlock may have an additional door, which can offer access to an adjoining anaerobic chamber, thus saving the cost of a separate airlock. Unless actively moving items in or out of the chamber, both doors should remain closed at all times to avoid oxygen contamination. The airlock possesses an on/off switch on the front and a panel containing four buttons. The gas lines and vacuum pump hose are connected in the rear of the airlock, near the panel where the switches for full manual operation of the unit are located. It is recommended that two purge cycles, using nitrogen gas (N2), are used before filling the interchange with gas mix (5% CO2, 10% H2, 85% N2) to reduce the amount of oxygen introduced into the chamber. It is also important to never leave either door open for longer than the amount time required to move items in and out of the interchange and to carefully plan experiments to reduce the frequency of moving items in and out of the chamber. The different operating procedures for vinyl anaerobic chambers are outlined below. Before following these protocols, ensure that these are compatible with the manufacturer’s instructions provided with the chamber.
- Automatic Mode
This is a programmable and customizable mode and is performed entirely by the airlock. To program the airlock, refer to the manufacturer’s instructions. A recommended program for typical entry into the chamber involves two purge cycles using nitrogen gas followed by refilling the airlock with a gas mix that closely matches the atmosphere maintained within the chamber. During each vacuum cycle, the standard factory procedures suggest pulling a vacuum to 20 inHg and purging to 1 inHg.
- Ensure that the inner airlock door is fully closed.
- Open the outer airlock door.
- Place items into airlock and close the outer airlock door. If introducing liquids, unscrew the caps halfway to ensure efficient gas exchange. Sealed packages and containers should be opened prior to beginning the cycle; refraining from doing so may warp and damage plasticware and containers. To maintain sterility, open the packages enough to only allow efficient gas exchange.
- Press the Start button.
- Wait until the airlock has cycled through the program and the display reads "Anaerobic."
- Open inner airlock door.
- Move items into the chamber.
- Close inner door.
- Semi-manual Mode
This mode may be used when moving items in or out of the chamber and is necessary when cycling the gas within the chamber is required.
- Ensure that the inner airlock door is fully closed.
- Open the outer airlock door.
- Place items into airlock and close the outer airlock door. If introducing liquids, unscrew the caps halfway to ensure efficient gas exchange. Sealed packages, such as inoculating loops and 96-well plates, must be opened prior to beginning the cycle.
- Press Menu.
- Press Start. The airlock will display the function of each button and will not respond until this is completed:
- Up arrow: activates the vacuum pump.
- Down arrow: initiates the nitrogen (purge) gas flow.
- Start: initiates the gas mix flow.
- Menu: return to the default display.
- Press "Up," removing gas from the airlock, until the display reads 20 inHg.
- Press "Down," filling the airlock with nitrogen, until the display reads less than 1 inHg. Do not overshoot, as this will create positive pressure within the airlock, which may affect its integrity.
- Repeat steps 6 and 7 to perform an additional purge cycle.
- Press "Up" until the display reads 20 inHg.
- Press "Start," filling the interchange with gas mix, until the display reads less than 1 inHg.
- Open inner airlock door.
- Move items into the chamber.
- Close inner door.
- Manual Mode
This mode may be used whenever the automatic or semi-manual modes are not working or there is no power to the airlock. This mode does not function when the airlock is on; therefore, it is difficult to determine the pressure within the airlock. Because the vacuum pull and gas purge times is dependent upon vacuum and gas flow rates, respectively, the use of a pressure gauge within the interchange is required to monitor the pressure and reduce the risk of personal injury and damage to the airlock.
- Ensure that the inner airlock door is fully closed.
- Open the outer airlock door.
- Place items, including the pressure gauge, into airlock and close the outer airlock door. If introducing liquids, unscrew the caps halfway to ensure efficient gas exchange. Sealed packages, such as inoculating loops and 96-well plates, must be opened prior to beginning the cycle.
- Locate the three switches on the back of the airlock labeled "Manual Control Switches." These are individually labeled as:
- To Vacuum
- Nitrogen
- Gas Mix
- Flip the To Vacuum toggle switch until the pressure gauge reads approximately 20 inHg.
- Flip the Nitrogen toggle switch until the pressure gauge reads approximately 1 inHg.
- Flip the To Vacuum toggle switch until the pressure gauge reads approximately 20 inHg.
- Flip the Nitrogen toggle switch until the pressure gauge reads approximately 1 inHg.
- Flip the To Vacuum toggle switch until the pressure gauge reads approximately 20 inHg.
- Flip the Gas Mix toggle switch until the pressure gauge reads approximately 1 inHg.
- Open inner airlock door.
- Move items into the chamber.
- Close inner door.
