Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model

Published: January 13, 2023 doi: 10.3791/64544

ERRATUM NOTICE

Summary

Presented here is a protocol to use controlled hyperthermia, generated by magnetic resonance-guided high intensity focused ultrasound, to trigger drug release from temperature-sensitive liposomes in a rhabdomyosarcoma mouse model.

Abstract

Magnetic resonance-guided high intensity focused ultrasound (MRgHIFU) is an established method for producing localized hyperthermia. Given the real-time imaging and acoustic energy modulation, this modality enables precise temperature control within a defined area. Many thermal applications are being explored with this noninvasive, nonionizing technology, such as hyperthermia generation, to release drugs from thermosensitive liposomal carriers. These drugs can include chemotherapies such as doxorubicin, for which targeted release is desired due to the dose-limiting systemic side effects, namely cardiotoxicity. Doxorubicin is a mainstay for treating a variety of malignant tumors and is commonly used in relapsed or recurrent rhabdomyosarcoma (RMS). RMS is the most common solid soft tissue extracranial tumor in children and young adults. Despite aggressive, multimodal therapy, RMS survival rates have remained the same for the past 30 years. To explore a solution for addressing this unmet need, an experimental protocol was developed to evaluate the release of thermosensitive liposomal doxorubicin (TLD) in an immunocompetent, syngeneic RMS mouse model using MRgHIFU as the source of hyperthermia for drug release.

Introduction

Rhabdomyosarcoma (RMS) is a skeletal muscle tumor that most commonly occurs in children and young adults1. Localized disease is often treated with multimodal treatment, including chemotherapy, ionizing radiation, and surgery. The use of multi-drug chemotherapy regimens is more prevalent in pediatric patients, with improved outcomes compared to their adult counterparts2; however, despite ongoing research efforts, the 5-year survival rate remains at around 30% in the most aggressive form of the disease3,4. The chemotherapy standard of care is a multidrug regimen that includes vincristine, cyclophosphamide, and actinomycin D. In cases of relapsed or recurrent disease, alternate chemotherapies are used, including standard (free) doxorubicin (FD) and ifosfamide1. While all these chemotherapies have systemic toxicities, the cardiotoxicity of doxorubicin imposes a life-long dose limitation5-7. To increase the amount of the drug delivered to the tumor and to minimize systemic toxicity, alternative formulations have been developed, including liposomal encapsulation. These can be non-thermosensitive doxorubicin, which has been approved for the treatment of breast cancer and hepatocellular carcinoma, or thermosensitive doxorubicin, for which clinical trials are ongoing8,9,10,11,12,13. Alternative methods for delivering liposomal encapsulated drugs such as multi-vesicular liposomes and ligand-targeted liposomes have been evaluated and show promise for the treatment of tumors9. In this study, the addition of heat has multifactorial impacts, including drug release14. The combination of hyperthermia (HT) generated with magnetic resonance-guided high intensity focused ultrasound (MRgHIFU) and thermosensitive liposomal doxorubicin (TLD) is a novel multimodal therapeutic approach for using this toxic yet effective drug to treat RMS, while minimizing dose-limiting toxicity and potentially increasing the immune response to the tumor.

Doxorubicin releases rapidly from TLD at temperatures >39 °C, well above the average human body temperature of 37 °C but not high enough to cause tissue damage or ablation; this starts to occur at 43 °C, but occurs more rapidly as temperatures approach 60 °C15. Various methods have been used to generate HT in vivo, including lasers, microwaves, radiofrequency ablation, and focused ultrasound, many of which are invasive heating methods16. MRgHIFU is a noninvasive, nonionizing heating method that facilitates precise temperature settings within the target tissue in situ. Magnetic resonance (MR) imaging crucially provides real-time imaging, where computer software can be used, to calculate a thermometry measurement of the tissue throughout treatment; subsequently, this data can be used to control the ultrasound therapy in real time to reach and maintain a desired temperature set point17. MRgHIFU has been tested in various tissue types and can be used for a wide range of temperature treatments, from mild HT to ablation, as well as clinically to successfully treat painful bone metastases18. Additionally, HT has been shown to cause tumor cytotoxicity, modulate protein expression, and alter the immune response in the tumor microenvironment19,20,21,22. One study combined mild HT with TLD, followed by ablation with MRgHIFU, in a synergetic R1 rat model23, resulting in necrosis in the tumor core and drug delivery to the periphery. Traditionally, radiotherapy has been used as an adjunct therapy to damage tumor cells and decrease local disease recurrence. However, its use is limited by lifetime dosing and off-target damage1. Thus, HT is unique in that it can cause some of the same effects without the same toxicities or limitations.

Preclinical animal models for RMS include syngeneic immunocompetent models and patient derived xenografts (PDX) in immunocompromised hosts. While the immunocompromised models allow for growth of the human tumors, they lack the appropriate tumor microenvironment and are limited in their ability to study immune response24. FGFR4-activating mutation is a promising marker for poor prognosis and a potential therapeutic target in adult and pediatric RMS1,25. In the syngeneic RMS models developed in the Gladdy lab, the tumors are able to grow in an immunocompetent host, which develops innate and adaptive immune responses to the tumor26. As HT influences the immune response, observation of the change in the murine immune response is a valuable advantage of this tumor model. To test both the tumor response to TLD in comparison to FD, as well as the change in the immune response of the tumor to both chemotherapy and HT, a protocol was developed and employed to treat syngeneic murine RMS tumors in vivo using MRgHIFU and TLD, which is the focus of this study.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

Research was performed in compliance with the animal care committees with approved animal use protocols under a supervising veterinarian at The Centre for Phenogenomics (TCP) and University Health Network (UHN) Animal Resource Centre (ARC) animal research facilities. All procedures, excluding the MRgHIFU, involving the animals were done in a biological safety cabinet (BSC) to minimize animal exposure to external air or susceptible infection.

