Continuous Arterial Pressure Monitoring in Conscious Rodents Using Implantable Telemetry and Comparison with the Tail-Cuff Method

994 views

⸱

DOI:

10.3791/69652

⸱

November 14th, 2025

In This Article

Summary

This protocol details the application of implantable telemetry for continuous and reliable arterial pressure monitoring in conscious rodents, covering surgical implantation, postoperative care, data acquisition, and comparison with the tail-cuff method.

Abstract

Radio telemetry enables reliable, continuous arterial blood pressure (BP) monitoring in conscious rodents under physiological conditions, while minimizing operator-related artifacts. The implantable transmitter includes a pressure-sensing catheter, and the implantation procedure varies depending on the species used and the purpose of the study. In rodents, the most common approaches are implantation through the carotid artery or the abdominal aorta. The carotid artery approach is often favored for its direct path to the aortic arch, facilitating accurate central pressure measurement, while the abdominal aorta approach is also widely utilized for chronic studies. Compared with non-invasive methods such as tail-cuff, implantable telemetry provides more accurate and consistent measurements, making it especially useful for hypertension studies that require precise long-term BP monitoring. This protocol details anesthesia, surgical implantation techniques, and postoperative care, as well as procedures for acquiring and analyzing hemodynamic parameters-systolic, diastolic, and mean arterial pressure and heart rate (HR)-together with a comparative evaluation against tail-cuff measurements.

Introduction

Accurate and continuous monitoring of arterial blood pressure (BP) in conscious rodents is essential for cardiovascular research, especially in hypertension studies where dynamic hemodynamic changes require precise measurement1,2,3. Traditional non-invasive methods, such as the tail-cuff method, are widely used but limited by intermittent sampling, stress-related artifacts, and failure to capture circadian BP variations4,5. These issues compromise accuracy and reproducibility, restricting their use in long-term hemody....

Access restricted. Please log in or start a trial to view this content.

Protocol

All experimental procedures were approved by the Institutional Animal Care and Use Committee (IACUC) of Xi'an Jiaotong University (No. XJTUAE2025-2784) and were conducted in accordance with institutional and national guidelines for the care and use of laboratory animals. Eight-week-old male spontaneously hypertensive rats (SHRs) and C57BL/6 mice were used in the experiments.

1. Animal preparation

  1. Housing conditions: House all animals in environmentally controlled rooms. Maintain an ambient temperature of 21 °C and a relative humidity of 60%. Set a 12 h light/12 h dark cycle. Provide standard laboratory ....

Access restricted. Please log in or start a trial to view this content.

Results

Continuous telemetric recording of BP and HR in C57BL/6 Mice
Eight-week-old male C57BL/6 mice were randomized to undergo transmitter implantation by carotid artery cannulation (CAC) or abdominal aorta cannulation (AAC). After 10 days of recovery, baseline BP was recorded. Continuous 24 h monitoring confirmed stable and reliable signals with the expected circadian rhythm, showing slightly higher nocturnal than diurnal values. Compared with CAC, AAC resulted in higher SBP (Figure 8.......

Access restricted. Please log in or start a trial to view this content.

Discussion

Critical steps within the protocol
Implantable telemetry is widely recognized as the gold standard for continuous, high-fidelity cardiovascular monitoring in conscious, freely moving rodents31,32. A critical step is the selection of the catheter implantation site, either the carotid artery or the abdominal aorta, based on experimental goals. Carotid artery implantation offers technical simplicity and allows catheter advancement into the asc.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported by the Natural Science Foundation of China (grant 82230012, 81830015 to N. Wang, grant 91939108, 82570478 to L. Xiao).

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
APR-1 Ambient Pressure ReferenceData Sciences International (DSI)The APR-1 Ambient Pressure Reference is a required component of each DSI telemetry system where pressure measurements are being monitored in order to dynamically compensate for the effects change in barometric pressure has on the absolute (relative to vacuum) measurements taken by the telemetry implants
Cellulose patch kitData Sciences International (DSI)370-0036-001
GlutaraldehydeMetriCide89132-856
Graefe Forceps-curved, with teethData Sciences International (DSI)11054-10
Implant(HD-S10)Data Sciences International (DSI)825969
Implant(HD-S10)Data Sciences International (DSI)910265
Implant(HD-X11)Data Sciences International (DSI)1315981
Implant(HD-X11)Data Sciences International (DSI)1315986
isofluraneRWD Life ScienceR510-22-10
Lexar-Baby Scissors-straight, 10 cmData Sciences International (DSI)14078-10
Matrix 2.0 (MX2) Data Sciences International (DSI)The Matrix 2.0 (MX2) manages communication between PhysioTel and PhysioTel HD telemetry implants and the acquisition computer.
Moria Instrument CaseData Sciences International (DSI)20311-21
Normal SalineKelong PharmaceuticalC1250213B1
Olsen-Hegar Needle Holder-extra delicateData Sciences International (DSI)12002-12
pentobarbital sodiumSigma-AldrichP3761
RPC-1 receiversData Sciences International (DSI)34668The RPC-1 receiver is most often used for monitoring animals housed in plastic cages that can be placed on top of the receiver. The RPC-1 receiver provides reliable reception of data transmitted via digital telemetry and has two receiving antennae oriented at right angles to minimize dropouts due to directionality of the transmission pattern.
RPC-1 receiversData Sciences International (DSI)34669
TergazymeSigma-AldrichZ273287
Vessel Cannulation Forceps, 11 cm longData Sciences International (DSI)00608-11
Vessel Dilator-45 degree angled tip, 13.5 cm longData Sciences International (DSI)00276-13
Vetbond Tissue AdhesiveMinnesota Mining and Manufacturing Company (3M)1469SB
Xylazine 20Sigma-AldrichX1251
Zoletil 50Virbac Laboratories

References

  1. Van Vliet, B. N., Chafe, L. L., Montani, J. P. Characteristics of 24 h telemetered blood pressure in enos-knockout and c57bl/6j control mice. J Physiol. 549 (Pt 1), 313-325 (2003).
  2. Braga, V. A., Prabhakar, N. R. Refinement of telemetry for meas....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Tags

Blood Pressure MeasurementCarotid ArteryAbdominal AortaHypertension StudiesHemodynamic ParametersSurgical Implantation