2. Culturing, Enumerating and Storing C. difficile from Stool Samples
This procedure is designed to recover C. difficile from fecal samples containing spores and subsequently maintain isolated colonies as vegetative cells or spores in long-term storage as glycerol stocks. Alternatively, this procedure may be used to enumerate the number of C. difficile present in stool samples (e.g. from animal studies). To selectively and differentially enrich for C. difficile, taurocholate-cefoxitin-cycloserine-fructose agar (TCCFA) is used to inhibit growth of normal fecal flora15-16. Cycloserine is bacteriostatic for Gram-negative bacteria, while cefoxitin more broadly inhibits growth of both Gram-negative and -positive bacteria, with the exception of C. difficile and most enter cocci strains. A pH indicator, neutral red, can be included in the medium, as the fermentation of fructose will result in a decrease in pH and a subsequent color change from red/orange to yellow. To efficiently recover spores of C. difficile as vegetative bacteria, the bile salt sodium taurocholate is used to induce germination17-18. Because C. difficile forms spores, alcohol or heat treatment of samples may be used to reduce or eliminate vegetative cells, limiting the growth of contaminating flora, which may increase the efficiency of C. difficile recovery19. As mentioned above, it is critical to pre-reduce all plates for at least 1-2 hr in the anaerobic chamber prior to use to ensure the removal of residual oxygen. Air drying the plates prior to use in the chamber can reduce condensation. Liquid medium may need up to 24 hr to reduce depending on the volume and the surface-to-air ratio of the container used.
Before beginning, the following items should be placed into the anaerobic chamber:
- Stool sample
- Sterile swabs
- Sterile inoculating loops
- 1x PBS (see Materials)
- TCCFA plates (see Materials)
- BHIS (Brain Heart Infusion medium with yeast extract) plates and broth (see Materials)
- 50% glycerol (sterilized)
- 10% L-cysteine (sterilized)
- Cryogenic storage vials
*Alternatively, isolated colonies can be spread onto BHIS agar plates, and subsequently scraped off and resuspended in BHIS liquid medium with 15% glycerol for long-term storage at -80°C. **It is important to note that Gram-staining is not an effective strategy to identify C. difficile directly from stool samples23; C. difficile must first be isolated from the other flora present in the stool.
- Resuspend the stool sample in 1x PBS (this may be performed in aerobic conditions), and ensure that the stool sample is fully resuspended in 1x PBS by vortexing. If enumerating C. difficile from the stool, weigh the stool sample prior to the addition of 1x PBS.
- Make serial dilutions of the resuspended stool sample in 1x PBS for appropriate isolation or enumeration of colony forming units (CFU) per gram of stool.
- Using aseptic technique, apply 100 μl of each serial dilution to TCCFA plates.
- Using a series of sterile inoculating loops, streak the applied culture for isolated colonies or evenly spread the applied culture on the surface of the TCCFA plate for enumeration of colonies.
- Incubate the plate anaerobically for 48 hr at 37 °C. It is possible to detect and identify C. difficile colonies within 24 hr based on the flat, irregular, ground-glass appearance of the colonies15, although more accurate identification and enumeration is achieved after 48 hr.
- Using sterile inoculating loops, subculture any colonies that appear to be C. difficile onto pre-reduced BHIS agar plates, supplemented with 0.03% L-cysteine20. Pick an individual colony, and streak onto the plate in quadrants, using a new sterile inoculating loop for each quadrant, to obtain isolated colonies. Alternatively, count the C. difficile colonies of each dilution (this may be performed in aerobic conditions), and calculate the number of colony forming units per gram of stool sample.
- Confirm C. difficile identification via Gram-staining. After Gram-staining, C. difficile will appear as purple rods and some cells may contain terminal endospores. Polymerase chain reaction (PCR) identification of the genes that encode toxin B may provide further confirmation of toxigenic strains of C. difficile21 while multilocus sequence typing (MLST) is successful for identification and accurate typing of unknown and nontoxigenic strains of C. difficile22.
- To maintain a stock of C. difficile at -80 °C, pick an individual, isolated colony from the BHIS agar plate using a sterile inoculating loop and resuspend the colony in 10 ml of pre-reduced BHIS liquid medium supplemented with 0.03% L-cysteine.*
- Incubate overnight anaerobically at 37 °C, or until the culture becomes turbid.
- Add 333 μl of 50% glycerol and 666 μl of the C. difficile culture to a 1.8 ml cryogenic tube to create a 15% glycerol stock of the isolated strain.
- Tightly cap the cryogenic tube, mix well and immediately remove the stock from the anaerobic chamber and place in a -80 °C freezer for long-term storage.