1. Mouse breeding

NOTE: A total of 65 mice (strain B6.129S2-Trp53tm1Tyj/J) were included in the pilot study (male: n = 23; female: n = 42). Both male and female mice were used at 7-9 weeks of age. Their pups were weaned and genotyped, and the p53 heterozygous mice were used for the experiments.

  1. House two female mice with each male mouse to create breeding cages. Count the ages of their pups from birth (birth = day 0).
  2. At day 10, identify the pups with an ear notch. Collect tail snips for genotyping prior to cell line injection.

2. Mouse genotyping

  1. Extract DNA from the collected 2 mm tail clippings using a commercial DNA extraction kit (see Table of Materials), following the manufacturer's instructions.
  2. Determine the DNA concentration and purity by measuring the absorbance at 260-280 nm on a spectrophotometer (see Table of Materials).
  3. Perform polymerase chain reaction (PCR).
    1. Create a master mix containing a commercial PCR mix (containing Taq polymerase, dNTPS, and MgCl2; see Table of Materials), primer, and dH2O in a 12.5:0.25:10.75 (µL) ratio for the required number of samples. Add 1 µL of DNA sample to each PCR tube and include dH2O, a null sample (homozygous for p53 mutation), a heterozygous sample (heterozygous for p53 mutation), and a wild type (homozygous for normal p53) sample as PCR controls.
    2. Add 24 µL of the master mix to each PCR tube containing DNA. Pipette the solution in each PCR tube up and down to distribute the DNA throughout the master mix.
    3. Place the reaction tubes in a thermal cycler and cycle according to the following specifications: 95 °C for 2 min, 40 cycles of 95 °C for 15 s, 60 °C for 15 s, and 72 °C for 1 min, and then maintain at 4 °C until ready to analyze on the gel.
  4. Analyze the PCR products using agarose gel electrophoresis.
    1. Prepare a 2% gel (50 mL of 1x TAE and 1 g of agarose) by heating the agarose in the TAE and mixing until dissolved. When cooled and still liquid, add 2.5 µL of DNA gel stain to the agarose and mix. Cast the gel in a gel box with a comb. Place the gel in the electrophoretic apparatus (see Table of Materials) and cover with 1x TAE.
    2. Load 10 µL of 1 kB DNA Ladder on the gel. Load 12.5 µL of each sample. Run the gel for 25 min at 135 V.
    3. Image the gel using appropriate settings for the used DNA gel stain on a gel imager (see Table of Materials), according to the manufacturer's instructions.

3. Tumor model preparation (Figure 1)

  1. Grow the M25FV24C cell line (passage 12-15) 1 week prior to the injection date in complete growth media (Dulbecco's Modified Eagle Medium [DMEM] with additives: 10% FBS, 1% Penicillin/Streptomycin, and 2 mM L-alanyl-L-glutamine dipeptide) in a 75 mL flask, at 37 °C and 5% CO2. Once the cells are ~80% confluent, aspirate the media and wash the cells 1x with 5 mL of Dulbecco's phosphate-buffered saline (DPBS).
    NOTE: M25FV24C is a murine cell line engineered to overexpress mutant FGFR4V550E, which is observed in pediatric and adult RMS1,26.
  2. Lift the cells by adding 0.5 mL of 0.25% trypsin solution to the side of the plate and incubating the vessel for 2-3 min at room temperature. Once the cells appear detached, add 2.5 mL of complete growth media at room temperature to inactivate the trypsin. Use a 10 µL sample aliquot to determine the cell concentration of viable cells using a hemocytometer and trypan blue exclusion.
  3. Prepare the correct volume of DPBS-suspended cells for injection and place into a 1.5 mL microcentrifuge tube: volume to centrifuge = (number of mice × number of cells per mouse)/ (concentration of cells), where the number of mice = the mice to be injected + 10 extra mice for error, and the number of cells per mouse = 104.
  4. Centrifuge for 5 min at 153 x g. Resuspend the cell pellet in the appropriate volume (10 µL per mouse × number of mice) of myo-injection buffer (F10 media + 0.5% FBS) and inject the mice within 1 h of preparation of this suspension.

4. Intramuscular cell injection

NOTE: M25FV24C cells are injected into the right hind limb of mice between 4 and 6 weeks of age. Injection at 4 weeks produces a small mouse with a tumor that can be harder to treat as there is less surrounding tissue for HT dispersion; waiting until 6 weeks yields a larger mouse, making it easier to treat the tumor.

  1. Invert the cell suspension several times prior to aspiration to help evenly distribute the cells within the solution. Aspirate 10 µL (104 cells) using a microliter syringe (see Table of Materials). Scruff the mouse; once restrained, access to the caudal thigh muscles can be gained by extending the hind leg. Shave the leg using clippers and wipe with 70% ethanol.
  2. Inject the M25FV24C cell suspension (10 µL, 104 cells) into the right hind limb thigh musculature of a 4-6-week-old mouse using a gas-tight microliter syringe with a 26s G needle.
    NOTE: The needle should be inserted parallel to the femur toward the knee, taking care not to hit the sciatic nerve. Insert only the point of the needle (approximately 2 mm) due to the small muscle mass of the hind limb.
  3. Administer the solution in a steady motion. Remove the needle and ensure bleeding does not occur. Return the mouse to a second cage.
  4. Evaluate the animals daily and monitor their hind limbs for tumor growth through palpation. Euthanize the mice using carbon dioxide if any of the following early end points are encountered: tumor size exceeding 1.5 cm in diameter, tumor ulceration, or systemic signs of illness (piloerection, hunched posture, inactivity, or decreased intake of food or water).

