The standardization of flow cytometry is useful for the comparability of results obtained from different cytometers across different laboratories and study centers, and conducive to the mutual recognition of results to improve work efficiency. An increasing number of scenarios require standardization. During the drug development process, flow cytometry standardization is important, as a developed and validated assay will support the whole drug development process from preclinical to clinical analysis. Flow cytometric methods are frequently transferred between the pharmaceutical industry and collaborating laboratories1. Moreover, it is essential to obtain comparable data from multicentric clinical studies. For example, a standardization workflow was developed in the Systemic Autoimmune Diseases Multicenter Clinical Research Project to obtain comparable data from multicentric flow cytometry2.
The standardization of flow cytometry methods is challenging. The challenges experienced across labs are attributed to the lack of standardized materials, software compatibility issues, inconsistencies in instrument setup, and the use of different configurations among different flow cytometers and divergent gating strategies between the centers3,4. Therefore, it is important to conduct a gap analysis between laboratories. Sample access, quality systems, personnel qualifications, and instrument configuration must be reviewed to ensure that the requirements are met.
At present, children vaccinated with the Japanese encephalitis (JE) vaccine have a significantly reduced incidence of JE5. Monitoring peripheral blood immune cells can help understand the changes in cell-mediated adaptive immunity after vaccination, and the correlation between the changes in peripheral blood lymphocyte subsets and the effects of vaccination. Due to the limited stability of whole blood samples, evaluations of vaccine efficacy are often performed in multiple centers. For this analysis, we defined naïve CD8+ or CD4+ T cells as CD27+ CD45RA+, central memory T cells (TCM) as CD27+ CD45RA-, effector memory T cells (TEM) as CD27- CD45RA-, and terminally differentiated effector memory T cells (TEMRA) as CD27- CD45RA+. CD19+ B cells can be separated into populations that express CD27 versus IgD6,7, naïve B cells express CD27n memory B cells (mBCs) can be identified based on the expression of IgD6, and regulatory T cells (Tregs) can be identified as CD4+CD25++CD127low 8. To establish a standardized flow cytometry experiment to achieve the consistency and comparability of experimental results in multiple centers, a rapid and feasible standardization method was established to facilitate the transfer of protocols across different flow cytometers for the detection of lymphocytes in the whole blood of JE-vaccinated children. Six healthy children (2 years old) were recruited from Beijing Children's Hospital, Capital Medical University. After receiving a prime and boost vaccination with a live-attenuated JE SA14-14-2 vaccine less than 6 months prior, peripheral blood samples were collected from the volunteers. Highly comparable data were obtained from different instruments following standardized procedures, which is helpful for multicenter assessments.