Intracellular recording is a powerful technique used to determine how a single cell may respond to a given stimulus. In vision research, intracellular recording has historically been a common technique used to study sensitivities of individual photoreceptor cells to different light stimuli that is still being used today. However, there remains a dearth of detailed methodology in the literature for researchers wishing to replicate intracellular recording experiments in the eye. Here we present the insect as a model for examining eye physiology more generally. Insect photoreceptor cells are located near the surface of the eye and are therefore easy to reach, and many of the mechanisms involved in vision are conserved across animal phyla. We describe the basic procedure for in vivo intracellular recording of photoreceptor cells in the eye of a butterfly, with the goal of making this technique more accessible to researchers with little prior experience in electrophysiology. We introduce the basic equipment needed, how to prepare a live butterfly for recording, how to insert a glass microelectrode into a single cell, and finally the recording procedure itself. We also explain the basic analysis of raw response data for determining spectral sensitivity of individual cell types. Although our protocol focuses on determining spectral sensitivity, other stimuli (e.g., polarized light) and variations of the method are applicable to this setup.
The electrical properties of cells such as neurons are observed by measuring ion flow across cell membranes as a change in voltage or current. A variety of electrophysiological techniques have been developed to measure bioelectric events in cells. Neurons found in the eyes of animals are accessible and their circuitry is often less complex than in the brain, making these cells good candidates for electrophysiological study. Common applications of electrophysiology in the eye include electroretinography (ERG)1,2 and microelectrode intracellular recording. ERG involves placing an electrode in or on the eye of an animal, applying a light stimulus, and measurin....
Access restricted. Please log in or start a trial to view this content.
All animals were treated as humanely as possible. Insects were shipped as pupae from Costa Rica Entomological Supply, Costa Rica.
1. Heliconius Pupae Care
Access restricted. Please log in or start a trial to view this content.
For many elements of the recording setup, a written description does not provide enough detail. Figure 1 is a schematic of the components involved in the complete recording setup. In Figure 2, spectra are plotted for white light and each interference filter to give a sense of why a correction factor is needed and what is needed to calculate this correction. Figure 3 shows photos and a diagram of the Cardan arm that is used for these experiments. Figure 4.......
Access restricted. Please log in or start a trial to view this content.
Intracellular recording can be a difficult technique to master due to the many technical steps involved. For successful experiments several important points must be considered. First, it is important to have a properly vibrationally-isolated table on which the experiment is performed. Many researchers use air tables, which completely separate the tabletop from the base, giving superior vibration isolation. Our setup involves a thick marble table with a sandbox on top, into which is placed the micromanipulator/electrode h.......
Access restricted. Please log in or start a trial to view this content.
The authors declare that they have no competing financial interests.
We thank the late Rudy Limburg for fabricating the cardan arm perimeter, Kimberly Jamison, Matthew McHenry, and Raju Metherate for lending us equipment, and Almut Kelber and Kentaro Arikawa, for encouragement. This work was supported by a National Science Foundation (NSF) Graduate Research Fellowship to KJM and NSF grant IOS-1257627 to A.D.B.