5. Screening MRI scan

  1. Anesthetize the mouse, to a level where there is no movement with paw squeeze, with isoflurane under the following parameters: induce in a chamber with 4% at 1.5 LPM, then transfer to the nose cone on the MRI scanner sled and continue isoflurane maintenance on the nose cone with 1.5%-2% at 0.75 LPM. Attach the respiratory monitor. Use vet ointment on eyes to prevent dryness while under anesthesia.
  2. Image the anesthetized mouse using the MRI scanner (see Table of Materials). On the T2-weighted image (Ax_Screen acquisition, Table 1), take note of in-plane dimensions and the number of axial slices that the tumor appears within. Note the location of the tumor in reference to the femur and lateral surface of the thigh, where the ultrasound wave would enter.
    NOTE: The tumor appears as a hyperintense mass within the muscle that is asymmetric from the opposite side. A good starting tumor size for multiple treatments is 2 mm x 2 mm x 2 mm for either acute or survival studies. If it is much larger, it will only be good for acute studies as the tumor will reach a size end point prior to completing three weekly treatments. Exclusion criteria for HIFU treatment include: wrapped around the femur, too close to the femur, too posterior on the mouse, medial to the femur, too close to the rectum.
  3. Remove the mouse from the scanner and obtain a baseline weight. Shave the mouse from their mid body down to their feet under anesthesia with an electric shaver.
    NOTE: Ideally, shaving is done 1 day prior to treatment, as it allows the mouse to perform grooming which allows the depilatory cream to work more efficiently.
  4. Recover the mouse in the BSC, using a heating pad under one end of the cage. Return the mouse to its cage when it regains sternal recumbency.

6. Experiment: HIFU treatment day animal preparation

  1. To prepare the small bore HIFU (see Table of Materials) system, turn the generator on and fill the transducer with enough deionized water until the membrane is expanded below the transducer, but not so firm that it would compress the mouse. Degas the water in the transducer circuit for 30 min to remove dissolved oxygen from the medium.
  2. Prepare the associated computer system.
    1. Turn on the controlling computer and ensure it is connected via ethernet to the HIFU generator and via USB to the thermal probe display. Start the software and click Home to home the transducer prior to inserting the mouse.
    2. Calibrate the fiberoptic thermal probes: Get the baseline room temperatures and note the temperature change in the MRI room. Note the magnitude of temperature drift for each probe due to the magnetic field strength. Insert the drift tube temperature probe into a gadolinium filled glass tube for temperature calibration during scanning and secure the drift tube with tape.
      NOTE: The baseline room temperature (drift tube) is added manually as a thermometry parameter in the GUI in the software. A region of interest (ROI) is set within the drift tube in the MR image to detect any temperature drift and will automatically correct the thermometry images.
    3. Draw up the drug to be injected into a 1 mL syringe and place it into the automatic delivery pump (see Table of Materials). Prime the line that will connect to the mouse's tail vein catheter until the drug has completely filled the line by pressing the manual delivery button on the automatic delivery pump.
    4. Use a heat lamp to warm the mice in the cages for ~20 min prior to transfer to the anesthetic chamber.
      NOTE: Preheating promotes vasodilation, which will be encountered as soon as the mouse is anesthetized and aids in catheter placement.
  3. Anesthetize the mouse with isoflurane (induction: 4% at 1.5 LPM; maintenance: 1.5%-2% at 0.75 LPM) and transfer to a nose cone. Apply a corneal lubricant to the eyes to prevent damage due to the lack of blink reflex under anesthesia.
  4. Apply depilatory cream to the shaved area, including the entire right hind limb, and follow the manufacturer's instructions for hair removal.
    NOTE: Position the mouse under a heat lamp while in the BSC to help with thermoregulation during hair removal under anesthesia.
  5. After washing off the depilatory cream with warm water, weigh the mouse on a digital scale and record for drug dosing.
  6. Move the mouse to an MRI-compatible nose cone on the MRI sled. Position a heat lamp on the mouse to keep it warm while preparing for the MRI. Place the mouse in the lateral decubitus position with the non-tumor bearing side down and the tumor superior inside a 3D-printed mouse holder on the sled (Supplemental Figure 1 and Figure 2). Ensure proper positioning of the tumor (i.e., in the center of the coil horizontally and vertically, with the height just above the edges of the mouse holder to account for compression by the ultrasound transducer).
    NOTE: If needed, cut a compressed ultrasound gel pad segment to put under the mouse, lining the bottom of the holder, with a thickness to level the tumor to the top of the holder.
  7. Tuck the uninvolved leg away from the tumor leg, either under the mouse or extended with the tumor leg flexed. Ensure the feet are not in the near field or far field of the tumor and ultrasound beam path. Position the heat lamp 15 cm from the tail to warm for catheter insertion into the tail vein.
  8. Insert the esophageal temperature probe.
    1. Thread the esophageal probe through the nose cone and scruff the neck of the mouse. Tilt the mouse nose up to create a line from its mouth straight to its stomach by extending the head. Slide the thermal probe above the tongue about 0.5 cm into the mouse esophagus and replace the nose cone around the mouse's nose. Secure the esophageal probe and nose cone at the top of the sled.
      NOTE: Monitor for signs of respiratory distress immediately after insertion as it can be improperly inserted into the trachea.
  9. Insert the rectal temperature probe.
    NOTE: The rectal and esophageal temperature probes should be within 3 °C of each other.
  10. Place the respiratory monitor with the connecting cable toward the head of the mouse so it does not interfere with the placement of the ultrasound transducer. Secure with tape.
  11. Insert a 27 G butterfly needle tail vein catheter into a lateral tail vein attached to microtubing with 20 µL of dead space and tape securely. After taping, ensure that the catheter is still flushing well.
  12. Use two people to carry the prepared mouse, mouse sled, anesthesia line, respiratory line, tail vein catheter, and thermal probe cords into the MRI scanner, and place into the MRI sled holder.
  13. Have the HIFU software (see Table of Materials) operator move the meniscus of the transducer directly over the tumor by visual inspection for an initial alignment27. Apply eye lubricant or degassed ultrasound gel to the hairless skin above the tumor and couple the HIFU transducer to the tumor area.
  14. Connect the drug delivery line from the automatic pump to the tail vein catheter. Calculate the amount of dead space in the tail vein line and the connecting line. Slide the mouse HIFU sled on MRI rails into the center of the MRI.
  15. Set the amount of drug infusion on the pump, depending on the drug type and concentration and the weight of animal, and add the amount of dead space. Set the pump to a rate of infusion of 200 µL/min.
    NOTE: In this study, FD and TLD were used at a concentration of 2 mg/mL and a dose of 5 mg/kg body weight.
  16. Record the baseline thermal probe temperatures.
  17. Place the air convection warming device (see Table of Materials) on the warmest setting. Point the tube blowing air toward the mouse in the center of the MRI bore and secure with tape. The warming device will later be turned to its lowest setting (32 °C) to prevent overheating of the mouse during sonication.
  18. Acquire the survey MR images (Ax_Loc, Sag_Loc; Table 1) to determine the tumor location for sonication targeting including depth. Adjust the transducer position accordingly using the HIFU software by inserting the desired movement distance as measured on the image and then clicking the arrow direction to move (Figure 3A). Also note the location of the drift tube. Repeat as necessary.
  19. Determine the location of the focal spot of the transducer in the coronal plane by performing a brief 5 s x 50 mV amplitude continuous 'test shot' sonication during the Test_Shot thermometry acquisition (Table 1).
  20. Align the MR survey images with the coronal view of the focal spot within the HIFU software. Review the images for tumor location, relative to bony structure and the rectum, and revise the transducer positioning as deemed necessary.
  21. Repeat the test shot sonication during nine-repetition Therm imaging (Table 1) to confirm whether there is even and accurate heating in the tumor volume with minimal off-target heating. Adjust the slice location, transducer location, and depth of steering, and confirm heating performance with repeat "test shots" as deemed necessary.
  22. Using the HIFU treatment monitoring software, define the ROI for thermometry monitoring within the final heating profile by measuring the distance to move and then altering the grid coordinates in the program. Set an ROI around the drift tube for drift correction. Enter the baseline temperature based on the rectal probe temperature for thermometry measurements. The HIFU system is used to initiate HIFU treatment sonication and for thermometry monitoring.
  23. Open the 20 min hyperthermia treatment specifications in the software and start sonication once the reference MR images are collected and the thermometry begins.
  24. Perform a 20 min treatment (Figure 3B) during Therm imaging (Table 1) using the built-in proportional-integrative-derivative (PID) controller software. Inject the selected drug at 1.5 min, after the temperature in the ROI warms to the desired temperature (40 °C).
  25. Monitor the core temperature throughout treatment. If the rectal temperature is increasing rapidly during treatment, mouse repositioning may be required to avoid rectal warming over the 10 or 20 min treatment duration. Stop the treatment if the rectal temperature increases to >40 °C.