3. Culturing C. difficile from Frozen Glycerol Stocks
This procedure provides for recovery of C. difficile from glycerol stocks stored at -80 °C. Because repeated freeze-thaw cycles may kill vegetative cells, it is important to keep the glycerol stocks frozen at all times. We do not recommend the use of dry ice for transferring strains in and out of the chamber as the evaporation of dry ice can change the environment within the chamber. Instead, we recommend using frozen cooling racks to keep glycerol stocks frozen during transport. For various selective and differential purposes, three media are commonly used for culturing C. difficile. TCCFA, as discussed above, is selective for C. difficile and contains sodium taurocholate, a germinant. Brain heart infusion supplemented with yeast extract (BHIS) is a commonly used, enriched, non-selective medium which allows for the growth of a wide variety of organisms (Figure 2A)24. Frequently, L-cysteine is added to BHIS as a reducing agent20. Finally, the addition of blood to the medium (Figure 2B) allows for more efficient sporulation than on TCCFA and provides for detection of the unique greenish or chartreuse fluorescence exhibited by C. difficile under long-wave ultraviolet (UV) light15 (Figure 2C). When culturing C. difficile from spore stocks, it is critical to remember that sodium taurocholate must be added to the medium to ensure germination.
Before beginning, the following items should be placed into the anaerobic chamber:
- Frozen glycerol stock (in cooling rack)
- Sterile inoculating loops
- TCCFA or BHIS plates (see Materials)
- BHIS broth (see Materials)
- 50% glycerol (sterilized)
- Cryogenic storage vials
- Place the frozen glycerol stock of C. difficile in a cooling rack that has been stored at -80 °C prior to use to prevent thawing.
- Bring the frozen glycerol stock on dry ice into the anaerobic chamber.
- Using aseptic technique and a sterile inoculating loop, place a small amount of the stock onto the plate and streak across one quadrant of the plate.
- Rotate the plate 90° and, using a new sterile inoculating loop, continue to streak across the second quadrant.
- Repeat for the third and fourth quadrants to ensure the isolation of individual colonies.
- Immediately remove the frozen glycerol stock from the anaerobic chamber and return to the -80 °C.
- Incubate the plate anaerobically overnight at 37 °C. Individual isolated colonies should be observed after overnight growth.
4. Purifying Spores from C. difficile
As sporulation is required for survival in oxygen-rich environments and for efficient transmission of disease8, the preparation of spore stocks is often necessary for downstream applications, not limited to microscopy and animals studies. It is important to note that enumerating spores requires repetition to ensure reproducibility of counts. Pipetting up and down several times between dilutions also reduces loss since spores adhere to plastic well.
Sporulation of C. difficile is not as rapid or homogeneous as other sporogenic species. To optimize spore production and recovery, either sporulation medium (SMC)17,25 or 70:30 medium26 is recommended. Other media commonly used are BHIS, which requires 4-5 days of growth before efficient sporulation is seen27, and Clospore, a liquid medium that produces high titers of spores (107 - 108 spores per milliliter) after 72 hr of growth. Other protocols use ice-cold water rather than 1x PBS20; however, the use of an isotonic solution can reduce spores from sticking to each other and plastic surfaces. Alternatively, some investigators further purify their spores using a sucrose gradient to fully remove vegetative cells and debris29.
Before beginning, the following items should be placed into the anaerobic chamber:
- Sterile inoculating loops
- BHIS, SMC and/or 70:30 plates (see Materials)
- BHIS broth (see Materials)
- 1x PBS, filter-sterilized (see Materials)
- Culture strains from frozen glycerol stock onto pre-reduced BHIS plates and incubate anaerobically overnight at 37 °C.
- Restreak onto several pre-reduced SMC or 70:30 plates and incubate anaerobically at 37 °C for 24-48 hours. Spore formation can be followed via phase contrast microscopy. Spores will appear phase bright while vegetative and mother cells will appear phase dark. *As an alternative, spores can be purified from 70:30 liquid medium after 24-48 hours, which yields 105-106 spores per milliliter, depending on the strain used.
- Using a sterile inoculating loop, scrape plates and resuspend the cells in 10 ml sterile 1x PBS.
- Discard plates and remove spore suspension from the anaerobic chamber. Pellet the cells at 3,000 x g for 15 minutes. Wash the cells twice in 1x PBS, fully resuspending the cell pellet each time.
- Incubate overnight at 4 °C to aid in lysis of vegetative and mother cells.
- Incubate at 70 °C for 20 min to kill any residual vegetative cells.
- To determine colony forming units (CFU) per milliliter, serially dilute each spore preparation in 1x PBS and plate on BHIS + 0.1% sodium taurocholate. Incubate plates for a minimum of 24 hr before enumerating colonies.
- Spores can be stored in 1x PBS at either room temperature or 4°C for long-term storage. If stored at 4 °C, it may be useful to reheat the spore preparation at 55 °C for 15 min to restore efficient germination.