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| Butterfly pupae | Several local species available, need USDA permits for shipping. Carolina Bio Supply has several insect species that may be ordered within the U.S. without the need for additional permits | ||
| Large plastic cylinder | Any chamber that remains humidified will work | ||
| Insect pins, size 2 | BioQuip | 1208B2 | |
| 100% Desert Mesquite Honey | Trader Joe's | Any honey or sucrose solution will work | |
| Xenon Arc Lamp | Oriel Instruments | 66003 | Oriel is now a part of Newport Corporation |
| Universal Power Supply | Oriel Instruments | 68805 | Oriel is now a part of Newport Corporation |
| Optical Track | Oriel Instruments | 11190 | Oriel is now a part of Newport Corporation |
| Rail Carrier, Large (2x) | Oriel Instruments | 11641 | Oriel is now a part of Newport Corporation |
| Rail Carrier, Small (4x) | Oriel Instruments | 11647 | Oriel is now a part of Newport Corporation |
| Thread Adaptor, 8-32 Male to 1/4-20 Male, pack of 10 | Newport Corporation | TA-8Q20-10 | |
| Optical Mounting Post, 1.0 in., 0.5 in. Dia. Stainless, 8-32 & 1/4-20 (5x) | Newport Corporation | SP-1 | |
| No Slip Optical Post Holder, 2 in., 0.5 in. Diameter Posts, 1/4-20 (5x) | Newport Corporation | VPH-2 | |
| Fixed lens mount, 50.8 mm | Newport Corporation | LH-2 | |
| Fixed lens mount, 25.4 mm | Newport Corporation | LH-1 | |
| Condenser lens assembly | Newport Corporation | 60006 | |
| Convex silica lens, 50.8 mm | Newport Corporation | SPX055 | |
| Six Position Filter Wheel, x2 | Newport Corporation | FW1X6 | |
| Filter Wheel Mount Hub | Newport Corporation | FWM | |
| Concave silica lens, 25.4 mm | Newport Corporation | SPC034 | |
| Collimator holder | Newport Corporation | 77612 | |
| Collimating beam probe | Newport Corporation | 77644 | |
| Ferrule Converter, SMA Termination to 11 mm Standard Ferrule | Newport Corporation | 77670 | This adapter allows the fiber optic to fit into the collimator holder |
| 600 μm diameter UV-vis fiber obtic cable | Oriel Instruments | 78367 | Oriel is now a part of Newport Corporation |
| Shutter with drive unit | Uniblitz | 100-2B | |
| UV Fused Silica Metallic ND Filter, 0.1 OD | Newport | FRQ-ND01 | |
| UV Fused Silica Metallic ND Filter, 0.3 OD | Newport | FRQ-ND03 | |
| UV Fused Silica Metallic ND Filter, 0.5 OD | Newport | FRQ-ND05 | |
| UV Fused Silica Metallic ND Filter, 1.0 OD | Newport | FRQ-ND10 | |
| UV Fused Silica Metallic ND Filter, 2.0 OD | Newport | FRQ-ND30 | |
| UV Fused Silica Metallic ND Filter, 3.0 OD | Newport | FRQ-ND50 | |
| LS-1-Cal lamp | Ocean Optics | LS-1-Cal | |
| Spectrometer | Ocean Optics | USB-2000 | |
| SpectraSuite Software | Ocean Optics | ||
| Interference bandpass filter, 300 nm | Edmund Optics | 67749 | |
| Interference bandpass filter, 310 nm | Edmund Optics | 67752 | |
| Interference bandpass filter, 320 nm | Edmund Optics | 67754 | |
| Interference bandpass filter, 330 nm | Edmund Optics | 67756 | |
| Interference bandpass filter, 340 nm | Edmund Optics | 65614 | |
| Interference bandpass filter, 350 nm | Edmund Optics | 67757 | |
| Interference bandpass filter, 360 nm | Edmund Optics | 67760 | |
| Interference bandpass filter, 370 nm | Edmund Optics | 67761 | |
| Interference bandpass filter, 380 nm | Edmund Optics | 67762 | |
| Interference bandpass filter, 390 nm | Edmund Optics | 67763 | |
| Interference bandpass filter, 400 nm | Edmund Optics | 65732 | |
| Interference bandpass filter, 410 nm | Edmund Optics | 65619 | |
| Interference bandpass filter, 420 nm | Edmund Optics | 65621 | |
| Interference bandpass filter, 430 nm | Edmund Optics | 65622 | |
| Interference bandpass filter, 440 nm | Edmund Optics | 67764 | |