7. Experiment: Mouse model imaging and sonication procedure for acute studies

  1. After completion of the treatment, remove the mouse from the MRI bore, ensuring hemostasis at the tail vein catheter insertion site. Transfer the mouse to the BSC and place on the nose cone for continued anesthesia.
  2. Place the mouse on its back on a blue absorbent pad with its limbs restrained and the heart exposed.
  3. Euthanize the mice through exsanguination via cardiac puncture followed by removal of the heart. Take the blood immediately and centrifuge for plasma separation at 10,621 x g for 10 min.
  4. Perform necropsy and store the organs as required for analysis. Freeze the organs in liquid nitrogen and store at -80 °C for several months or long-term in a liquid nitrogen tank.
  5. Mechanically homogenize the tumor tissue by adding a nine-fold excess (w/w) of deionized water and breaking down the tissue using a bead-beating homogenizer. Extract doxorubicin from 600 µL of homogenized tissue by sequentially adding 75 µL of 300 mg/mL silver nitrate, 75 µL of 10 mM sulfuric acid, and 2.5 mL of 1:1 isopropanol:chloroform. Vortex for 20 min and store at −20 °C overnight.
  6. To prepare samples for high performance liquid chromatography (HPLC), centrifuge the solution from step 7.5 at 4,500 x g, remove the organic solvent layer, and dry the isopropanol:chloroform under a stream of nitrogen gas. Resuspend in 100 µL of 2:1 MeOH:H2O. Measure doxorubicin concentration using HPLC-MS/MS28.

8. Experiment: Mouse model imaging and sonication procedure for survival studies

NOTE: For survival studies, follow the HIFU treatment day animal preparation procedure (step 6.1 to 6.25).

  1. After completion of the treatment, place the mouse under a heat lamp to allow it to recover, and monitor its breathing and movement until it regains sternal recumbence. Then, return the animal to its cage.
    NOTE: Ensure half of the cage is in line with a heat lamp, as the thermal regulation of the animals is affected by the anesthesia and HT treatment.
  2. Monitor the mice daily for behavior, feeding patterns, and respiratory rate for any signs of distress.
  3. Perform treatments once weekly following steps 6.1 to 6.25 for 3 consecutive weeks.
  4. Twice weekly, perform MRI imaging of the mice for tumor measurement. For the weeks during treatment, perform one MRI scan and one ultrasound every week. After treatment is completed, perform biweekly ultrasound imaging.
  5. Euthanize the mouse 60 days after completing the series of treatments, or when a humane endpoint has been reached (tumor size >1.5 cm3 or morbidity from the tumor), followed by necropsy with tumor and organ removal for analysis.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

Using the MRgHIFU-generated hyperthermia protocol, the tumors in the hind limb were able to be consistently heated to the desired set temperature for the duration of the treatment (Figure 4 shows a representative treatment, 10 or 20 min, n = 65). To consider a treatment to be successful, the ROI had to be maintained above 39 °C for the entirety of the treatment, with <6 °C variation throughout the treatment and without heating of off-target tissue. Additionally, the core temperature had to remain below 39 °C, based on the rectal probe or the starting rectal temperature plus the change in the esophageal probe temperature (Supplemental Figure 2). Once the sonication of the MRgHIFU was stopped, the tumor rapidly returned to the baseline temperature.

The tumors were targeted to 40.5 °C to reach a temperature for rapid drug release while avoiding cumulative temperature effects above 43 °C. The average temperature of the ROI in all treated tumors was 40.6 °C (n = 65), with an average difference between the 10th percentile and 90th percentile voxels of 4.3 °C. The standard deviation of the average temperature was 1.3 °C for the duration of the treatment for both the 10 and 20 min treatments (Figure 5). The success rate of the treatments for meeting the inclusion criteria noticeably improved over the duration of the study from 11% to 100% (Figure 6).

After optimizing the treatment protocol, the duration of hyperthermia was assessed for drug release efficacy in comparison to normothermic (NT) mice. To determine the optimal hyperthermia treatment time for further studies, two durations of treatment were tested: 10 min and 20 min. These durations were selected for the feasibility of consistently maintaining core normothermia and tumor hyperthermia. High performance liquid chromatography and mass spectrometry (HPLC-MS) was used to assess the amount of doxorubicin in the tumors and quantify the difference of doxorubicin accumulation between the tested durations. There was a significantly higher percent of the initial dose (%ID) of doxorubicin in the tumors in the 20 min HT + TLD treated mice compared to the TLD 20 min NT mice (Figure 7, q = 0.000108). There was no significant difference between the 10 min and 20 min HT + TLD groups; however, there was a larger standard deviation in the 10 min treatment group compared to the 20 min group (3.698 vs. 2.065 %ID/g of tumor). Notably, there were four near-zero values within the 10 min HT + TLD treatment group, which were all treated with a single batch of TLD. TLD was characterized prior to use in in vivo experiments, as previously described by Dunne et al.28. Briefly, TLD was characterized in terms of its size, zeta potential, melting phase transition temperature, and drug concentration, and liposomes were used within 72 h of storage at 4 °C. Although all batches of TLD were tested prior to use, it is possible that the liposomes had released the doxorubicin during experimental setup, prior to use.In addition, motion during the scan can result in falsely elevated temperature calculations in the software, thus underheating the tumor and resulting in lower drug release. Alternatively, falsely low values could also be caused if the drug was never injected, for example, if the tail vein catheter had been removed or improperly placed. As seen above, the setup of the MRI sled included temperature probe insertion (rectal and esophageal), tail vein catheter insertion, and respiratory monitor placement, followed by moving of the sled, mouse, tail vein catheter, three fiber optic temperature probes, respiratory monitor, and anesthesia lines into the MRI bore. There are multiple time points during this process that the tail vein catheter can get dislodged. This was controlled for by checking blood back flow into the line, bleeding from the catheter insertion site, and drug pooling underneath the tape after treatment, but error remains a possibility.

Figure 1
Figure 1: Experimental protocol for animal treatments and the associated treatment groups for the HT duration studies. The mice were injected with M25FV24C cells in their right hind limb, and were screened for tumor formation using MRI after 2-3 weeks. They were then divided into normothermic (Non-HT) or hyperthermic (HT) groups, with either TLD or FD at durations of either 10 or 20 min. Abbreviation: Dox = Doxorubicin. Please click here to view a larger version of this figure.

Figure 2
Figure 2: Mouse setup during HIFU treatment. (A) A 3D printed holder (white) with inner rubber lining (red) and a cutout to allow for ultrasound beam passage for mouse positioning. (B) Mouse setup inside a 3D printed mouse holder with a rectal temperature hold (green cable), tail vein catheter (white), and respiratory monitor (blue). (C) Mouse positioning on the MRI HIFU bed during the procedure. Please click here to view a larger version of this figure.

Figure 3
Figure 3: Mouse in the MRI during MRIgHIFU treatment. (A) The tumor (circled in orange) and the drift tube used to measure ambient temperature (circled in light blue) are visible. (B) During treatment, the thermometry temperature measurement is overlaid on the MRI image. Please click here to view a larger version of this figure.

Figure 4
Figure 4: Temperature (°C) monitored during treatment. Average (green), top 10th percentile (red), and top 90th percentile (cyan) temperatures of all voxels in the ROI. Please click here to view a larger version of this figure.

Figure 5
Figure 5: Average temperatures during treatment within the ROI for each mouse tested during the optimization phase with the standard deviation during the treatment. The overall average temperature and standard deviation during treatment is also shown (orange). Please click here to view a larger version of this figure.

Figure 6
Figure 6: Success rates of hyperthermia treatment improved over time. Treatment success was dependent on the inclusion criteria (systemic temperature, tumor temperature and variation with the ROI, and no distal heating). Blue line = % of mice for which treatment was successful. Orange bars = number of mice treated with HT. Each treatment (treatment 1-6) refers to a separate date that the experiments were conducted on. Please click here to view a larger version of this figure.

Figure 7
Figure 7: Amount of doxorubicin in the tumor after drug treatment. (A) Multiple Mann-Whitney tests with FDR correction for multiple comparisons of the HPLC-MS results demonstrate significance (q < 0.05) between the amount of doxorubicin in the tumor in the 20 min TLD + HT group compared to the NT control. (B) No differences were seen in the tumor in the FD groups. %ID = percent of initial dose. **** = q < 0.0001. Abbreviations: HT = hyperthermia, NT = normothermia. Please click here to view a larger version of this figure.

Sequence Name Ax_Screen Ax_Loc Sag_Loc Cor_TestShot Therm
Sequence Type T2w RARE T2w RARE T2w RARE FLASH FLASH
Orientation Axial Axial Sagittal Coronal Axial/Sagittal
Echo time (ms) 40 72 72 6 6
Repetition time (ms) 3200 4500 4500 39.06 39.06
Flip angle (degrees) 90/180 90/180 90/180 10 10
Field-of-view (mm) 28.8 x 28.8 36 x 36 35 x 35 35 x 35
Matrix size 128 x 128 128 x 128 128 x 128 128 x 128 128 x 128
Resolution (mm) 0.225 x 0.225 0.281 x 0.281 0.281 x 0.281 0.273 x 0.273 0.273 x 0.273
Slice number 20 20 20 3 2
Slice thickness (mm) 1 1 1 1.5 1.25
# Averages 3 1 1 1 1
# Repetitions 1 1 1 9 9 or 300
Scan time 4 min 0 s 1 min 12 s 1 min 12 s 45 s 25 min

Table 1: Parameters for MRI capture with associated sequence names.