| Interference bandpass filter, 450 nm | Edmund Optics | 65625 | |
| Interference bandpass filter, 460 nm | Edmund Optics | 67765 | |
| Interference bandpass filter, 470 nm | Edmund Optics | 65629 | |
| Interference bandpass filter, 480 nm | Edmund Optics | 65630 | |
| Interference bandpass filter, 492 nm | Edmund Optics | 65633 | |
| Interference bandpass filter, 500 nm | Edmund Optics | 65634 | |
| Interference bandpass filter, 510 nm | Edmund Optics | 65637 | |
| Interference bandpass filter, 520 nm | Edmund Optics | 65639 | |
| Interference bandpass filter, 532 nm | Edmund Optics | 65640 | |
| Interference bandpass filter, 540 nm | Edmund Optics | 65642 | |
| Interference bandpass filter, 550 nm | Edmund Optics | 65644 | |
| Interference bandpass filter, 560 nm | Edmund Optics | 67766 | |
| Interference bandpass filter, 570 nm | Edmund Optics | 67767 | |
| Interference bandpass filter, 580 nm | Edmund Optics | 65646 | |
| Interference bandpass filter, 589 nm | Edmund Optics | 65647 | |
| Interference bandpass filter, 600 nm | Edmund Optics | 65648 | |
| Interference bandpass filter, 610 nm | Edmund Optics | 65649 | |
| Interference bandpass filter, 620 nm | Edmund Optics | 65650 | |
| Interference bandpass filter, 632 nm | Edmund Optics | 65651 | |
| Interference bandpass filter, 640 nm | Edmund Optics | 65653 | |
| Interference bandpass filter, 650 nm | Edmund Optics | 65655 | |
| Interference bandpass filter, 660 nm | Edmund Optics | 67769 | |
| Interference bandpass filter, 671 nm | Edmund Optics | 65657 | |
| Interference bandpass filter, 680 nm | Edmund Optics | 67770 | |
| Interference bandpass filter, 690 nm | Edmund Optics | 65659 | |
| Interference bandpass filter, 700 nm | Edmund Optics | 67771 | |
| Faraday cage | Any metal structure will work that can be grounded and that fits the experimental setup. | ||
| Stereomicroscope, 6X, 12X, 25X, 50X magnification | Wild Heerbrugg | Wild M5 | Any Stereomicroscope will do |
| Microscope stand with swinging arm and heavy base | McBain Instruments | Any heavy base with arm will do | |
| Cardan arm | Custom built, See Figure 4 | ||
| Fiber-lite high intensity illuminator | Dolan-Jenner | MI-150 | For lighting specimen |
| Fiber-lite goose-neck light guide | Dolan-Jenner | EEG 2823 | Any goose-neck light guide will do |
| Marble table | |||
| Raised wooden table | Hole should be cut through this table so that the sandbox can rest on the marble table underneath | ||
| Wooden box filled with sand | custom built, any box with sand | ||
| Manipulator | Carl Zeiss - Jena | ||
| Electrode holder | |||
| Specimen stage | |||
| Alligator clip wires for grounding | |||
| Insulated copper wire | |||
| Silver wire, 0.125 mm diameter | World Precision Instruments | AGW0510 | |
| BNC cables | |||
| Preamplifier with headstage | Dagan Corporation | IX2-700 | |
| Humbug Noise reducer | Quest Scientific | Humbug | |
| Oscilloscope, 30 MHz, 2 CH, Dual Trace, Alt-triggering, without probe | EZ Digital | os-5030 | |
| BNC T-adapter | |||
| Powerlab hardware 2/20 | ADI instruments | ML820 | |
| Labchart software | ADI instruments | Chart 5 | |
| 10 MHz Pulse Generator | BK Precision | 4030 | |
| Glass pipette puller | Sutter Instruments | P-87 | |
| Borosillicate glass capillaries with filament | World Precision Instruments | 1B120F-4 | |
| Potassium chloride, 3 M | |||
| Slotted plastic tube | |||
| Low melting temperature wax | |||
| Soldering Iron | Weller | ||
| Platform with ball-and-socket magnetic base | Hama photo and video | ||
| Double edge carbon steel, breakable razor blade | Electron Microscopy Sciences | 72004 | |
| Vaseline | |||
| Microsoft Excel | Microsoft |
Access restricted. Please log in or start a trial to view this content.