Supplemental Figure 1: A 3D model mouse holder (white) with inner rubber lining (red). Dimensions: length = 43 mm, outer radius = 15 mm, inner width = 20.7 mm. Please click here to download this File.

Supplemental Figure 2: Temperature (°C) monitored during treatment. Core temperature measured by rectal (blue) and esophageal (orange) probes. Please click here to download this File.

Supplemental Coding File 1: 3D printing file for the mouse holder. Please click here to download this File.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

The protocol developed herein was used to target hind limb tumors using MRgHIFU for mild HT treatment and release encapsulated drugs from liposomes in vivo. Several critical steps were encountered in this protocol during the pilot study, and optimizing these critical steps accounted for the improved treatment success over the pilot study. First is the complete removal of the hair on the area to be sonicated. Any gas trapping within the fur prevents the ultrasound beam from passing and blocks ultrasound passage into the target tissue1. Secondly, mouse positioning is vital to a successful treatment; the tumor should be placed superiorly in the mouse holder to be in closer contact with the ultrasound transducer. In addition, bony structures should be positioned out of the ultrasound beam path without injuring the mouse. Bone has been shown to absorb ultrasound waves efficiently, subsequently acting as an in situ heating source. It can affect the heating profile while blocking ultrasound transduction into the region of interest4. The contralateral limb should also be placed out of the way of the ultrasound path, either by tucking the leg up under the rest of the body or by extending it and filling the air between the legs with ultrasound gel or a gel pad. The rectum must also be out of the path of the ultrasound to avoid off-target heating and reflection from the temperature probe. Careful tumor positioning is the most important step to completing a successful treatment.

After correct positioning, placement of the esophageal temperature probe must be performed carefully to avoid tracheal occlusion. When inserting the mouse into the MRI bore, the metal connection hub between the catheter in the tail and the injection pump catheter should be secured with tape distal to the area of imaging to avoid artifact creation. The ultrasound transducer should be placed so that it is in contact with the fur-less area of the leg and not displacing the respiratory monitor. Careful monitoring of the mouse's core body temperature during treatment and subsequent adjustment of the convection heating system is required for mouse survival. Due to the proximity of the rectum and the tumor in some mice, the addition of the esophageal probe was important to determine core temperature change, as the rectal temperature could only reflect local heating as opposed to core body heating.

In designing and implementing this protocol, extensive troubleshooting was successfully executed by a multidisciplinary team. For mouse positioning, a mouse holder was designed and 3D printed to use on a rat MRI sled to allow for flow of the warmed air around the mouse for intra-procedural body temperature adjustment. The materials for this holder were chosen based on their ability to hold the mouse securely while allowing for ultrasound transduction. A rubber insert inside the printed holder allowed for individual mouse adjustments, while the cut out in the bottom prevented ultrasound wave reflection and unintended heating.

There are limitations associated with the model, such as the proximity of the tumors to nearby structures-bone (femur) and the rectum-which can absorb or reflect ultrasound waves, respectively. Unintentional heating of the femur can result in bone marrow destruction and pain, while ultrasound reflection from air in the rectum can cause local heating and tissue damage. Additionally, there were instances of trapping of the ultrasound wave due to skin regrowth after treatment in the survival mice, causing localized heating of the skin. It is suspected that this is due to air trapping around the hair follicle that is not displaced with the ultrasound gel between the transducer and the skin. In each case, the skin appeared darker than the surrounding hairless skin. On immunohistochemistry sections of these mouse limbs, hairs were seen within the epidermis, but no tumor fibrosis or other explanation was found for why the ultrasound would be unable to pass through the skin and subcutaneous tissues.

With the development of this protocol, further studies are planned to extend the model systems to test other pediatric solid tumors, such as osteosarcoma and myxofibrosarcoma, for treatment with HT and TLD. This is promising as these patients can face debilitating pain with limited treatment options in this clinical context. This protocol can be extended to other solid tumor types located in the extremities that are targetable with MRgHIFU29,30. In conclusion, the data supports that the combination of thermosensitive liposomes can be extrapolated to encapsulate other forms of chemotherapy or drugs where targeted drug delivery would be beneficial and having a noninvasive form of heating, such as MRgHIFU, would be ideal.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

The authors have no financial interests or conflicts of interest to disclose.

Acknowledgments

We would like to acknowledge our sources of funding for this project and the personnel involved including: C17 Research Grant, Canada Graduate Scholarship, Ontario Student Opportunity Trust Fund, and James J. Hammond Fund.

Materials

Name Company Catalog Number Comments
1.5mL Eppendorf tubes Eppendorf 22363204
1kb plus DNA Ladder Froggabio DM015-R500
2x HS-Red Taq (PCR mix) Wisent 801-200-MM
7 Tesla MRI BioSpec Bruker T184931 70/30 BioSpec, Bruker, Ettlingen, Germany
C1000 Thermal cycler Biorad 1851148
Clippers Whal Peanut 8655
Compressed ultrasound gel Aquaflex HF54-004
Convection heating device 3M Bair Hugger 70200791401
Depiliatory cream Nair 61700222611 Shopper's Drug Mart
DMEM Wisent 219-065-LK
DNeasy extraction kit Qiagen  69504
DPBS Wisent 311-420-CL
Drug injection system Harvard Apparatus PY2 70-2131 PHD 22/2200 MRI compatible Syringe Pump
Eye lubricant Optixcare 50-218-8442
F10 Media Wisent 318-050-CL
FBS Wisent 081-105
Froggarose FroggaBio A87
Gel Molecular Imager BioRad GelDocXR
Glutamax Wisent 609-065-EL
Heat Lamp Morganville Scientific HL0100  Similar to this product
Intravascular Polyethylene tubing (0.015" ID x 0.043" OD, 20G) SAI infusion PE-20-100
Isoflurane Sigma 792632
M25FV24C Cell line Gladdy Lab N/A
Microliter Syringe Hamilton 01-01-7648
Molecular Imager Gel Doc XR Biorad 170-8170
Mouse holder The 3D printing material used was ABS-M30i, and it was printed on FDM Fortus 380mc machine  N/A Dimensions: length = 43 mm, outer radius = 15 mm, inner width (where the mouse would sit) = 20.7 mm. 
MyRun Machine Cosmo Bio Co Ltd CBJ-IMR-001-EX
Nanodrop 8000 Spectrophotometer Thermo Scientific ND-8000-GL
p53 primers Eurofins N/A Custom Primers
PCR tubes Diamed SSI3131-06
Penicillin/Streptomycin Wisent 450-200-EL
Proteus software  Pichardo lab N/A
Respiratory monitoring system SAII Model 1030 MR-compatible monitoring and gating system for small animals
Small Bore HIFU device, LabFUS Image Guided Therapy N/A LabFUS, Image Guided Therapy, Pessac, France Number of elements 8
frequency 2.5 MHz
diameter  25 mm
radius of curvature 20 mm
Focal spot size 0.6 mm x 0.6 mm x 2.0 mm

Motor: axes 2

Generator:
Number of channels 8
Maximum electrical power/channel Wel 4
Maximum electrical power Wel 32
Bandwidth 0.5 - 5 MHz
Control per channel: Freq., Phase and. amplitude
Measurements per channel: Vrms, Irms, cos(theta)
Duty Cycle at 100% power % 100% for 1 min.

Transducer:
Number of elements 8
frequency  2.5 MHz
diameter 25 mm
radius of curvature 20 mm
Focal spot size  0.6 mm x 0.6 mm x 2.0 mm
SYBR Safe ThermoFisher Scientific S33102
TAE Wisent 811-540-FL
Tail vein catheter (27G 0.5" ) Terumo Medical Corp 15253
Thermal probes Rugged Monitoring L201-08
Trypan blue ThermoFisher Scientific 15250061
Trypsin Wisent 325-052-EL
Ultrasound Gel Aquasonic PLI 01-08

DOWNLOAD MATERIALS LIST

References

  1. Skapek, S. X., et al. Rhabdomyosarcoma. Nature Reviews Disease Primers. 5 (1), (2019).
  2. Ferrari, A., et al. Impact of rhabdomyosarcoma treatment modalities by age in a population-based setting. Journal of Adolescent and Young Adult Oncology. 10 (3), 309-315 (2021).
  3. Dasgupta, R. Pediatric rhabdomyosarcoma surgery: Background, anatomy, pathophysiology. , Available from: https://emedicine.medscape.com/article/939156-overview#a2 (2019).
  4. Ognjanovic, S., Linabery, A. M., Charbonneau, B., Ross, J. A. Trends in childhood rhabdomyosarcoma incidence and survival in the United States, 1975-2005. Cancer. 115 (18), 4218-4226 (2009).
  5. Mulrooney, D. A., et al. Cardiac outcomes in a cohort of adult survivors of childhood and adolescent cancer: retrospective analysis of the Childhood Cancer Survivor Study cohort. BMJ. 339, (2009).
  6. Lipshultz, S. E., Cochran, T. R., Franco, V. I., Miller, T. L. Treatment-related cardiotoxicity in survivors of childhood cancer. Nature Reviews Clinical Oncology. 10 (12), 697-710 (2013).
  7. Winter, S., Fasola, S., Brisse, H., Mosseri, V., Orbach, D. Relapse after localized rhabdomyosarcoma: Evaluation of the efficacy of second-line chemotherapy. Pediatric Blood & Cancer. 62 (11), 1935-1941 (2015).
  8. Wood, B. J., et al. Phase I study of heat-deployed liposomal doxorubicin during radiofrequency ablation for hepatic malignancies. Journal of Vascular and Interventional Radiology. 23 (2), 248-255 (2012).
  9. Bulbake, U., Doppalapudi, S., Kommineni, N., Khan, W. Liposomal formulations in clinical use: an updated review. Pharmaceutics. 9 (2), 12 (2017).
  10. Zagar, T. M., et al. Two phase I dose-escalation/pharmacokinetics studies of low temperature liposomal doxorubicin (LTLD) and mild local hyperthermia in heavily pretreated patients with local regionally recurrent breast cancer. International Journal of Hyperthermia. 30 (5), 285-294 (2014).
  11. Kim, A. A phase I study of lyso-thermosensitive liposomal doxorubicin and MR-HIFU for pediatric refractory solid tumors. , Available from: https://clinicaltrials.gov/ct2/show/NCT02536183 (2019).
  12. PanDox: targeted doxorubicin in pancreatic tumours (PanDox). University of Oxford. , Available from: https://clinicaltrials.gov/ct2/show/NCT04852367 (2021).
  13. Suelmann, B. B. M. Image-guided targeted doxorubicin delivery with hyperthermia to optimize loco-regional control in breast cancer (i-GO). , Available from: https://clinicaltrials.gov/ct2/show/NCT03749850 (2018).
  14. De Vita, A., et al. Lysyl oxidase engineered lipid nanovesicles for the treatment of triple negative breast cancer. Scientific Reports. 11 (1), 5107 (2021).
  15. Sapareto, S. A., Dewey, W. C. Thermal dose determination in cancer therapy. International Journal of Radiation Oncology, Biology, Physics. 10 (6), 787-800 (1984).
  16. Kok, H. P., et al. Heating technology for malignant tumors: a review. International Journal of Hyperthermia. 37 (1), 711-741 (2020).
  17. Kokuryo, D., Kumamoto, E., Kuroda, K. Recent technological advancements in thermometry. Advanced Drug Delivery Reviews. 163, 19-39 (2020).
  18. Bongiovanni, A., et al. 3-T magnetic resonance-guided high-intensity focused ultrasound (3 T-MR-HIFU) for the treatment of pain from bone metastases of solid tumors. Support Care Cancer. 30 (7), 5737-5745 (2022).
  19. Seifert, G., et al. Regional hyperthermia combined with chemotherapy in paediatric, adolescent and young adult patients: current and future perspectives. Radiation Oncology. 11, 65 (2016).
  20. Dewhirst, M. W., Lee, C. -T., Ashcraft, K. A. The future of biology in driving the field of hyperthermia. International Journal of Hyperthermia. 32 (1), 4-13 (2016).
  21. Dewhirst, M. W., Vujaskovic, Z., Jones, E., Thrall, D. Re-setting the biologic rationale for thermal therapy. International Journal of Hyperthermia. 21 (8), 779-790 (2005).
  22. Repasky, E. A., Evans, S. S., Dewhirst, M. W. Temperature matters! And why it should matter to tumor immunologists. Cancer Immunology Research. 1 (4), 210-216 (2013).
  23. Hijnen, N., et al. Thermal combination therapies for local drug delivery by magnetic resonance-guided high-intensity focused ultrasound. Proceedings of the National Academy of Sciences. 114 (24), E4802-E4811 (2017).
  24. Shultz, L. D., et al. Human cancer growth and therapy in immunodeficient mouse models. Cold Spring Harbor Protocols. 2014 (7), 694-708 (2014).
  25. De Vita, A., et al. Deciphering the genomic landscape and pharmacological profile of uncommon entities of adult rhabdomyosarcomas. International Journal of Molecular Sciences. 22 (21), 11564 (2021).
  26. McKinnon, T., et al. Functional screening of FGFR4-driven tumorigenesis identifies PI3K/mTOR inhibition as a therapeutic strategy in rhabdomyosarcoma. Oncogene. 37 (20), 2630-2644 (2018).
  27. Zaporzan, B., et al. MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU. Journal of Therapeutic Ultrasound. 1, (2013).
  28. Dunne, M., et al. Heat-activated drug delivery increases tumor accumulation of synergistic chemotherapies. Journal of Controlled Release. 308, 197-208 (2019).
  29. Zhao, Y. X., Hu, X. Y., Zhong, X., Shen, H., Yuan, Y. High-intensity focused ultrasound treatment as an alternative regimen for myxofibrosarcoma. Dermatologic Therapy. 34 (2), 14816 (2021).
  30. Vanni, S., et al. Myxofibrosarcoma landscape: diagnostic pitfalls, clinical management and future perspectives. Therapeutic Advances in Medical Oncology. 14, 17588359221093973 (2022).

Tags

Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia Preclinical Testing Tumor Targeted Hyperthermia Thermo Sensitive Drugs Survival Improvement Systemic Toxicity Reduction Sarcoma Treatment Chemotherapy Release Confinement Localized Hypothermia Immune System Activation Cancer Targeting Standard Chemotherapy MRI Physicist HIFU Physicist Master's Graduate In Applied Science Mouse Shaving Cell Suspension Injection

Erratum

Formal Correction: Erratum: Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Posted by JoVE Editors on 02/08/2023. Citeable Link.

An erratum was issued for: Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model . The Authors section was updated from:

Claire Wunker1,2
Karolina Piorkowska3
Ben Keunen3
Yael Babichev2
Suzanne M. Wong3,4
Maximilian Regenold5
Michael Dunne5
Julia Nomikos1,2
Maryam Siddiqui6
Samuel Pichardo6
Warren Foltz7
Adam C. Waspe3,8
Justin T. Gerstle3,9
Rebecca A. Gladdy1,2,10
1 Institute of Medical Science, University of Toronto
2 2Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital
3 The Wilfred and Joyce Posluns Centre for Image-Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children
4 Institute of Biomedical Engineering, University of Toronto
5 Leslie Dan Faculty of Pharmacy, University of Toronto
6 Departments of Radiology and Clinical Neurosciences, University of Calgary
7 Department of Radiation Oncology, University of Toronto
8 Department of Medical Imaging, University of Toronto
9 Department of Pediatric Surgery, University of Toronto
10 Department of Surgery, University of Toronto

to:

Claire Wunker1,2
Karolina Piorkowska3
Ben Keunen3
Yael Babichev2
Suzanne M. Wong3,4
Maximilian Regenold5
Michael Dunne5
Julia Nomikos1,2
Maryam Siddiqui6
Samuel Pichardo6
Warren Foltz7
Adam C. Waspe3,8
Justin T. Gerstle3,9
James M. Drake1,3,4,10
Rebecca A. Gladdy1,2,10
1 Institute of Medical Science, University of Toronto
2 Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital
3 The Wilfred and Joyce Posluns Centre for Image-Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children
4 Institute of Biomedical Engineering, University of Toronto
5 Leslie Dan Faculty of Pharmacy, University of Toronto
6 Departments of Radiology and Clinical Neurosciences, University of Calgary
7 Department of Radiation Oncology, University of Toronto
8 Department of Medical Imaging, University of Toronto
9 Department of Pediatric Surgery, University of Toronto
10 Department of Surgery, University of Toronto

Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Wunker, C., Piorkowska, K., Keunen,More

Wunker, C., Piorkowska, K., Keunen, B., Babichev, Y., Wong, S. M., Regenold, M., Dunne, M., Nomikos, J., Siddiqui, M., Pichardo, S., Foltz, W., Waspe, A. C., Gerstle, J. T., Drake, J. M., Gladdy, R. A. Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model. J. Vis. Exp. (191), e64544, doi:10.3791/64544 (2023).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter